Comparing Autorefractors for Measurement of Accommodation

被引:26
|
作者
Aldaba, Mikel [1 ]
Gomez-Lopez, Selena [1 ]
Vilaseca, Meritxell [1 ]
Pujol, Jaume [1 ]
Arjona, Montserrat [1 ]
机构
[1] Univ Politecn Cataluna, Ctr Sensors Instruments & Syst Dev CD6, Barcelona, Spain
关键词
accommodation; accommodative response; static; dynamic; WAM-5500; PowerRef-II; ECCENTRIC INFRARED PHOTOREFRACTOR; AGE-RELATED-CHANGES; CLINICAL-EVALUATION; REFRACTIVE ERROR; STATISTICAL-METHODS; GRAND SEIKO; POWERREFRACTOR; DYNAMICS; AGREEMENT; WAM-5500;
D O I
10.1097/OPX.0000000000000685
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To compare the static and dynamic accommodative responses measured with the WAM-5500 and the PowerRef-II autorefractors. Methods The dynamic and static monocular accommodative responses were measured with the WAM-5500 and the PowerRef-II instruments in 30 pre-presbyopic patients (23.66 [3.19] years). The spherical equivalent was measured at 0.00, 2.50, and 5.00 diopters (D) of accommodative stimulation for the static measurements. The subjective refraction was also determined. Dynamic accommodation was measured for abrupt changes of stimulus vergence of 2.00 D. Mean and peak velocities of accommodation and disaccommodation were evaluated. For the PowerRef-II, dynamic measurements were calculated for sampling frequencies of 5 and 25 Hz. Results For far distance static results, the differences between subjective and WAM-5500 measurements were 0.07 (+/- 0.21) D (p = 0.093) and those between subjective and PowerRef-II measurements were 0.70 (+/- 0.47) D (p = 0.001). The difference in the response measured with both instruments was 0.08 (+/- 0.32) D (p = 0.194) for 2.50 D and -0.32 (+/- 0.48) D (p = 0.001) for 5.00 D of stimulation. For the dynamic mode, the PowerRef-II at 25 Hz measured faster mean and peak velocities of accommodation and disaccommodation than the WAM-5500, with statistically significant (p < 0.05) differences of 0.68 (+/- 1.01), 0.67 (+/- 0.98), 1.26 (+/- 1.19), and 1.42 (+/- 1.53) D/s, respectively. With a sampling frequency of 5 Hz for the PowerRef-II, these differences, which were statistically significant (p < 0.05), were reduced to 0.52 (+/- 0.90), 0.49 (+/- 0.91), 0.83 (+/- 1.07), and 0.83 (+/- 1.31) D/s, respectively. Conclusions There is good agreement between subjective refraction and WAM-5500 measurements. In contrast, the PowerRef-II produced more hyperopic results. There were no differences among instruments at 2.50 D of static stimulation; however, differences were found at 5.00 D. In the dynamic measurements, the PowerRef-II measured faster velocities, partly attributed to the difference in the sampling frequency.
引用
收藏
页码:1003 / 1011
页数:9
相关论文
共 50 条
  • [41] THE ACCOMMODATIVE RESTING STATES, INSTRUMENT ACCOMMODATION AND THEIR MEASUREMENT
    SMITH, G
    OPTICA ACTA, 1983, 30 (03): : 347 - 359
  • [42] Objective measurement of accommodation using the COAS aberrometer
    Neal, DR
    Copland, J
    Rammage, RR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U708 - U708
  • [43] Improving performance measurement and benchmarking in the accommodation sector
    Bernini, Cristina
    Guizzardi, Andrea
    INTERNATIONAL JOURNAL OF CONTEMPORARY HOSPITALITY MANAGEMENT, 2015, 27 (05) : 980 - 1002
  • [44] Objective measurement of wavefront aberrations with and without accommodation
    Pallikaris, IG
    Panagopoulou, SI
    Siganos, CS
    Molebny, VV
    JOURNAL OF REFRACTIVE SURGERY, 2001, 17 (05) : S602 - S607
  • [45] Continuous measurement of accommodation in human factor applications
    Wolffsohn, JS
    Hunt, OA
    Gilmartin, B
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2002, 22 (05) : 380 - 384
  • [46] Accommodation study via a sensorless measurement technique
    Tellini, B.
    Giannetti, R.
    Lizon-Martinez, S.
    Marracci, M.
    PHYSICA B-CONDENSED MATTER, 2008, 403 (2-3) : 482 - 485
  • [47] MEASUREMENT OF VISUAL FATIGUE BY CHANGES IN ACCOMMODATION AND CONVERGENCE
    KRIVOHLAVY, J
    CESKOSLOVENSKA PSYCHOLOGIE, 1967, 11 (04): : 347 - 352
  • [48] Measurement of accommodation response in integral photography images
    Yano, Sumio
    Imai, Hiromichi
    Park, Min-Chul
    OPTICAL ENGINEERING, 2018, 57 (06)
  • [49] Measurement System of Accommodation and Convergence At the Same Time
    Yokoyama, Yuki
    Mochiduki, Shinya
    Takahira, Hideaki
    Yamada, Mitsuho
    2015 IEEE 4TH GLOBAL CONFERENCE ON CONSUMER ELECTRONICS (GCCE), 2015, : 217 - 220
  • [50] About the design of measurement systems and fault accommodation
    Maquin, D.
    Luong, M.
    Ragot, J.
    Engineering Simulation, 1996, 13 (06): : 1009 - 1024