A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support

被引:2
|
作者
Shen Yang-Wu [1 ]
Ke De-Ping [1 ]
Sun Yuan-Zhang [1 ]
Kirschen, Daniel [2 ]
Wang Yi-Shen [2 ]
Hu Yuan-Chao [1 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
[2] Univ Washington, Dept Elect Engn, Seattle, WA 98195 USA
基金
中国国家自然科学基金;
关键词
doubly-fed induction generator; transient rotor current control; superconducting magnetic energy storage; voltage support; RIDE-THROUGH STRATEGY; DFIG WIND TURBINES;
D O I
10.1088/1674-1056/24/7/070201
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator (DFIG) equipped with a superconducting magnetic energy storage (SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter (GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter (RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive (priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Control of A Doubly-Fed Induction Generator for Wind Energy Conversion System
    Boubzizi, Said
    El Hajjaji, Ahmed
    Abid, Hafedh
    Chaabane, Mohamed
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 8773 - 8778
  • [22] Transient Voltage Stability Analysis of Doubly-fed Induction Generator Based on Singularity Principle
    Zhang, Jianxin
    Yang, Huanhuan
    Qiu, Jian
    Xv, Guanghu
    Gao, Qin
    Jiang, Tuo
    Li, Peng
    Chen, Jvnquan
    Li, Jiqi
    Ke, Deping
    2023 3rd International Conference on Energy Engineering and Power Systems, EEPS 2023, 2023, : 63 - 68
  • [23] An Improved Droop Control Scheme of a Doubly-Fed Induction Generator for Various Disturbances
    Xu, Yien
    Chen, Pei
    Zhang, Xinsong
    Yang, Dejian
    ENERGIES, 2021, 14 (23)
  • [24] Control strategy of doubly-fed induction generator during the grid voltage swell
    Zou Le
    Wu Xueguang
    Kou Longze
    Liu Dong
    Li Fangyuan
    Han Mingxiao
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 1807 - 1811
  • [25] Wind turbine system with Doubly-Fed Induction Generator and rotor power feedback control
    Faculty of Electrical Engineering Mechanical Engineering and Naval Architecture, University in Split, Rudjera Boskovica bb, 21000 Split, Croatia
    WSEAS Trans. Syst., 2006, 12 (2860-2867):
  • [26] The Influence of Rotor Arrester on Low Voltage Ride Through Behavior of Doubly-Fed Induction Generator
    Chen, Chen
    Wang, Ruiming
    Zhang, Jinping
    PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 719 - 722
  • [27] Robust Disturbance Rejection Rotor Current Control of Doubly-Fed Induction Generators
    Penne, Matthew
    Jia, Chao
    Qiao, Wei
    Qu, Liyan
    Wang, Shaobu
    Chen, Yousu
    Qu, Lizhi
    Huang, Renke
    Huang, Qiuhua
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (03) : 4302 - 4312
  • [28] Wide Speed Operation of a Doubly-fed Induction Generator for Tidal Current Energy
    Park, J. W.
    Lee, K. W.
    Lee, H. J.
    IECON 2004: 30TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOL 2, 2004, : 1333 - 1338
  • [29] New control scheme for doubly-fed induction generators to improve transient stability
    La Seta, Piergiovanni
    Schegner, Peter
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 1353 - 1362
  • [30] Direct Stator Current Phase Control strategy of Doubly-fed Induction Generator
    Zhe, Li
    Ge, Li
    Zheng, Gao
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 2408 - 2411