Impact of Patient-Prosthesis Mismatch in the Aortic Position: Twenty-Year Experience with Korean Patients

被引:0
|
作者
Jeong, Dong Seop [1 ]
Chang, Hyoung Woo [2 ]
Kim, Kyung-Hwan [2 ]
Ahn, Hyuk [2 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Thorac & Cardiovasc Surg, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Thorac & Cardiovasc Surg, Seoul 110744, South Korea
来源
JOURNAL OF HEART VALVE DISEASE | 2013年 / 22卷 / 01期
关键词
LONG-TERM SURVIVAL; DOPPLER-ECHOCARDIOGRAPHIC EVALUATION; LEFT-VENTRICULAR DYSFUNCTION; VALVE-REPLACEMENT; HEMODYNAMIC PERFORMANCE; MORTALITY; STENOSIS; VALIDATION; GUIDELINES; ANNULUS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: The impact of patient-prosthesis mismatch (PPM) on clinical outcomes following aortic valve replacement (AVR) remains controversial. The study aim was to evaluate the impact of PPM on long-term clinical outcomes following AVR. Methods: Between January 1987 and September 2007, a total of 198 consecutive patients (mean age 59.6 +/- 10.5 years; range: 31-85 years) underwent isolated AVR for pure aortic stenosis at the authors' institutions. PPM was defined as an indexed effective orifice area (EOAI) <0.85cm(2)/m(2), and was present in 45 patients (22.7%). The mean follow up duration was 102.6 +/- 71.6 months (maximum 270 months). Results: The early mortality was 1.5% (n = 3). The late mortality was similar in both the PPM and non-PPM groups (4.4% versus 4.7%; p = 0.950). The left ventricular mass index during follow up was higher in the PPM group (128.5 +/- 36.1 versus 114.5 +/- 39.1 g/m(2), p = 0.037). Freedom from cardiac-related mortality at 15 years was 86.5 +/- 4.3% in the non-PPM group, and 92.9 +/- 4.9% in the PPM group (p = 0.282). Freedom from heart failure events at 15 years was 74.6 +/- 6.6% in the non-PPM group and 61.6 +/- 8.5% in the PPM group (p = 0.028). Predictors of heart failure events were female gender (p = 0.041, hazards ratio (HR) = 2.5, 95% confidence interval (CI) = 1.1-5.9) and PPM (p = 0.001, HR = 5.1, 95% CI = 1.9-13.7). Conclusion: In AVR patients with pure aortic stenosis, PPM, when defined by the threshold value of EOAI <0.85 cm(2)/m(2), was not associated with differences in cardiac-related mortality. However, PPM was related to an increased incidence of postoperative heart failure events.
引用
收藏
页码:56 / 63
页数:8
相关论文
共 50 条
  • [41] Etiology of Patient-Prosthesis Mismatch in Aortic Valve Surgery: Implications for Cardioplegia
    Thubrikar, M. J.
    Ghosh, M.
    Fowler, B.
    Robicsek, F.
    CARDIOLOGY, 2010, 115 (04) : 291 - 291
  • [42] Twenty-year experience with the St. Jude Medical Biocor bioprosthesis in the aortic position
    Eichinger, W.
    AORTIC ROOT SURGERY: THE BIOLOGICAL SOLUTION, 2010, : 452 - 462
  • [43] Twenty-year experience with the St. Jude Medical Biocor bioprosthesis in the aortic position
    Eichinger, Walter B.
    Hettich, Ina M.
    Ruzicka, Daniel J.
    Holper, Klaus
    Schricker, Carolin
    Bleiziffer, Sabine
    Lange, Ruediger
    ANNALS OF THORACIC SURGERY, 2008, 86 (04): : 1204 - 1211
  • [44] AORTIC ROOT ENLARGEMENT IN REDO AORTIC VALVE REPLACEMENT WITH PREDICTED PATIENT-PROSTHESIS MISMATCH
    Chauvette, Vincent
    Senechal, Mario
    Barrette, Vincent
    Voisine, Pierre
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1330 - 1330
  • [45] Predicting patient-prosthesis mismatch by aortic root evaluation before aortic valve replacement
    Maeda, Koichi
    Kuratani, Toru
    Yoshioka, Daisuke
    Pak, Kyongsun
    Shimamura, Kazuo
    Toda, Koichi
    Sawa, Yoshiki
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 158 (01): : 61 - +
  • [46] Twenty-year experience with aortic valve replacement in children
    Lupinetti, FM
    Duncan, BW
    Dyamenahalli, U
    Rosenthal, GL
    CIRCULATION, 2002, 106 (19) : 395 - 395
  • [47] Abdominal aortic aneurysms: A twenty-year clinical experience
    Valdes, F
    Kramer, A
    Mertens, R
    Santini, A
    Canessa, R
    Lema, G
    Urzua, J
    Garayar, B
    Vergara, J
    Rivera, D
    REVISTA MEDICA DE CHILE, 1997, 125 (04) : 425 - 432
  • [48] Sizing matters: the outcome of patients with patient-prosthesis mismatch after transcatheter aortic valve implantation
    Polat, E.
    Mach, M.
    Santer, D.
    Pisarik, H.
    Folkmann, S.
    Harrer, M.
    Pollak, J.
    Adlbrecht, C.
    Veit, F.
    Delle Karth, G.
    Grabenwoeger, M.
    WIENER KLINISCHE WOCHENSCHRIFT, 2015, 127 : S47 - S47
  • [49] Patient-prosthesis mismatch in the mitral position affects midterm survival and functional status
    Bouchard, Denis
    Vanden Eynden, Frederic
    Demers, Philippe
    Perrault, Louis P.
    Carrier, Michel
    Cartier, Raymond
    Basmadjian, Arsene J.
    Pellerin, Michel
    CANADIAN JOURNAL OF CARDIOLOGY, 2010, 26 (10) : 532 - 536
  • [50] Patient-Prosthesis Mismatch in Patients With Aortic Stenosis Undergoing Isolated Aortic Valve Replacement Does Not Affect Survival
    Howell, Neil J.
    Keogh, Bruce E.
    Ray, Daniel
    Bonser, Robert S.
    Graham, Tim R.
    Mascaro, Jorge
    Rooney, Stephen J.
    Wilson, Ian C.
    Pagano, Domenico
    ANNALS OF THORACIC SURGERY, 2010, 89 (01): : 60 - 64