Refrigerant migration during startup of a split air conditioner in heating mode

被引:21
|
作者
Han, Binglong [1 ]
Yan, Gang [1 ]
Yu, Jianlin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Shaanxi, Peoples R China
关键词
Refrigerant mass distribution; Supply air temperature; Heating capacity; Control method; Room air conditioner; INDOOR THERMAL COMFORT; COMPRESSOR; OPERATION; PRESSURE; SYSTEMS; R-410A; R290;
D O I
10.1016/j.applthermaleng.2018.11.126
中图分类号
O414.1 [热力学];
学科分类号
摘要
During winters, room air conditioners are generally expected to supply occupants with hot air rapidly following startup. In this study, the refrigerant migration characteristics during startup of a split air conditioner were experimentally investigated in heating mode. The transient refrigerant distribution inside main components was measured by using the quick-closing valve technique. The high and low side pressures and temperatures of the system were also investigated under the given operating conditions. All experiments were carried out in psychrometric rooms. On this basis, two control methods during the startup and shutdown process were proposed and tested. It was verified that increasing the refrigerant mass in the condenser prior to restarting can benefit the establishment of high pressure and supply occupants with air at a comfortable temperature more rapidly.
引用
收藏
页码:1068 / 1073
页数:6
相关论文
共 50 条
  • [21] Experimental research on the explosion characteristics in the indoor and outdoor units of a split air conditioner using the R290 refrigerant
    Zhang, Wang
    Yang, Zhao
    Zhang, Xin
    Lv, Dong
    Jiang, Nan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 67 : 408 - 417
  • [22] Optimization study on the structure and the flow of a refrigerant distributor for air conditioner
    Zhang, Derun
    Pu, Liang
    Nian, Luozhu
    Meng, Zhongyi
    Gu, Tangtang
    Liu, Min
    Zhou, Yachen
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 (131) : 847 - 856
  • [23] Optimal Refrigerant by Integrated Operational and Environmental Criteria in Air Conditioner
    Mutlag, Sattar A.
    Dawood, H. K.
    12TH INTERNATIONAL CONFERENCE ON THE DEVELOPMENTS IN ESYSTEMS ENGINEERING (DESE 2019), 2019, : 309 - 314
  • [24] Simulated and experimental performance of split packaged air conditioner using refrigerant HC-290 as a substitute for HCFC-22
    Padalkar, Atul S.
    Mali, Kundlik V.
    Devotta, Sukumar
    APPLIED THERMAL ENGINEERING, 2014, 62 (01) : 277 - 284
  • [25] Greenhouse Gas Emissions for Refrigerant Choices in Room Air Conditioner Units
    Galka, Michael D.
    Lownsbury, James M.
    Blowers, Paul
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (23) : 12977 - 12985
  • [26] CAPACITY ASSESSMENT OF A WINDOW AIR-CONDITIONER RETROFITTED WITH A REFRIGERANT MIXTURE
    Raj, M. Herbert
    Laly, D. Mohan
    Jabaraj, D. B.
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2011, 19 (01) : 69 - 84
  • [27] Research on the compression method for domestic air conditioner with water vapor as the refrigerant
    Xing, Xue
    Sheng, Li
    An, Wang
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON MATERIALS SCIENCE, MACHINERY AND ENERGY ENGINEERING (MSMEE 2017), 2017, 123 : 1209 - 1215
  • [28] Simulation of variable refrigerant flow air conditioning system in heating mode combined with outdoor air processing unit
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    Fan, Bo
    Fang, Xing
    ENERGY AND BUILDINGS, 2014, 68 : 571 - 579
  • [29] Performance Analysis of the Electric Vehicle Air Conditioner by Replacing Hydrocarbon Refrigerant
    Santoso, Budi
    Tjahjana, D. D. D. P.
    INTERNATIONAL CONFERENCE ON ENGINEERING, SCIENCE AND NANOTECHNOLOGY 2016 (ICESNANO 2016), 2017, 1788
  • [30] Influence of porous condenser on the performance of a split air conditioner
    Mohammad Tarawneh
    Ahmad Bani Yaseen
    Journal of Thermal Analysis and Calorimetry, 2022, 147 : 15033 - 15041