Refrigerant migration during startup of a split air conditioner in heating mode

被引:21
|
作者
Han, Binglong [1 ]
Yan, Gang [1 ]
Yu, Jianlin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Shaanxi, Peoples R China
关键词
Refrigerant mass distribution; Supply air temperature; Heating capacity; Control method; Room air conditioner; INDOOR THERMAL COMFORT; COMPRESSOR; OPERATION; PRESSURE; SYSTEMS; R-410A; R290;
D O I
10.1016/j.applthermaleng.2018.11.126
中图分类号
O414.1 [热力学];
学科分类号
摘要
During winters, room air conditioners are generally expected to supply occupants with hot air rapidly following startup. In this study, the refrigerant migration characteristics during startup of a split air conditioner were experimentally investigated in heating mode. The transient refrigerant distribution inside main components was measured by using the quick-closing valve technique. The high and low side pressures and temperatures of the system were also investigated under the given operating conditions. All experiments were carried out in psychrometric rooms. On this basis, two control methods during the startup and shutdown process were proposed and tested. It was verified that increasing the refrigerant mass in the condenser prior to restarting can benefit the establishment of high pressure and supply occupants with air at a comfortable temperature more rapidly.
引用
收藏
页码:1068 / 1073
页数:6
相关论文
共 50 条
  • [41] Evaporative characteristics of refrigerant R410A in air-conditioner systems
    Duan, X. T.
    Xue, Y. Q.
    Wang, F.
    Wu, Z. M.
    Rui, S. J.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 560 - 564
  • [42] MODELING OF A SOLAR-OPERATED ABSORPTION AIR CONDITIONER SYSTEM WITH REFRIGERANT STORAGE
    GRASSIE, SL
    SHERIDAN, NR
    SOLAR ENERGY, 1977, 19 (06) : 691 - 700
  • [43] Modeling of a split type air conditioner with integrated water heater
    Techarungpaisan, P.
    Theerakulpisut, S.
    Priprem, S.
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (04) : 1222 - 1237
  • [44] An empirical model for simulating the effects of refrigerant charge faults on air conditioner performance
    Cheung, Howard
    Braun, James E.
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (05) : 776 - 786
  • [45] Experimental study on operating characteristics of split air conditioning system during rapid leakage of refrigerant
    Zhang S.-Z.
    Fang J.-H.
    Liang L.-Y.
    Li Z.-T.
    Chen G.-M.
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2023, 57 (10): : 2086 - 2093
  • [46] Fast dynamic simulation of a split unit domestic air conditioner
    Ding, GL
    Zhang, CL
    Li, H
    Chen, ZJ
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR 98, 1998, : 282 - 285
  • [47] Study on structure optimization and distribution characteristics of centrifugal refrigerant distributor for air conditioner
    Tang, Qingqing
    Dai, Yuande
    Pan, Chuang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 156 : 123 - 132
  • [48] Numerical Simulation of Internal Flow of an Indoor Machine of a Split-Type Air Conditioner in Isothermal and Refrigerant Operating Condition Based on CFD Technology
    Xue Yongfei
    Wang Yinghui
    Gan Jiaye
    Wu Keqi
    ITESS: 2008 PROCEEDINGS OF INFORMATION TECHNOLOGY AND ENVIRONMENTAL SYSTEM SCIENCES, PT 1, 2008, : 791 - 798
  • [49] The Impact of Hydrocarbon R290 Refrigerant on Air Conditioner Performance and Environmental Sustainability
    Khai, Ferdinand Ng Siek
    Zakaria, Nurul Sabihah
    PERTANIKA JOURNAL OF SCIENCE AND TECHNOLOGY, 2025, 33 (02): : 1069 - 1087
  • [50] Refrigerant leakage detection in an EEV installed residential air conditioner with limited sensor installations
    Yoo, Jin Woo
    Bin Hong, Sung
    Kim, Min Soo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 78 : 157 - 165