Impact of Patient-Prosthesis Mismatch in the Aortic Position: Twenty-Year Experience with Korean Patients

被引:0
|
作者
Jeong, Dong Seop [1 ]
Chang, Hyoung Woo [2 ]
Kim, Kyung-Hwan [2 ]
Ahn, Hyuk [2 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Thorac & Cardiovasc Surg, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Thorac & Cardiovasc Surg, Seoul 110744, South Korea
来源
JOURNAL OF HEART VALVE DISEASE | 2013年 / 22卷 / 01期
关键词
LONG-TERM SURVIVAL; DOPPLER-ECHOCARDIOGRAPHIC EVALUATION; LEFT-VENTRICULAR DYSFUNCTION; VALVE-REPLACEMENT; HEMODYNAMIC PERFORMANCE; MORTALITY; STENOSIS; VALIDATION; GUIDELINES; ANNULUS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: The impact of patient-prosthesis mismatch (PPM) on clinical outcomes following aortic valve replacement (AVR) remains controversial. The study aim was to evaluate the impact of PPM on long-term clinical outcomes following AVR. Methods: Between January 1987 and September 2007, a total of 198 consecutive patients (mean age 59.6 +/- 10.5 years; range: 31-85 years) underwent isolated AVR for pure aortic stenosis at the authors' institutions. PPM was defined as an indexed effective orifice area (EOAI) <0.85cm(2)/m(2), and was present in 45 patients (22.7%). The mean follow up duration was 102.6 +/- 71.6 months (maximum 270 months). Results: The early mortality was 1.5% (n = 3). The late mortality was similar in both the PPM and non-PPM groups (4.4% versus 4.7%; p = 0.950). The left ventricular mass index during follow up was higher in the PPM group (128.5 +/- 36.1 versus 114.5 +/- 39.1 g/m(2), p = 0.037). Freedom from cardiac-related mortality at 15 years was 86.5 +/- 4.3% in the non-PPM group, and 92.9 +/- 4.9% in the PPM group (p = 0.282). Freedom from heart failure events at 15 years was 74.6 +/- 6.6% in the non-PPM group and 61.6 +/- 8.5% in the PPM group (p = 0.028). Predictors of heart failure events were female gender (p = 0.041, hazards ratio (HR) = 2.5, 95% confidence interval (CI) = 1.1-5.9) and PPM (p = 0.001, HR = 5.1, 95% CI = 1.9-13.7). Conclusion: In AVR patients with pure aortic stenosis, PPM, when defined by the threshold value of EOAI <0.85 cm(2)/m(2), was not associated with differences in cardiac-related mortality. However, PPM was related to an increased incidence of postoperative heart failure events.
引用
收藏
页码:56 / 63
页数:8
相关论文
共 50 条
  • [31] Impact of Patient-Prosthesis Mismatch on Long-term Outcomes After Aortic Valve Replacement
    Graser, Michaela
    Bleiziffer, Sabine
    Zittermann, Armin
    Mayr, Benedikt
    Sideris, Konstantinos
    Puluca, Nazan
    Krane, Markus
    Prinzing, Anatol
    ANNALS OF THORACIC SURGERY, 2024, 118 (05):
  • [32] PATIENT-PROSTHESIS MISMATCH ON OCTOGENARIANS AFTER AORTIC VALVE REPLACEMENT: IMPACT ON EARLY AND LATE MORTALITY
    Buu-Khanh Lam
    Elmestekawy, Elsayed
    Lapierre, Harry
    Tran, Diem T.
    Ruel, Marc
    Mesana, Thierry G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1364 - E1364
  • [33] Hemodynamic performance and incidence of patient-prosthesis mismatch of the complete supraannular Perimount Magna bioprosthesis in the aortic position
    Botzenhardt, F
    Eichinger, WB
    Guenzinger, R
    Bleiziffer, S
    Wagner, I
    Bauernschmitt, R
    Lange, R
    THORACIC AND CARDIOVASCULAR SURGEON, 2005, 53 (04): : 226 - 230
  • [34] The Impact of Patient-Prosthesis Mismatch on Atrial and Ventricular Remodeling After Transcatheter Aortic Valve Replacement
    Poulin, Frederic
    Horlick, Eric M.
    Woo, Anna
    Thavendiranathan, Paaladinesh
    CIRCULATION, 2013, 128 (22)
  • [35] Subvalvular stenosis at repeat aortic valve replacement for patient-prosthesis mismatch
    Girard, SE
    Miller, FA
    Edwards, WD
    Tazelaar, HD
    Mahoney, DW
    Malouf, YF
    Tajik, AJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 534A - 534A
  • [36] Early outcomes of patient-prosthesis mismatch following aortic valve replacement
    Aitaliyev, Serik
    Rumbinaite, Egle
    Melinyte-Ankudavice, Karolina
    Nekrosius, Rokas
    Keturakis, Vytenis
    Benetis, Rimantas
    PERFUSION-UK, 2022, 37 (07): : 692 - 699
  • [37] Impact of patient-prosthesis mismatch and aortic valve design on coronary flow reserve after aortic valve replacement
    Bakhtiary, Farhad
    Schiemann, Mirko
    Dzemali, Omer
    Dogan, Selami
    Schaechinger, Volker
    Ackermann, Hans
    Moritz, Anton
    Kleine, Peter
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (07) : 790 - 796
  • [38] Stentless bioprostheses in small aortic roots: Impact patient-prosthesis mismatch on survival and quality life
    Ennker, J
    Rosendahl, U
    Albert, A
    Dumlu, E
    Ennker, IC
    Florath, I
    JOURNAL OF HEART VALVE DISEASE, 2005, 14 (04): : 523 - 530
  • [39] Measured or Predicted Patient-Prosthesis Mismatch Following Aortic Valve Replacement
    Abushouk, Abdelrahman I.
    Aglan, Amro
    Mahana, Ingy A.
    Puri, Rishi
    Krishnaswamy, Amar
    Reed, Grant W.
    Yun, James
    Kapadia, Samir R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (11) : 1428 - 1430
  • [40] Patient-Prosthesis Mismatch and Strategies to Prevent It During Aortic Valve Replacement
    Apostolakis, Efstratios
    Baikoussis, Nikolaos G.
    Papakonstantinou, Nikolaos A.
    Goudevenos, John
    HELLENIC JOURNAL OF CARDIOLOGY, 2011, 52 (01) : 41 - 51