Uteroplacental and Fetal 4D Flow MRI in the Pregnant Rhesus Macaque

被引:19
|
作者
Macdonald, Jacob A. [1 ]
Corrado, Philip A. [1 ]
Nguyen, Sydney M. [2 ]
Johnson, Kevin M. [1 ]
Francois, Christopher J. [3 ]
Magness, Ronald R. [4 ]
Shah, Dinesh M. [5 ]
Golos, Thaddeus G. [2 ,6 ]
Wieben, Oliver [1 ,3 ]
机构
[1] Univ Wisconsin, Dept Med Phys, 1530 Med Sci Ctr, Madison, WI 53706 USA
[2] Univ Wisconsin, Wisconsin Natl Primate Ctr, Madison, WI USA
[3] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[4] Univ S Florida, Dept Obstet & Gynecol, Tampa, FL USA
[5] Univ Wisconsin, Dept Obstet & Gynecol, Madison, WI 53706 USA
[6] Univ Wisconsin, Dept Comparat Biosci, 2015 Linden Dr W, Madison, WI 53706 USA
基金
美国国家卫生研究院;
关键词
BLOOD-FLOW; UTERINE ARTERIES; ULTRASOUND; RESISTANCE; PREECLAMPSIA; RESOLUTION; OVARIAN;
D O I
10.1002/jmri.26206
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Pregnancy complications are often associated with poor uteroplacental vascular adaptation and standard diagnostics are unable to reliably quantify flow in all uteroplacental vessels and have poor sensitivity early in gestation. Purpose To investigate the feasibility of using 4D flow MRI to assess total uteroplacental blood flow in pregnant rhesus macaques as a precursor to human studies. Study Type Retrospective feasibility study. Animal Model Fifteen healthy, pregnant rhesus macaques ranging from the 1(st) trimester to 3(rd) trimester of gestation. Field Strength/Sequence Abdominal 4D flow MRI was performed on a 3.0T scanner with a radially undersampled phase contrast (PC) sequence. Reference ferumoxytol-enhanced angiograms were acquired with a 3D ultrashort echo time sequence with a center-out radial trajectory. Assessment Repeatability of flow measurements was assessed with scans performed same-day and on consecutive days in the uterine arteries and ovarian veins. In-flow was compared against out-flow in the uterus, umbilical cord, and fetal heart with a conservation of mass analysis. Conspicuity of uteroplacental vessels was qualitatively compared between PC angiograms derived from 4D flow data and ferumoxytol-enhanced angiograms. Statistical Tests Bland-Altman analysis was used to quantify same-day and consecutive-day repeatability. Results Same-day flow measurements showed an average difference between scans of 13% in both the uterine arteries and ovarian veins, while consecutive-day measurements showed average differences of 22% and 24%, respectively. Comparisons of in-flow and out-flow showed average differences of 15% in the uterus, 8% in fetal heart, and 15% in the umbilical cord. PC angiograms showed similar depiction of main uteroplacental vessels as high-resolution, ferumoxytol-enhanced angiograms. Data Conclusion 4D flow MRI could be used in the rhesus macaque for repeatable flow measurements in the uteroplacental and fetal vasculature, setting the stage for future human studies. Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:534-545.
引用
收藏
页码:534 / 545
页数:12
相关论文
共 50 条
  • [1] Ultrasound evaluation of normal rhesus macaque fetal biometry and uteroplacental hemodynamics
    D'Mello, Rahul J.
    Lo, Jamie O.
    Hagen, Olivia L.
    Castro, Jenna N.
    Graham, Jason A.
    Frias, Antonio E.
    Roberts, Victoria H. J.
    AMERICAN JOURNAL OF PRIMATOLOGY, 2023, 85 (07)
  • [2] 4D Flow with MRI
    Soulat, Gilles
    McCarthy, Patrick
    Markl, Michael
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, VOL 22, 2020, 22 : 103 - 126
  • [3] 4D flow MRI
    Markl, Michael
    Frydrychowicz, Alex
    Kozerke, Sebastian
    Hope, Mike
    Wieben, Oliver
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (05) : 1015 - 1036
  • [4] Third trimester fetal 4D flow MRI with motion correction
    Tompkins, Reagan M.
    Fujiwara, Takashi
    Schrauben, Eric M.
    Browne, Lorna P.
    van Schuppen, Joost
    Clur, Sally-Ann
    Friesen, Richard M.
    Englund, Erin K.
    Barker, Alex J.
    van Ooij, Pim
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (05) : 1969 - 1983
  • [5] CHILDREN - Fetal 4D Flow MRI with Doppler Ultrasound Gating
    不详
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2023, : 771 - 771
  • [6] Intracardiac Flow at 4D CT: Comparison with 4D Flow MRI
    Lantz, Jonas
    Gupta, Vikas
    Henriksson, Lilian
    Karlsson, Matts
    Persson, Anders
    Carlhall, Carl-Johan
    Ebbers, Tino
    RADIOLOGY, 2018, 289 (01) : 51 - 58
  • [7] 4D flow imaging with MRI
    Stankovic, Zoran
    Allen, Bradley D.
    Garcia, Julio
    Jarvis, Kelly B.
    Markl, Michael
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2014, 4 (02) : 173 - 192
  • [8] 4D Flow Meets CT: Can It Compete with 4D Flow MRI?
    Schoepf, U. Joseph
    Varga-Szemes, Akos
    RADIOLOGY, 2018, 289 (01) : 59 - 60
  • [9] Reliability of 4D Flow MRI for Investigation of Fetal Cardiovascular Hemodynamics in the Third Trimester
    Englund, Erin K.
    Fujiwara, Takashi
    Smith, Sarah A.
    Meyers, Mariana L.
    Friesen, Richard M.
    Browne, Lorna P.
    Barker, Alex J.
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2024, 6 (06):
  • [10] Spiral readouts for 4D flow MRI
    Andreas Sigfridsson
    Sven Petersson
    Carl Johan Carlhall
    Tino Ebbers
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)