Sol-gel-based amperometric glucose biosensor incorporating an osmium redox polymer as mediator

被引:24
|
作者
Park, TM
Iwuoha, EI
Smyth, MR
MacCraith, BD
机构
[1] DUBLIN CITY UNIV,SCH CHEM SCI,BIOMED & ENVIRONM SCI TECHNOL CTR,DUBLIN 9,IRELAND
[2] SUNCHEON TECH JR COLL,DEPT ENVIRONM ENGN,SUNCHON 540744,SOUTH KOREA
[3] DUBLIN CITY UNIV,SCH PHYS SCI,BIOMED & ENVIRONM SCI TECHNOL CTR,DUBLIN 9,IRELAND
来源
ANALYTICAL COMMUNICATIONS | 1996年 / 33卷 / 08期
关键词
D O I
10.1039/ac9963300271
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel amperometric biosensor for the determination of glucose was constructed by first immobilizing glucose oxidase and an osmium redox polymer, [Os(bpy)(2)(PVP)(10)Cl]Cl, on the surface of a glassy-carbon electrode, followed by coating with a sol-gel film derived from methyltriethoxysilane. The redox potential of this electrode was found to be +247 mV versus Ag/AgCl, and glucose could therefore be determined amperometrically at +400 mV versus Ag/AgCl. The concentration range of linear response, slope of linear response and LOD were 2.0-31 mmol l(-1), 44.5 nA mmol(-1) I and 0.5 mmol l(-1), respectively, Although L-ascorbate was electrooxidizable at this potential, uric acid and paracetamol were both found not to interfere.
引用
收藏
页码:271 / 273
页数:3
相关论文
共 50 条
  • [31] AMPEROMETRIC BIOSENSOR FOR GLUCOSE BASED ON NAFION LOADED WITH REDOX COUPLES AND GLUCOSE-OXIDASE
    BELANGER, D
    VAILLANCOURT, M
    FORTIER, G
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 1 - ANYL
  • [32] Al2O3 sol-gel derived amperometric biosensor for glucose
    Liu, ZJ
    Liu, BH
    Zhang, M
    Kong, JL
    Deng, JQ
    ANALYTICA CHIMICA ACTA, 1999, 392 (2-3) : 135 - 141
  • [33] GLUCOSE BIOSENSOR BASED ON A SOL-GEL-DERIVED PLATFORM
    NARANG, U
    PRASAD, PN
    BRIGHT, FV
    RAMANATHAN, K
    KUMAR, ND
    MALHOTRA, BD
    KAMALASANAN, MN
    CHANDRA, S
    ANALYTICAL CHEMISTRY, 1994, 66 (19) : 3139 - 3144
  • [34] Sol-gel-based carbon/silicon carbide
    Liedtke, V.
    Olivares, I. Huertas
    Langer, M.
    Haruvy, Y. F.
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2007, 27 (2-3) : 1267 - 1272
  • [35] Water stability of a cheap sol-gel-based adhesive
    Janne Puputti
    Mika Lindén
    Adsorption, 2009, 15 : 329 - 335
  • [36] A new amperometric glucose biosensor with naphthol green B as mediator
    Zhao, Q
    Yuan, R
    Mo, CL
    Chai, YQ
    Zhong, X
    CHINESE CHEMICAL LETTERS, 2004, 15 (02) : 208 - 211
  • [37] Computational Modeling of Mediator Oxidation by Oxygen in an Amperometric Glucose Biosensor
    Simelevicius, Dainius
    Petrauskas, Karolis
    Baronas, Romas
    Razumiene, Julija
    SENSORS, 2014, 14 (02): : 2578 - 2594
  • [39] Condensation a-Cyclodextrin Polymer Membrane with Covalently Immobilized Glucose Oxidase and Molecularly Included Mediator for Amperometric Glucose Biosensor
    Kutner, W.
    Wu, H.
    Kadish, K. M.
    Journal of Microcolumn Separation, 768
  • [40] Amperometric biosensor for inert organic solvents based on a sol-gel hybrid material
    Wang, BQ
    Zhang, JZ
    Cheng, GJ
    Dong, SJ
    CHEMICAL COMMUNICATIONS, 2000, (21) : 2123 - 2124