Comparing Autorefractors for Measurement of Accommodation

被引:26
|
作者
Aldaba, Mikel [1 ]
Gomez-Lopez, Selena [1 ]
Vilaseca, Meritxell [1 ]
Pujol, Jaume [1 ]
Arjona, Montserrat [1 ]
机构
[1] Univ Politecn Cataluna, Ctr Sensors Instruments & Syst Dev CD6, Barcelona, Spain
关键词
accommodation; accommodative response; static; dynamic; WAM-5500; PowerRef-II; ECCENTRIC INFRARED PHOTOREFRACTOR; AGE-RELATED-CHANGES; CLINICAL-EVALUATION; REFRACTIVE ERROR; STATISTICAL-METHODS; GRAND SEIKO; POWERREFRACTOR; DYNAMICS; AGREEMENT; WAM-5500;
D O I
10.1097/OPX.0000000000000685
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To compare the static and dynamic accommodative responses measured with the WAM-5500 and the PowerRef-II autorefractors. Methods The dynamic and static monocular accommodative responses were measured with the WAM-5500 and the PowerRef-II instruments in 30 pre-presbyopic patients (23.66 [3.19] years). The spherical equivalent was measured at 0.00, 2.50, and 5.00 diopters (D) of accommodative stimulation for the static measurements. The subjective refraction was also determined. Dynamic accommodation was measured for abrupt changes of stimulus vergence of 2.00 D. Mean and peak velocities of accommodation and disaccommodation were evaluated. For the PowerRef-II, dynamic measurements were calculated for sampling frequencies of 5 and 25 Hz. Results For far distance static results, the differences between subjective and WAM-5500 measurements were 0.07 (+/- 0.21) D (p = 0.093) and those between subjective and PowerRef-II measurements were 0.70 (+/- 0.47) D (p = 0.001). The difference in the response measured with both instruments was 0.08 (+/- 0.32) D (p = 0.194) for 2.50 D and -0.32 (+/- 0.48) D (p = 0.001) for 5.00 D of stimulation. For the dynamic mode, the PowerRef-II at 25 Hz measured faster mean and peak velocities of accommodation and disaccommodation than the WAM-5500, with statistically significant (p < 0.05) differences of 0.68 (+/- 1.01), 0.67 (+/- 0.98), 1.26 (+/- 1.19), and 1.42 (+/- 1.53) D/s, respectively. With a sampling frequency of 5 Hz for the PowerRef-II, these differences, which were statistically significant (p < 0.05), were reduced to 0.52 (+/- 0.90), 0.49 (+/- 0.91), 0.83 (+/- 1.07), and 0.83 (+/- 1.31) D/s, respectively. Conclusions There is good agreement between subjective refraction and WAM-5500 measurements. In contrast, the PowerRef-II produced more hyperopic results. There were no differences among instruments at 2.50 D of static stimulation; however, differences were found at 5.00 D. In the dynamic measurements, the PowerRef-II measured faster velocities, partly attributed to the difference in the sampling frequency.
引用
收藏
页码:1003 / 1011
页数:9
相关论文
共 50 条
  • [31] CLINICAL-EVALUATION OF A RANGE OF AUTOREFRACTORS
    MCCAGHREY, GE
    MATTHEWS, FE
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1993, 13 (02) : 129 - 137
  • [33] Improving Predictive Models for Noncycloplegic Binocular Autorefractors
    Patil, Thayjas
    Sharma, Pranav
    Modjesky, Heather
    Silbert, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [34] Can autorefractors be trusted to test for myopia in children?
    Isenberg, SJ
    Del Signore, M
    Madani-Becker, G
    MYOPIA UPDATES II, 2000, : 87 - 87
  • [36] Study of measurement and calculation of the relative amplitude of accommodation
    Coloma, Pilar
    Pascual, Inmaculada
    de Fez, Dolores
    Camps, Vicente
    8TH IBEROAMERICAN OPTICS MEETING AND 11TH LATIN AMERICAN MEETING ON OPTICS, LASERS, AND APPLICATIONS, 2013, 8785
  • [37] Survey on measurement of tangential momentum accommodation coefficient
    Agrawal, Amit
    Prabhu, S. V.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2008, 26 (04): : 634 - 645
  • [38] A New Animal Model for the Measurement of Gastric Accommodation
    Sakurai, Jun
    Koseki, Junichi
    Kondo, Takashi
    Tanaka, Junji
    Hayashi, Chizuko
    Tomita, Toshihiko
    Kim, Yongmin
    Oshima, Tadayuki
    Hori, Kazutoshi
    Matsumoto, Takayuki
    Miwa, Hiroto
    GASTROENTEROLOGY, 2009, 136 (05) : A578 - A578
  • [39] Simplifying the measurement of gastric accommodation using SPECT
    Vijayvargiya, P.
    Camilleri, M.
    Shin, A.
    Breen, M.
    Burton, D.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2013, 25 (06): : 542 - 546
  • [40] Measurement of the lens accommodation in viewing stereoscopic displays
    Hong, Hyungki
    Kang, Seok Hyon
    JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2015, 23 (01) : 19 - 26