Long-term kinematic analysis of cervical spine after single-level implantation of Bryan cervical disc prosthesis

被引:39
|
作者
Ryu, Won Hyung A. [1 ]
Kowalczyk, Izabela [2 ,3 ]
Duggal, Neil [1 ,2 ,3 ,4 ]
机构
[1] Univ Western Ontario, Schulich Sch Med & Dent, London, ON, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] Univ Western Ontario, Ctr Funct & Metab Mapping, Robarts Res Inst, London, ON, Canada
[4] Univ Western Ontario, Univ Hosp, London Hlth Sci Ctr, Dept Clin Neurol Sci,Div Neurosurg, London, ON N6A 5A5, Canada
来源
SPINE JOURNAL | 2013年 / 13卷 / 06期
关键词
Cervical arthroplasty; Kinematics; Total disc replacement; Bryan disc; Cervical disc replacement; INTERMEDIATE FOLLOW-UP; CLINICAL-TRIAL; SEGMENTAL MALALIGNMENT; INTERVERTEBRAL MOTION; ANTERIOR DISKECTOMY; ARTHROPLASTY; FUSION; DISEASE; REPLACEMENT; MULTICENTER;
D O I
10.1016/j.spinee.2013.02.046
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Cervical arthroplasty theoretically reduces the risk of adjacent level disc degeneration and segmental instability that may be seen after a cervical fusion. An essential argument in confirming the utility of cervical arthroplasty is long-term confirmation that cervical disc replacements can maintain physiological kinematics at the index and adjacent levels. PURPOSE: The purpose of this in vivo prospective study was to characterize the long-term segmental kinematic outcomes after cervical arthroplasty. STUDY DESIGN/SETTING: Prospective cohort study. PATIENT SAMPLE: Twenty patients with a 5-year clinical follow-up who underwent anterior cervical discectomy with insertion of the Bryan cervical disc. OUTCOME MEASURES: Physiological measures (kinematic analysis of lateral neutral, flexion, and extension radiographic imaging). METHODS: Twenty consecutive patients with degenerative disc disease were followed with regular radiographic imaging after implantation of the Bryan cervical disc prosthesis. Lateral neutral, flexion, and extension radiographs (n=240) were analyzed using Quantitative Motion Analysis software (Medical Metrics, Inc., Houston, TX, USA) to measure the biomechanical profile at the index level and adjacent levels up to 5 years after surgery. Parameters collected included range of motion (ROM), functional spinal unit (FSU) angle, anterior and posterior disc heights, sagittal translation, and center of rotation (COR). RESULTS: Biomechanics of the implanted artificial cervical disc was maintained up to 5 years with no significant changes in ROM, FSU angle, disc height, sagittal translation, and COR values when compared with early postoperative performance. Artificial discs were able to adequately restore and maintain preoperative kinematics. Early differences seen in disc height and FSU angle did not change during the duration of follow-up. No significant kyphotic changes or decrease in ROM were seen at the adjacent spinal levels. CONCLUSIONS: The Bryan cervical disc prosthesis provides for a durable solution for functional spinal motion at the operated level and maintained the preoperative kinematics at adjacent levels at the 5-year follow-up. Crown Copyright (C) 2013 Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:628 / 634
页数:7
相关论文
共 50 条
  • [41] Multi-level cervical disc arthroplasty (CDA) versus single-level CDA for the treatment of cervical disc diseases: a meta-analysis
    Hua Zhao
    Lei Cheng
    Yong Hou
    Yi Liu
    Ben Liu
    Jyoti Joshi Mundra
    Lin Nie
    European Spine Journal, 2015, 24 : 101 - 112
  • [42] Implantation of an empty carbon fiber composite frame cage after single-level anterior cervical discectomy in the treatment of cervical disc herniation: preliminary results
    Payer, M
    May, D
    Reverdin, A
    Tessitore, E
    JOURNAL OF NEUROSURGERY, 2003, 98 (02) : 143 - 148
  • [43] A prospective randomized study of anterior single-level cervical disc operations with long-term follow-up: Surgical fusion is unnecessary
    Savolainen, S
    Rinne, J
    Hernesniemi, J
    NEUROSURGERY, 1998, 43 (01) : 51 - 55
  • [45] Postoperative Segmental Malalignment After Surgery With the Bryan Cervical Disc Prosthesis Is it Related to the Mechanics and Design of the Prosthesis?
    Walraevens, Joris R. R.
    Liu, Baoge
    Vander Sloten, Jozef
    Demaerel, Philippe
    Goffin, Jan
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2010, 23 (06): : 372 - 376
  • [46] Multidirectional Flexibility of the Spine Following Posterior Decompressive Surgery After Single-Level Cervical Disc Arthroplasty An In Vitro Biomechanical Investigation
    Kikkawa, Jun
    Cunningham, Bryan W.
    Shirado, Osamu
    Hu, Nianbin
    McAfee, Paul C.
    Oda, Hiromi
    SPINE, 2010, 35 (25) : E1465 - E1471
  • [47] Interim follow-up after treatment of degenerative disc disease with the Bryan Cervical Disc Prosthesis
    Lafuente, J
    Casey, A
    Goffin, J
    Kher, P
    Liebig, M
    Lind, B
    Logroscino, C
    Pointillart, V
    Singh, A
    NEUROSURGERY, 2002, 51 (02) : 583 - 584
  • [48] Resorbable anterior cervical plates for single-level degenerative disc disease
    Bindal, Rajesh K.
    Ghosh, Subrata
    Foldi, Reatrix
    NEUROSURGERY, 2007, 61 (05) : 305 - 309
  • [49] Adjacent-Level Cervical Ossification After Bryan Cervical Disc Arthroplasty Compared with Anterior Cervical Discectomy and Fusion
    Garrido, Ben J.
    Wilhite, Jon
    Nakano, Masato
    Crawford, Charles
    Baldus, Christine
    Riew, K. Daniel
    Sasso, Rick C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (13): : 1185 - 1189
  • [50] Clinical and radiologic comparison of dynamic cervical implant arthroplasty and cervical total disc replacement for single-level cervical degenerative disc disease
    Liu Shichang
    Song Yueming
    Liu Limin
    Wang Lei
    Zhou Zhongjie
    Zhou Chunguang
    Yang Xi
    JOURNAL OF CLINICAL NEUROSCIENCE, 2016, 27 : 102 - 109