Dose-volume effects on brainstem dose tolerance in radiosurgery

被引:27
|
作者
Xue, Jinyu [1 ]
Goldman, H. Warren [2 ]
Grimm, Jimm [3 ]
LaCouture, Tamara [1 ]
Chen, Yan [1 ]
Hughes, Lesley [1 ]
Yorke, Ellen [4 ]
机构
[1] Cooper Univ Hosp, Dept Radiat Oncol, Camden, NJ 08103 USA
[2] Cooper Univ Hosp, Dept Neurol Surg, Camden, NJ 08103 USA
[3] Holy Redeemer Hosp, Meadowbrook, PA USA
[4] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
关键词
brainstem; dose-volume relationship; dose tolerance; stereotactic radiosurgery; complication; trigeminal neuralgia; GAMMA-KNIFE SURGERY; TRIGEMINAL NEURALGIA RADIOSURGERY; TISSUE COMPLICATION PROBABILITY; LINEAR-ACCELERATOR RADIOSURGERY; STEREOTACTIC RADIOSURGERY; RADIATION-THERAPY; SPINAL-CORD; HYPOFRACTIONATION; MODEL;
D O I
10.3171/2012.7.GKS12962
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Dose-volume data concerning the brainstem in stereotactic radiosurgery (SRS) for trigeminal neuralgia (TN) were analyzed in relation to associated complications. The authors present their set of data and compare it with currently cited information on brainstem dose tolerance associated with conventional fractionated radiation therapy and hypofractionated radiation treatment of other diseases. Methods. Stereotactic radiosurgery for TN delivers a much higher radiation dose to the brainstem in a single fraction than doses delivered by any other procedures. A literature survey of articles on radiosurgery for TN revealed no incidences of severe toxicity, unlike other high-dose procedures involving the brainstem. Published data on brainstem dose tolerance were investigated and compared with dose-volume data in TN radiosurgery. The authors also performed a biological modeling study of dose-volume data involving the brainstem in cases of TN treated with the Gamma Knife, CyberKnife, and linear accelerator based systems. Results. The brainstem may receive a maximum dose as high as 45 Gy during radiosurgery for TN. The major complication after TN radiosurgery is mild to moderate facial numbness, and few other severe toxic responses to radiation are observed. The biologically effective dose of 45 Gy in a single fraction is much higher than any brainstem dose tolerance currently cited in conventional fractionation or in single or hypofractionated radiation treatments. However, in TN radiosurgery, the dose falloff is so steep and the delivery so accurate that brainstem volumes of 0.1-0.5 cm(3) or larger receive lower planned and delivered doses than those in other radiation-related procedures. Current models are suggestive, but an extensive analysis of detailed dose-volume clinical data is needed. Conclusions. Patients whose TN is treated with radiosurgery are a valuable population in which to demonstrate the dose-volume effects of an extreme hypofractionated radiation treatment on the brainstem. The result of TN radiosurgery suggests that a very small volume of the brainstem can tolerate a drastically high dose without suffering a severe clinical injury. The authors believe that the steep dose gradient in TN radiosurgery plays a key role in the low toxicity experienced by the brainstem. (http ://thejns.org/doi/abs/10.3171/2012.7.GKS12962)
引用
收藏
页码:189 / 196
页数:8
相关论文
共 50 条
  • [21] THE DOSE-VOLUME RESPONSE OF POSTERIOR FOSSA AND BRAINSTEM WITH RESPECT TO ACUTE FATIGUE
    Gulliford, S.
    Miah, A.
    Brennan, S.
    Partridge, M.
    Harrington, K.
    Nutting, C.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S428 - S428
  • [22] DOSE-VOLUME HISTOGRAMS
    DRZYMALA, RE
    MOHAN, R
    BREWSTER, L
    CHU, J
    GOITEIN, M
    HARMS, W
    URIE, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01): : 71 - 78
  • [23] STEREOTAXIC RADIOSURGERY - DOSE-VOLUME ANALYSIS OF LINEAR-ACCELERATOR TECHNIQUES
    SERAGO, CF
    HOUDEK, PV
    BAUERKIRPES, B
    LEWIN, AA
    ABITBOL, AA
    GONZALEZARIAS, S
    MARCIALVEGA, VA
    SCHWADE, JG
    MEDICAL PHYSICS, 1992, 19 (01) : 181 - 185
  • [24] Dose-volume analysis in obliteration of AVM treated by Gamma Knife radiosurgery
    Terahara, A
    Tago, M
    Shin, M
    Nakagawa, K
    Aoki, Y
    Ohtomo, K
    RADIOLOGY, 2001, 221 : 428 - 428
  • [25] Radiation Dose-Volume Effects for Liver SBRT
    Miften, Moyed
    Vinogradskiy, Yevgeniy
    Moiseenko, Vitali
    Grimm, Jimm
    Yorke, Ellen
    Jackson, Andrewy
    Tome, Wolfgang A.
    Ten Haken, Randall K.
    Ohri, Nitin
    Romero, Alejandra Mendez
    Goodman, Karyn A.
    Marks, Lawrence B.
    Kavanagh, Brian
    Dawson, Laura A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 110 (01): : 196 - 205
  • [26] RADIATION DOSE-VOLUME EFFECTS IN THE LARYNX AND PHARYNX
    Rancati, Tiziana
    Schwarz, Marco
    Allen, Aaron M.
    Feng, Felix
    Popovtzer, Aron
    Mittal, Bharat
    Eisbruch, Avraham
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (03): : S64 - S69
  • [27] DOSE-VOLUME EFFECTS IN THE SPINAL-CORD
    VANDERKOGEL, AJ
    RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 105 - 109
  • [28] Radiation Dose-Volume Effects and the Penile Bulb
    Roach, M., III
    Nam, J.
    Gagliardi, G.
    El Naqa, I.
    Deasy, J. O.
    Marks, L. B.
    JOURNAL OF UROLOGY, 2010, 184 (06): : 2405 - 2405
  • [29] RADIATION DOSE-VOLUME EFFECTS IN THE SPINAL CORD
    Kirkpatrick, John P.
    van der Kogel, Albert J.
    Schultheiss, Timothy E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (03): : S42 - S49
  • [30] Radiation dose-volume effects for liver SBRT
    Miften, M.
    Vinogradskiy, Y.
    Moiseenko, V.
    Grimm, J.
    Yorke, E.
    Jackson, A.
    Tome, W. A.
    Ten Haken, R.
    Ohri, N.
    Romero, A. M.
    Goodman, K. A.
    Marks, L. B.
    Kavanagh, B.
    Dawson, L. A.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S45 - S45