Amperometric ATP biosensor based on polymer entrapped enzymes

被引:93
|
作者
Kueng, A [1 ]
Kranz, C [1 ]
Mizaikoff, B [1 ]
机构
[1] Georgia Inst Technol, Sch Chem & Biochem, Atlanta, GA 30332 USA
来源
BIOSENSORS & BIOELECTRONICS | 2004年 / 19卷 / 10期
基金
美国国家科学基金会; 奥地利科学基金会;
关键词
ATP biosensor; hexokinase; glucose oxidase; microelectrode; amperometric sensor; polymerization;
D O I
10.1016/j.bios.2003.11.023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A dual enzyme electrode for the detection of adenosine-5'-triphosphate (ATP) at physiologically relevant pH levels was developed by co-immobilization of the enzymes glucose oxidase (GOD) and hexokinase (HEX) using pH-shift induced deposition of enzyme containing polymer films. Application of a simple electrochemical procedure for the co-immobilization of the enzymes at electrode surfaces exhibits a major improvement of sensitivity, response time, reproducibility, and ease of fabrication of ATP bbiosensors. Competition between glucose oxidase and hexokinase for the substrate glucose involving ATP as a co-substrate allows the determination of ATP concentrations. Notable control on the immobilization process enables fabrication of micro biosensors with a diameter of 25 mum. The presented concept provides the technological basis for a new generation of fast responding, sensitive, and robust biosensors for the detection of ATP at physiological pH values with a detection limit of 10 nmol1(-1). (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:1301 / 1307
页数:7
相关论文
共 50 条
  • [21] An Amperometric Biosensor Based on Laccase Immobilized in Polymer Matrices for Determining Phenolic Compounds
    A. I. Yaropolov
    S. V. Shleev
    O. V. Morozova
    E. A. Zaitseva
    G. Marko-Varga
    J. Emneus
    L. Gorton
    Journal of Analytical Chemistry, 2005, 60 : 553 - 557
  • [22] Amperometric Phenol Biosensor Based on Horseradish Peroxidase Entrapped PVF and PPy Composite Film Coated GC Electrode
    Meral Topcu Sulak
    Elif Erhan
    Bülent Keskinler
    Applied Biochemistry and Biotechnology, 2010, 160 : 856 - 867
  • [23] Amperometric Phenol Biosensor Based on Horseradish Peroxidase Entrapped PVF and PPy Composite Film Coated GC Electrode
    Sulak, Meral Topcu
    Erhan, Elif
    Keskinler, Buelent
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2010, 160 (03) : 856 - 867
  • [24] Mediator-free amperometric glucose biosensor based on glucose oxidase entrapped in poly(vinyl alcohol) matrix
    Guascito, Maria Rachele
    Chirizzi, Daniela
    Malitesta, Cosimino
    Mazzotta, Elisabetta
    ANALYST, 2011, 136 (01) : 164 - 173
  • [25] The orientationally controlled assembly of genetically modified enzymes in an amperometric biosensor
    Gwenin, C. D.
    Kalaji, M.
    Williams, P. A.
    Jones, R. M.
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (12): : 2869 - 2875
  • [27] Amperometric phenol biosensor based on polyaniline
    Wang, Peng
    Liu, Min
    Kan, Jinqing
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (02): : 577 - 584
  • [28] A Polymer Multilayer Based Amperometric Biosensor for the Detection of Lactose in the Presence of High Concentrations of Glucose
    Lopez, Francesca
    Ma, Su
    Ludwig, Roland
    Schuhmann, Wolfgang
    Ruff, Adrian
    ELECTROANALYSIS, 2017, 29 (01) : 154 - 161
  • [29] Construction of an amperometric triglyceride biosensor using PVA membrane bound enzymes
    Pundir, C. S.
    Singh, Bharvi Sandeep
    Narang, Jagriti
    CLINICAL BIOCHEMISTRY, 2010, 43 (4-5) : 467 - 472
  • [30] A New Amperometric Biosensor for Diamine: Use of a Conducting Polymer Layer
    Al Layla, Alaa M. T.
    Turkarslan, Ozlem
    Kurbanoglu, Sevinc
    Sulaiman, Saddalah T.
    Al-Flayeh, K. A.
    Toppare, Levent
    JOURNAL OF MACROMOLECULAR SCIENCE PART A-PURE AND APPLIED CHEMISTRY, 2013, 50 (09): : 914 - 922