Sol-gel-based amperometric glucose biosensor incorporating an osmium redox polymer as mediator

被引:24
|
作者
Park, TM
Iwuoha, EI
Smyth, MR
MacCraith, BD
机构
[1] DUBLIN CITY UNIV,SCH CHEM SCI,BIOMED & ENVIRONM SCI TECHNOL CTR,DUBLIN 9,IRELAND
[2] SUNCHEON TECH JR COLL,DEPT ENVIRONM ENGN,SUNCHON 540744,SOUTH KOREA
[3] DUBLIN CITY UNIV,SCH PHYS SCI,BIOMED & ENVIRONM SCI TECHNOL CTR,DUBLIN 9,IRELAND
来源
ANALYTICAL COMMUNICATIONS | 1996年 / 33卷 / 08期
关键词
D O I
10.1039/ac9963300271
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel amperometric biosensor for the determination of glucose was constructed by first immobilizing glucose oxidase and an osmium redox polymer, [Os(bpy)(2)(PVP)(10)Cl]Cl, on the surface of a glassy-carbon electrode, followed by coating with a sol-gel film derived from methyltriethoxysilane. The redox potential of this electrode was found to be +247 mV versus Ag/AgCl, and glucose could therefore be determined amperometrically at +400 mV versus Ag/AgCl. The concentration range of linear response, slope of linear response and LOD were 2.0-31 mmol l(-1), 44.5 nA mmol(-1) I and 0.5 mmol l(-1), respectively, Although L-ascorbate was electrooxidizable at this potential, uric acid and paracetamol were both found not to interfere.
引用
收藏
页码:271 / 273
页数:3
相关论文
共 50 条
  • [21] Development of an amperometric biosensor based on a redox-mediator-doped polypyrrole film
    Rajesh
    Pandey, SS
    Takashima, W
    Kaneto, K
    JOURNAL OF APPLIED POLYMER SCIENCE, 2004, 93 (02) : 927 - 933
  • [22] Sol-gel based thermal biosensor for glucose
    Ramanathan, K
    Jönsson, BR
    Danielsson, B
    ANALYTICA CHIMICA ACTA, 2001, 427 (01) : 1 - 10
  • [23] Sol-gel-derived prussian blue-silicate amperometric glucose biosensor
    Subramanian Bharathi
    Ovadia Lev
    Applied Biochemistry and Biotechnology, 2000, 89 : 209 - 216
  • [24] Sol-gel-derived prussian blue-silicate amperometric glucose biosensor
    Bharathi, S
    Lev, O
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2000, 89 (2-3) : 209 - 216
  • [25] IMMOBILIZATION OF GLUCOSE OXIDASE IN SILICA SOL-GEL FILM FOR APPLICATION TO BIOSENSOR AND AMPEROMETRIC DETERMINATION OF GLUCOSE
    Demirkiran, Nizamettin
    Ekinci, Ergun
    Asilturk, Meltem
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2012, 57 (04) : 1336 - 1339
  • [26] EVALUATION OF AMPEROMETRIC GLUCOSE BIOSENSORS BASED ON COIMMOBILIZATION OF GLUCOSE-OXIDASE WITH AN OSMIUM REDOX POLYMER IN ELECTROCHEMICALLY GENERATED POLYPHENOL FILMS
    PRAVDA, M
    JUNGAR, CM
    IWUOHA, EI
    SMYTH, MR
    VYTRAS, K
    IVASKA, A
    ANALYTICA CHIMICA ACTA, 1995, 304 (02) : 127 - 138
  • [27] A Simple and Fast Method for Detecting Glucose in Wines Using a Redox Polymer-Based Amperometric Biosensor
    Muresan, Laura
    Gaspar, Szilveszter
    Turdean, Grazielia
    Popescu, Ionel Catalin
    REVISTA DE CHIMIE, 2010, 61 (02): : 126 - 129
  • [28] Sulfite biosensor based on osmium redox polymer wired sulfite oxidase
    Spricigo, Roberto
    Richter, Claudia
    Leimkuehler, Silke
    Gorton, Lo
    Scheller, Frieder W.
    Wollenberger, Ulla
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2010, 354 (1-3) : 314 - 319
  • [29] Sol-gel-derived amperometric glucose biosensor based on covalent attachment of toluidine blue O to carrier
    Qian, JM
    Li, XX
    Huang, HY
    POLYMERS FOR ADVANCED TECHNOLOGIES, 2003, 14 (3-5) : 207 - 211
  • [30] Amperometric glucose biosensor based on sol-gel-derived zirconia/Nafion composite film as encapsulation matrix
    Kim, HJ
    Yoon, SH
    Choi, HN
    Lyu, YK
    Lee, WY
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2006, 27 (01): : 65 - 70