brainstem; dose-volume relationship; dose tolerance; stereotactic radiosurgery; complication; trigeminal neuralgia; GAMMA-KNIFE SURGERY; TRIGEMINAL NEURALGIA RADIOSURGERY; TISSUE COMPLICATION PROBABILITY; LINEAR-ACCELERATOR RADIOSURGERY; STEREOTACTIC RADIOSURGERY; RADIATION-THERAPY; SPINAL-CORD; HYPOFRACTIONATION; MODEL;
D O I
10.3171/2012.7.GKS12962
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Dose-volume data concerning the brainstem in stereotactic radiosurgery (SRS) for trigeminal neuralgia (TN) were analyzed in relation to associated complications. The authors present their set of data and compare it with currently cited information on brainstem dose tolerance associated with conventional fractionated radiation therapy and hypofractionated radiation treatment of other diseases. Methods. Stereotactic radiosurgery for TN delivers a much higher radiation dose to the brainstem in a single fraction than doses delivered by any other procedures. A literature survey of articles on radiosurgery for TN revealed no incidences of severe toxicity, unlike other high-dose procedures involving the brainstem. Published data on brainstem dose tolerance were investigated and compared with dose-volume data in TN radiosurgery. The authors also performed a biological modeling study of dose-volume data involving the brainstem in cases of TN treated with the Gamma Knife, CyberKnife, and linear accelerator based systems. Results. The brainstem may receive a maximum dose as high as 45 Gy during radiosurgery for TN. The major complication after TN radiosurgery is mild to moderate facial numbness, and few other severe toxic responses to radiation are observed. The biologically effective dose of 45 Gy in a single fraction is much higher than any brainstem dose tolerance currently cited in conventional fractionation or in single or hypofractionated radiation treatments. However, in TN radiosurgery, the dose falloff is so steep and the delivery so accurate that brainstem volumes of 0.1-0.5 cm(3) or larger receive lower planned and delivered doses than those in other radiation-related procedures. Current models are suggestive, but an extensive analysis of detailed dose-volume clinical data is needed. Conclusions. Patients whose TN is treated with radiosurgery are a valuable population in which to demonstrate the dose-volume effects of an extreme hypofractionated radiation treatment on the brainstem. The result of TN radiosurgery suggests that a very small volume of the brainstem can tolerate a drastically high dose without suffering a severe clinical injury. The authors believe that the steep dose gradient in TN radiosurgery plays a key role in the low toxicity experienced by the brainstem. (http ://thejns.org/doi/abs/10.3171/2012.7.GKS12962)
引用
收藏
页码:189 / 196
页数:8
相关论文
共 50 条
  • [31] DOSE-VOLUME EFFECTS IN THE SPINAL-CORD
    NIEMIERKO, A
    GOITEIN, M
    RADIOTHERAPY AND ONCOLOGY, 1994, 31 (03) : 265 - 267
  • [32] RADIATION DOSE-VOLUME EFFECTS AND THE PENILE BULB
    Roach, Mack, III
    Nam, Jiho
    Gagliardi, Giovanna
    El Naqa, Issam
    Deasy, Joseph O.
    Marks, Lawrence B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (03): : S130 - S134
  • [33] RADIATION DOSE-VOLUME EFFECTS OF THE URINARY BLADDER
    Viswanathan, Akila N.
    Yorke, Ellen D.
    Marks, Lawrence B.
    Eifel, Patricia J.
    Shipley, William U.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (03): : S116 - S122
  • [34] Conversion of dose-volume constraints to dose limits
    Dai, JR
    Zhu, YP
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (23): : 3927 - 3941
  • [35] Dose-volume effects in rat thoracolumbar spinal cord: the effects of nonuniform dose distribution
    Philippens, Marielle E. P.
    Pop, Lucas A. M.
    Visser, Andries G.
    van der Kogel, Albert J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01): : 204 - 213
  • [36] An improved technique for comparing Gamma Knife dose-volume distributions in stereotactic radiosurgery
    Tozer-Loft, SM
    Walton, L
    Forster, DMC
    Kemeny, AA
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (08): : 1905 - 1919
  • [37] QA of Dose-Volume Histogram
    Cheng, C.
    Das, I.
    Srivastava, S.
    Gao, Z.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [38] Lateral Dose-volume Effects in Single-fraction Radiosurgery of the Cervical Spinal Cord: A Swine Model
    Medin, P. M.
    Foster, R. D.
    van der Kogel, A.
    Sayre, J.
    Solberg, T. D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S719 - S720
  • [39] The state of our biological understanding of dose-volume effects
    Trott, KR
    PROGRESS IN RADIO-ONCOLOGY VI, 1998, : 601 - 608
  • [40] RADIATION DOSE-VOLUME EFFECTS OF OPTIC NERVES AND CHIASM
    Mayo, Charles
    Martel, Mary K.
    Marks, Lawrence B.
    Flickinger, John
    Nam, Jiho
    Kirkpatrick, John
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (03): : S28 - S35