Body composition assessment in adults with cystic fibrosis: comparison of dual-energy X-ray absorptiometry with skinfolds and bioelectrical impedance analysis

被引:36
|
作者
King, S
Wilson, J
Kotsimbos, T
Bailey, M
Nyulasi, I
机构
[1] Monash Univ, Alfred Hosp, Dept Med, Melbourne, Vic 3004, Australia
[2] Alfred Hosp, Dept Nutr, Melbourne, Vic, Australia
[3] Alfred Hosp, Dept Allergy Immunol & Resp Med, Melbourne, Vic, Australia
[4] Monash Univ, Dept Epidemiol & Prevent Med, Melbourne, Vic 3004, Australia
[5] Monash Univ, Med Ctr, Dept Med, Clayton, Vic 3168, Australia
基金
英国医学研究理事会;
关键词
cystic fibrosis; nutritional assessment; body composition; dual-energy X-ray absorptiometry; bioelectrical impedance analysis;
D O I
10.1016/j.nut.2005.04.005
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objective: We compared body composition measurement in adults with cystic fibrosis (CF) by using non-invasive methods (skinfold thicknesses and bioelectrical impedance analysis [BIA]) with dual-energy X-ray absorptiometry (DXA). Methods: Seventy-six adults with CF (mean age 29.9 +/- 7.9 y, mean body mass index 21.5 +/- 2.5 kg/m(2)) were studied. Body composition was measured to calculate fat-free mass (FFM) using DXA, the sum of four skinfold thicknesses, and BIA (predictive equations of Lukaski and of Segal). Results: Mean FFM values +/- standard deviation measured using DXA were 54.8 +/- 7.3 kg in men and 41.2 +/- 3.9 kg in women. Mean FFM values measured using BIA/Lukaski were 51.5 +/- 7.8 kg in men and 40.4 +/- 4.9 kg in women (P < 0.0005 for men, not significant for women for comparison with DXA). Mean FFM values measured using BIA/Segal were 54.2 +/- 7.5 kg for men and 44.1 +/- 5.9 kg for women (not significant for men, P < 0.0005 for women for comparison with DXA). Mean FFM values measured using skinfolds were significantly higher than those for FFM with DXA (57.2 +/- 7.2 kg in men, 43.3 +/- 4.3 kg in women, P < 0.0005 for comparison with DXA). The 95% limits of agreement with FFM using DXA were, for men and women, respectively, -8.3 to 1.7 kg and -6.4 to 4.8 kg for BIA/Lukaski, -4.8 to 3.6 kg and -3.1 to 8.9 kg for BIA/Segal, and -2.8 to 7.3 kg and -1.5 to 5.7 kg for skinfolds. Conclusion: This study suggests that skinfold thickness measurements and BIA will incorrectly estimate FFM in many adults with CF compared with DXA measurements of FFM. These methods have limited application in the assessment of body composition in individual adult patients with CF. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:1087 / 1094
页数:8
相关论文
共 50 条
  • [1] Comparison of skinfolds and dual-energy X-ray absorptiometry to assess change in body composition in adults with cystic fibrosis
    King, S. J.
    Wilson, J. W.
    Kotsimbos, T.
    Nyulasi, I. B.
    PEDIATRIC PULMONOLOGY, 2007, : 385 - 385
  • [2] Comparison of Body Composition by Bioelectrical Impedance Analysis and Dual-Energy X-Ray Absorptiometry in Hispanic Diabetics
    Batech, Michael
    Beeson, W. Lawrence
    Schultz, Eloy
    Salto, Lorena
    Firek, Anthony
    DeLeon, Marino
    Balcazar, Hector
    Cordero-MacIntyre, Zaida
    FASEB JOURNAL, 2010, 24
  • [3] Comparison of segmental body composition estimated by bioelectrical impedance analysis and dual-energy X-ray absorptiometry
    Wingo, Brooks C.
    Barry, Valene Garr
    Ellis, Amy C.
    Gower, Barbara A.
    CLINICAL NUTRITION ESPEN, 2018, 28 : 141 - 147
  • [4] Comparison of bioelectrical impedance analysis and dual-energy X-ray absorptiometry for the assessment of appendicular body composition in anorexic women
    Bedogni, G
    Marra, M
    Bianchi, L
    Malavolti, M
    Nicolai, E
    De Filippo, E
    Scalfi, L
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2003, 57 (09) : 1068 - 1072
  • [5] Comparison of bioelectrical impedance analysis and dual-energy X-ray absorptiometry for the assessment of appendicular body composition in anorexic women
    G Bedogni
    M Marra
    L Bianchi
    M Malavolti
    E Nicolai
    E De Filippo
    L Scalfi
    European Journal of Clinical Nutrition, 2003, 57 : 1068 - 1072
  • [6] Agreement of bioelectric impedance analysis and dual-energy X-ray absorptiometry for body composition evaluation in adults with cystic fibrosis
    Ziai, S.
    Coriati, A.
    Chabot, K.
    Mailhot, M.
    Richter, M. V.
    Rabasa-Lhoret, R.
    JOURNAL OF CYSTIC FIBROSIS, 2014, 13 (05) : 585 - 588
  • [7] Comparison of Anthropometry, Bioelectrical Impedance, and Dual-energy X-ray Absorptiometry for Body Composition in Cirrhosis
    Grover, Indu
    Singh, Namrata
    Gunjan, Deepak
    Pandey, Ravindra M.
    Sati, Hem Chandra
    Saraya, Anoop
    JOURNAL OF CLINICAL AND EXPERIMENTAL HEPATOLOGY, 2022, 12 (02) : 467 - 474
  • [8] Comparison of bioelectrical impedance analysis and dual energy X-ray absorptiometry for assessment of body composition in children
    Okasora, K
    Takaya, R
    Tokuda, M
    Fukunaga, Y
    Oguni, T
    Tanaka, H
    Konishi, K
    Tamai, H
    PEDIATRICS INTERNATIONAL, 1999, 41 (02) : 121 - 125
  • [9] BODY-COMPOSITION ANALYSIS BY DUAL-ENERGY X-RAY ABSORPTIOMETRY IN ADULTS WITH CYSTIC-FIBROSIS
    ROCHAT, T
    SLOSMAN, DO
    PICHARD, C
    BELLI, DC
    CHEST, 1994, 106 (03) : 800 - 805
  • [10] Body Composition in Heavy Smokers: Comparison of Segmental Bioelectrical Impedance Analysis and Dual-Energy X-Ray Absorptiometry
    Rom, O.
    Reznick, A. Z.
    Keidar, Z.
    Karkabi, K.
    Aizenbud, D.
    BODY METABOLISM AND EXERCISE, 2015, 840 : 1 - 11