Amperometric ATP biosensor based on polymer entrapped enzymes

被引:93
|
作者
Kueng, A [1 ]
Kranz, C [1 ]
Mizaikoff, B [1 ]
机构
[1] Georgia Inst Technol, Sch Chem & Biochem, Atlanta, GA 30332 USA
来源
BIOSENSORS & BIOELECTRONICS | 2004年 / 19卷 / 10期
基金
美国国家科学基金会; 奥地利科学基金会;
关键词
ATP biosensor; hexokinase; glucose oxidase; microelectrode; amperometric sensor; polymerization;
D O I
10.1016/j.bios.2003.11.023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A dual enzyme electrode for the detection of adenosine-5'-triphosphate (ATP) at physiologically relevant pH levels was developed by co-immobilization of the enzymes glucose oxidase (GOD) and hexokinase (HEX) using pH-shift induced deposition of enzyme containing polymer films. Application of a simple electrochemical procedure for the co-immobilization of the enzymes at electrode surfaces exhibits a major improvement of sensitivity, response time, reproducibility, and ease of fabrication of ATP bbiosensors. Competition between glucose oxidase and hexokinase for the substrate glucose involving ATP as a co-substrate allows the determination of ATP concentrations. Notable control on the immobilization process enables fabrication of micro biosensors with a diameter of 25 mum. The presented concept provides the technological basis for a new generation of fast responding, sensitive, and robust biosensors for the detection of ATP at physiological pH values with a detection limit of 10 nmol1(-1). (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:1301 / 1307
页数:7
相关论文
共 50 条
  • [31] Mathematical Modelling of Amperometric Glucose Biosensor Based on Immobilized Enzymes: New Approach of Taylors Series Method
    Narayanan, K. Lakshmi
    Kavitha, J.
    Rani, Ramu Usha
    Lyons, Michael E. G.
    Rajendran, Lakshmanan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (10):
  • [32] An amperometric biosensor for glucose based on electrodeposited redox polymer/glucose oxidase film on a gold electrode
    Fei, JJ
    Wu, YH
    Ji, XB
    Wang, J
    Hu, SS
    Gao, ZQ
    ANALYTICAL SCIENCES, 2003, 19 (09) : 1259 - 1263
  • [33] Sol-gel-based amperometric glucose biosensor incorporating an osmium redox polymer as mediator
    Park, TM
    Iwuoha, EI
    Smyth, MR
    MacCraith, BD
    ANALYTICAL COMMUNICATIONS, 1996, 33 (08): : 271 - 273
  • [34] An Amperometric Biosensor for Glucose Based on Electrodeposited Redox Polymer/Glucose Oxidase Film on a Gold Electrode
    Junjie Fei
    Yunhua Wu
    Xiaobo Ji
    Jing Wang
    Shengshui Hu
    Zhiqiang Gao
    Analytical Sciences, 2003, 19 : 1259 - 1263
  • [35] Amperometric biosensor for glutathione based on osmium-polyvinylpyridine gel polymer and glutathione sulfhydryl oxidase
    Mao, LQ
    Yamamoto, K
    ELECTROANALYSIS, 2000, 12 (08) : 577 - 582
  • [36] Enzyme Based Amperometric Biosensor for Adenine Determination
    Boka, Beata
    Adanyi, Nora
    Virag, Diana
    Frebort, Ivo
    Kiss, Attila
    ELECTROANALYSIS, 2013, 25 (01) : 237 - 242
  • [37] Amperometric Glucose Biosensor Based on Carbon Nanoparticles
    Wang Mei-Fang
    Zhang Wei
    Fang Bin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (01) : 125 - 128
  • [38] Amperometric tyrosinase biosensor based on polyacrylamide microgels
    Hervas Perez, J. P.
    Sanchez-Paniagua Lopez, M.
    Lopez-Cabarcos, E.
    Lopez-Ruiz, B.
    BIOSENSORS & BIOELECTRONICS, 2006, 22 (03): : 429 - 439
  • [39] An amperometric glucose biosensor based on PEDOT nanofibers
    Cetin, Merih Zeynep
    Camurlu, Pinar
    RSC ADVANCES, 2018, 8 (35): : 19724 - 19731
  • [40] Amperometric glucose biosensor based on electroconductive hydrogels
    Kotanen, Christian N.
    Tlili, Chaker
    Guiseppi-Elie, Anthony
    TALANTA, 2013, 103 : 228 - 235