Long-term kinematic analysis of cervical spine after single-level implantation of Bryan cervical disc prosthesis

被引:39
|
作者
Ryu, Won Hyung A. [1 ]
Kowalczyk, Izabela [2 ,3 ]
Duggal, Neil [1 ,2 ,3 ,4 ]
机构
[1] Univ Western Ontario, Schulich Sch Med & Dent, London, ON, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] Univ Western Ontario, Ctr Funct & Metab Mapping, Robarts Res Inst, London, ON, Canada
[4] Univ Western Ontario, Univ Hosp, London Hlth Sci Ctr, Dept Clin Neurol Sci,Div Neurosurg, London, ON N6A 5A5, Canada
来源
SPINE JOURNAL | 2013年 / 13卷 / 06期
关键词
Cervical arthroplasty; Kinematics; Total disc replacement; Bryan disc; Cervical disc replacement; INTERMEDIATE FOLLOW-UP; CLINICAL-TRIAL; SEGMENTAL MALALIGNMENT; INTERVERTEBRAL MOTION; ANTERIOR DISKECTOMY; ARTHROPLASTY; FUSION; DISEASE; REPLACEMENT; MULTICENTER;
D O I
10.1016/j.spinee.2013.02.046
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Cervical arthroplasty theoretically reduces the risk of adjacent level disc degeneration and segmental instability that may be seen after a cervical fusion. An essential argument in confirming the utility of cervical arthroplasty is long-term confirmation that cervical disc replacements can maintain physiological kinematics at the index and adjacent levels. PURPOSE: The purpose of this in vivo prospective study was to characterize the long-term segmental kinematic outcomes after cervical arthroplasty. STUDY DESIGN/SETTING: Prospective cohort study. PATIENT SAMPLE: Twenty patients with a 5-year clinical follow-up who underwent anterior cervical discectomy with insertion of the Bryan cervical disc. OUTCOME MEASURES: Physiological measures (kinematic analysis of lateral neutral, flexion, and extension radiographic imaging). METHODS: Twenty consecutive patients with degenerative disc disease were followed with regular radiographic imaging after implantation of the Bryan cervical disc prosthesis. Lateral neutral, flexion, and extension radiographs (n=240) were analyzed using Quantitative Motion Analysis software (Medical Metrics, Inc., Houston, TX, USA) to measure the biomechanical profile at the index level and adjacent levels up to 5 years after surgery. Parameters collected included range of motion (ROM), functional spinal unit (FSU) angle, anterior and posterior disc heights, sagittal translation, and center of rotation (COR). RESULTS: Biomechanics of the implanted artificial cervical disc was maintained up to 5 years with no significant changes in ROM, FSU angle, disc height, sagittal translation, and COR values when compared with early postoperative performance. Artificial discs were able to adequately restore and maintain preoperative kinematics. Early differences seen in disc height and FSU angle did not change during the duration of follow-up. No significant kyphotic changes or decrease in ROM were seen at the adjacent spinal levels. CONCLUSIONS: The Bryan cervical disc prosthesis provides for a durable solution for functional spinal motion at the operated level and maintained the preoperative kinematics at adjacent levels at the 5-year follow-up. Crown Copyright (C) 2013 Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:628 / 634
页数:7
相关论文
共 50 条
  • [1] Long-term kinematic analysis of cervical spine after single-level implantation of Bryan cervical disc prosthesis: a review
    Resnick, Daniel K.
    SPINE JOURNAL, 2013, 13 (06): : 635 - 636
  • [2] Longitudinal Prospective Long-term Radiographic Follow-up After Treatment of Single-Level Cervical Disk Disease With the Bryan Cervical Disc
    Walraevens, Joris
    Demaerel, Philippe
    Suetens, Paul
    Van Calenbergh, Frank
    van Loon, Johan
    Sloten, Jozef Vander
    Goffin, Jan
    NEUROSURGERY, 2010, 67 (03) : 679 - 687
  • [3] Intermediate follow-up after treatment of degenerative disc disease with the Bryan Cervical Disc Prosthesis: Single-level and bi-level
    Goffin, J
    Van Calenbergh, F
    van Loon, J
    Casey, A
    Kehr, P
    Liebig, K
    Lind, B
    Logroscino, C
    Sgrambiglia, R
    Pointillart, V
    SPINE, 2003, 28 (24) : 2673 - 2678
  • [4] Mid-long-term follow-up of operated level kinematics after single-level artificial cervical disc replacement with Bryan disc
    Li, Chuanhong
    Yu, Xing
    Xiong, Yang
    Yang, Yongdong
    Wang, Fengxian
    Zhao, He
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [5] Mid-long-term follow-up of operated level kinematics after single-level artificial cervical disc replacement with Bryan disc
    Chuanhong Li
    Xing Yu
    Yang Xiong
    Yongdong Yang
    Fengxian Wang
    He Zhao
    Journal of Orthopaedic Surgery and Research, 17
  • [6] Kinematic analysis of the cervical spine following implantation of an artificial cervical disc
    Pickett, GE
    Rouleau, JP
    Duggal, N
    SPINE, 2005, 30 (17) : 1949 - 1954
  • [7] Dynamic simulation of cervical spine following single-level cervical disc replacement
    de Jongh, Cornel U.
    Basson, Anton H.
    Scheffer, Cornie
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4289 - 4292
  • [8] Wear analysis of the Bryan Cervical Disc prosthesis
    Anderson, PA
    Rouleau, JP
    Bryan, VE
    Carlson, CS
    SPINE, 2003, 28 (20) : S186 - S194
  • [9] A radiostereometric analysis of the Bryan® cervical disc prosthesis
    Lind, Bengt
    Zoega, Bjorn
    Anderson, Paul A.
    SPINE, 2007, 32 (08) : 885 - 890
  • [10] Extent of Disc Degeneration after Single-Level Cervical Anterior Microforaminotomy Analyzed with Long-Term Radiological Data
    Han, Chul
    Kim, Myung-Hyun
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2014, 56 (03) : 200 - 205