Long-term kinematic analysis of cervical spine after single-level implantation of Bryan cervical disc prosthesis

被引:39
|
作者
Ryu, Won Hyung A. [1 ]
Kowalczyk, Izabela [2 ,3 ]
Duggal, Neil [1 ,2 ,3 ,4 ]
机构
[1] Univ Western Ontario, Schulich Sch Med & Dent, London, ON, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] Univ Western Ontario, Ctr Funct & Metab Mapping, Robarts Res Inst, London, ON, Canada
[4] Univ Western Ontario, Univ Hosp, London Hlth Sci Ctr, Dept Clin Neurol Sci,Div Neurosurg, London, ON N6A 5A5, Canada
来源
SPINE JOURNAL | 2013年 / 13卷 / 06期
关键词
Cervical arthroplasty; Kinematics; Total disc replacement; Bryan disc; Cervical disc replacement; INTERMEDIATE FOLLOW-UP; CLINICAL-TRIAL; SEGMENTAL MALALIGNMENT; INTERVERTEBRAL MOTION; ANTERIOR DISKECTOMY; ARTHROPLASTY; FUSION; DISEASE; REPLACEMENT; MULTICENTER;
D O I
10.1016/j.spinee.2013.02.046
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Cervical arthroplasty theoretically reduces the risk of adjacent level disc degeneration and segmental instability that may be seen after a cervical fusion. An essential argument in confirming the utility of cervical arthroplasty is long-term confirmation that cervical disc replacements can maintain physiological kinematics at the index and adjacent levels. PURPOSE: The purpose of this in vivo prospective study was to characterize the long-term segmental kinematic outcomes after cervical arthroplasty. STUDY DESIGN/SETTING: Prospective cohort study. PATIENT SAMPLE: Twenty patients with a 5-year clinical follow-up who underwent anterior cervical discectomy with insertion of the Bryan cervical disc. OUTCOME MEASURES: Physiological measures (kinematic analysis of lateral neutral, flexion, and extension radiographic imaging). METHODS: Twenty consecutive patients with degenerative disc disease were followed with regular radiographic imaging after implantation of the Bryan cervical disc prosthesis. Lateral neutral, flexion, and extension radiographs (n=240) were analyzed using Quantitative Motion Analysis software (Medical Metrics, Inc., Houston, TX, USA) to measure the biomechanical profile at the index level and adjacent levels up to 5 years after surgery. Parameters collected included range of motion (ROM), functional spinal unit (FSU) angle, anterior and posterior disc heights, sagittal translation, and center of rotation (COR). RESULTS: Biomechanics of the implanted artificial cervical disc was maintained up to 5 years with no significant changes in ROM, FSU angle, disc height, sagittal translation, and COR values when compared with early postoperative performance. Artificial discs were able to adequately restore and maintain preoperative kinematics. Early differences seen in disc height and FSU angle did not change during the duration of follow-up. No significant kyphotic changes or decrease in ROM were seen at the adjacent spinal levels. CONCLUSIONS: The Bryan cervical disc prosthesis provides for a durable solution for functional spinal motion at the operated level and maintained the preoperative kinematics at adjacent levels at the 5-year follow-up. Crown Copyright (C) 2013 Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:628 / 634
页数:7
相关论文
共 50 条
  • [21] A radiostereometric analysis of the Bryan® cervical disc prosthesis -: Point of view
    Monsey, Robert D.
    SPINE, 2007, 32 (08) : 891 - 891
  • [22] Cost-effectiveness analysis: comparing single-level cervical disc replacement and single-level anterior cervical discectomy and fusion
    Qureshi, Sheeraz A.
    McAnany, Steven
    Goz, Vadim
    Koehler, Steven M.
    Hecht, Andrew C.
    JOURNAL OF NEUROSURGERY-SPINE, 2013, 19 (05) : 546 - 554
  • [23] Costs of Cervical Disc Replacement Versus Anterior Cervical Discectomy and Fusion for Treatment of Single-Level Cervical Disc Disease An Analysis of the Blue Health Intelligence Database for Acute and Long-term Costs and Complications
    Radcliff, Kris
    Zigler, Jeff
    Zigler, Jack
    SPINE, 2015, 40 (08) : 521 - 529
  • [24] Local and global subaxial cervical spine biomechanics after single-level fusion or cervical arthroplasty
    Michael A. Finn
    Darrel S. Brodke
    Michael Daubs
    Alpesh Patel
    Kent N. Bachus
    European Spine Journal, 2009, 18 : 1520 - 1527
  • [25] Local and global subaxial cervical spine biomechanics after single-level fusion or cervical arthroplasty
    Finn, Michael A.
    Brodke, Darrel S.
    Daubs, Michael
    Patel, Alpesh
    Bachus, Kent N.
    EUROPEAN SPINE JOURNAL, 2009, 18 (10) : 1520 - 1527
  • [26] Single-level cervical disc arthroplasty in the spine with reversible kyphosis: A finite element study
    Hu, Xu
    Jiang, Majiao
    Hong, Ying
    Rong, Xin
    Huang, Kangkang
    Liu, Hao
    Pu, Dan
    Wang, Beiyu
    JOR SPINE, 2022, 5 (02):
  • [27] Single-level Bryan cervical disc arthroplasty: evaluation of radiological and clinical outcomes after 18 years of follow-up
    Maurizio Genitiempo
    Andrea Perna
    Domenico Alessandro Santagada
    Maria Concetta Meluzio
    Luca Proietti
    Maria Beatrice Bocchi
    Carlo Ambrogio Logroscino
    Francesco Ciro Tamburrelli
    European Spine Journal, 2020, 29 : 2823 - 2830
  • [28] Single-level Bryan cervical disc arthroplasty: evaluation of radiological and clinical outcomes after 18 years of follow-up
    Genitiempo, Maurizio
    Perna, Andrea
    Santagada, Domenico Alessandro
    Meluzio, Maria Concetta
    Proietti, Luca
    Bocchi, Maria Beatrice
    Logroscino, Carlo Ambrogio
    Tamburrelli, Francesco Ciro
    EUROPEAN SPINE JOURNAL, 2020, 29 (11) : 2823 - 2830
  • [29] Use of a polymethylmethacrylate cervical cage in the treatment of single-level cervical disc disease
    Chen, JF
    Wu, CT
    Lee, SC
    Lee, ST
    JOURNAL OF NEUROSURGERY-SPINE, 2005, 3 (01) : 24 - 28
  • [30] Effect of Facet Tropism on Postoperative Cervical Range of Motion After Single-Level Cervical Disc Arthroplasty
    Liu, Ziyang
    Rong, Xin
    Liu, Hao
    Ding, Chen
    Hong, Ying
    Wang, Beiyu
    GLOBAL SPINE JOURNAL, 2022, 12 (08) : 1696 - 1707