Crowbar Protection Scheme for Fault Ride Through in a Doubly-fed Induction Generator

被引:2
|
作者
Seth, Sarthak [1 ]
Tharani, Kusum [1 ]
Banerjee, Sandeep [1 ]
Chhabra, Chaitanya [1 ]
Verma, Anshika [1 ]
Bhatia, Mridul [1 ]
机构
[1] Bharati Vidyapeeths Coll Engn, Elect & Elect Engn Dept, New Delhi, India
关键词
Doubly fed induction generator; dynamic crowbar protection; environment; fault ride through; pollution; symmetrical voltage dips;
D O I
10.3233/AJW230063
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study focusses on using a crowbar protection scheme to overcome the symmetrical voltage dips in a doubly fed induction generator (DFIG). The crowbar protection scheme is integrated into the wind energy conversion system of the DFIG. The implementation of this scheme provides automated fault ride-through during sudden transients which may otherwise lead to over current faults. The increased use of renewable sources for electricity generation leads to a reduction in pollution which directly benefits the environment. Sustained usage of renewable resources will be beneficial for the environment.
引用
收藏
页码:33 / 37
页数:5
相关论文
共 50 条
  • [1] Fault Ride-Through of Doubly-Fed Induction Generator with Converter Protection Schemes
    Yang, Jin
    Dorrell, David G.
    Fletcher, John E.
    [J]. 2008 IEEE INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY TECHNOLOGIES (ICSET), VOLS 1 AND 2, 2008, : 1211 - +
  • [2] Comprehensive fault ride-through scheme for doubly-fed induction generators
    Cheng, Fan
    Yao, Liangzhong
    Li, Yan
    Xie, Lijun
    Wei, Chunxia
    [J]. JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2468 - 2473
  • [3] A fault ride through scheme for doubly fed induction generator wind turbine
    [J]. Ling, Yu (pleasurely@126.com), 2018, Taylor and Francis Ltd. (15):
  • [4] An improved fault current calculation method and protection scheme of Doubly-fed Induction Generator
    Yin, Jun
    [J]. ENERGY REPORTS, 2021, 7 : 5168 - 5174
  • [5] Fault-Current Study of the Wind-Turbine-Driven Doubly-Fed Induction Generator with the Crowbar Protection
    Kong, Xiangping
    Zhang, Zhe
    [J]. ELEKTROTEHNISKI VESTNIK-ELECTROCHEMICAL REVIEW, 2014, 81 (1-2): : 57 - 63
  • [6] A Doubly-Fed Induction Generator Test Facility for Grid Fault Ride-Through Analysis
    Atkinson, David
    Pannell, Graham
    Cao, Wenping
    Zahawi, Bashar
    Abeyasekera, Tusitha
    Jovanovic, Milutin
    [J]. IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2012, 15 (06) : 20 - 27
  • [7] Fault ride through capability of doubly-FED induction generator wind power generation system
    Ma, Hongfei
    Xu, Dianguo
    Chen, Zhe
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2009, 30 (10): : 1228 - 1233
  • [8] Protection Scheme Switch-Timing for Doubly-Fed Induction Generator during Fault Conditions
    Yang, Jin
    O'Reilly, John
    Fletcher, John E.
    [J]. 2009 IEEE BUCHAREST POWERTECH, VOLS 1-5, 2009, : 1295 - +
  • [9] Improvement of Fault Ride Through Capability of Doubly-Fed Induction Generator Wind Turbines with Hysteresis Controller
    Ling, Yu
    [J]. WIND ENGINEERING, 2014, 38 (06) : 659 - 672
  • [10] Modeling and Fault Characteristics Analysis of Doubly Fed Induction Generator Incorporating Crowbar Protection
    Ali, Arshad
    Larik, Nauman Ali
    Tahir, Muhammad Faizan
    Abbassi, Rabeh
    Jerbi, Houssem
    Mehmood, Kashif
    [J]. JOURNAL OF ELECTRICAL SYSTEMS, 2020, 16 (03) : 393 - 410