Sol-gel-based amperometric glucose biosensor incorporating an osmium redox polymer as mediator

被引:24
|
作者
Park, TM
Iwuoha, EI
Smyth, MR
MacCraith, BD
机构
[1] DUBLIN CITY UNIV,SCH CHEM SCI,BIOMED & ENVIRONM SCI TECHNOL CTR,DUBLIN 9,IRELAND
[2] SUNCHEON TECH JR COLL,DEPT ENVIRONM ENGN,SUNCHON 540744,SOUTH KOREA
[3] DUBLIN CITY UNIV,SCH PHYS SCI,BIOMED & ENVIRONM SCI TECHNOL CTR,DUBLIN 9,IRELAND
来源
ANALYTICAL COMMUNICATIONS | 1996年 / 33卷 / 08期
关键词
D O I
10.1039/ac9963300271
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel amperometric biosensor for the determination of glucose was constructed by first immobilizing glucose oxidase and an osmium redox polymer, [Os(bpy)(2)(PVP)(10)Cl]Cl, on the surface of a glassy-carbon electrode, followed by coating with a sol-gel film derived from methyltriethoxysilane. The redox potential of this electrode was found to be +247 mV versus Ag/AgCl, and glucose could therefore be determined amperometrically at +400 mV versus Ag/AgCl. The concentration range of linear response, slope of linear response and LOD were 2.0-31 mmol l(-1), 44.5 nA mmol(-1) I and 0.5 mmol l(-1), respectively, Although L-ascorbate was electrooxidizable at this potential, uric acid and paracetamol were both found not to interfere.
引用
收藏
页码:271 / 273
页数:3
相关论文
共 50 条
  • [1] Sol-gel based amperometric biosensor incorporating an osmium redox polymer as mediator for detection of L-lactate
    Park, TM
    Iwuoha, EI
    Smyth, MR
    Freaney, R
    McShane, AJ
    TALANTA, 1997, 44 (06) : 973 - 978
  • [2] Amperometric determination of hydrogen peroxide by utilizing a sol-gel-derived biosensor incorporating an osmium redox polymer as mediator
    Park, TM
    ANALYTICAL LETTERS, 1999, 32 (02) : 287 - 298
  • [3] Sol-gel-based biosensor for use in stroke treatment
    Grant, SA
    Glass, RS
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (10) : 1207 - 1211
  • [4] Reagentless amperometric glucose dehydrogenase biosensor based on electrocatalytic oxidation of NADH by osmium phenanthrolinedione mediator
    Hedenmo, M
    Narvaez, A
    Dominguez, E
    Katakis, I
    ANALYST, 1996, 121 (12) : 1891 - 1895
  • [5] Evaluation of an amperometric glucose biosensor based on a ruthenium complex mediator of low redox potential
    Yamamoto, K
    Zeng, HS
    Shen, Y
    Ahmed, MM
    Kato, T
    TALANTA, 2005, 66 (05) : 1175 - 1180
  • [6] Amperometric biosensor for glutathione based on osmium-polyvinylpyridine gel polymer and glutathione sulfhydryl oxidase
    Mao, LQ
    Yamamoto, K
    ELECTROANALYSIS, 2000, 12 (08) : 577 - 582
  • [7] An amperometric biosensor for glucose based on electrodeposited redox polymer/glucose oxidase film on a gold electrode
    Fei, JJ
    Wu, YH
    Ji, XB
    Wang, J
    Hu, SS
    Gao, ZQ
    ANALYTICAL SCIENCES, 2003, 19 (09) : 1259 - 1263
  • [8] An Amperometric Biosensor for Glucose Based on Electrodeposited Redox Polymer/Glucose Oxidase Film on a Gold Electrode
    Junjie Fei
    Yunhua Wu
    Xiaobo Ji
    Jing Wang
    Shengshui Hu
    Zhiqiang Gao
    Analytical Sciences, 2003, 19 : 1259 - 1263
  • [9] A metal dispersed sol-gel biocomposite amperometric glucose biosensor
    Shankaran, DR
    Uehara, N
    Kato, T
    BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6): : 721 - 728
  • [10] Enzyme biosensor based on an electropolymerized osmium redox polymer
    Tsujimoto, M
    Maruyama, K
    Mishima, Y
    Motonaka, J
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2003, 17 (8-9): : 1517 - 1522