Impact of Patient-Prosthesis Mismatch in the Aortic Position: Twenty-Year Experience with Korean Patients

被引:0
|
作者
Jeong, Dong Seop [1 ]
Chang, Hyoung Woo [2 ]
Kim, Kyung-Hwan [2 ]
Ahn, Hyuk [2 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Thorac & Cardiovasc Surg, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Thorac & Cardiovasc Surg, Seoul 110744, South Korea
来源
JOURNAL OF HEART VALVE DISEASE | 2013年 / 22卷 / 01期
关键词
LONG-TERM SURVIVAL; DOPPLER-ECHOCARDIOGRAPHIC EVALUATION; LEFT-VENTRICULAR DYSFUNCTION; VALVE-REPLACEMENT; HEMODYNAMIC PERFORMANCE; MORTALITY; STENOSIS; VALIDATION; GUIDELINES; ANNULUS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: The impact of patient-prosthesis mismatch (PPM) on clinical outcomes following aortic valve replacement (AVR) remains controversial. The study aim was to evaluate the impact of PPM on long-term clinical outcomes following AVR. Methods: Between January 1987 and September 2007, a total of 198 consecutive patients (mean age 59.6 +/- 10.5 years; range: 31-85 years) underwent isolated AVR for pure aortic stenosis at the authors' institutions. PPM was defined as an indexed effective orifice area (EOAI) <0.85cm(2)/m(2), and was present in 45 patients (22.7%). The mean follow up duration was 102.6 +/- 71.6 months (maximum 270 months). Results: The early mortality was 1.5% (n = 3). The late mortality was similar in both the PPM and non-PPM groups (4.4% versus 4.7%; p = 0.950). The left ventricular mass index during follow up was higher in the PPM group (128.5 +/- 36.1 versus 114.5 +/- 39.1 g/m(2), p = 0.037). Freedom from cardiac-related mortality at 15 years was 86.5 +/- 4.3% in the non-PPM group, and 92.9 +/- 4.9% in the PPM group (p = 0.282). Freedom from heart failure events at 15 years was 74.6 +/- 6.6% in the non-PPM group and 61.6 +/- 8.5% in the PPM group (p = 0.028). Predictors of heart failure events were female gender (p = 0.041, hazards ratio (HR) = 2.5, 95% confidence interval (CI) = 1.1-5.9) and PPM (p = 0.001, HR = 5.1, 95% CI = 1.9-13.7). Conclusion: In AVR patients with pure aortic stenosis, PPM, when defined by the threshold value of EOAI <0.85 cm(2)/m(2), was not associated with differences in cardiac-related mortality. However, PPM was related to an increased incidence of postoperative heart failure events.
引用
收藏
页码:56 / 63
页数:8
相关论文
共 50 条
  • [21] Patient-prosthesis mismatch after aortic valve replacement in the elderly
    Ryomoto M.
    Mitsuno M.
    Yamamura M.
    Tanaka H.
    Kobayashi Y.
    Fukui S.
    Tsujiya N.
    Kajiyama T.
    Miyamoto Y.
    General Thoracic and Cardiovascular Surgery, 2008, 56 (7) : 330 - 334
  • [22] Benchmarking Outcomes: Reoperation for Aortic Valve Patient-Prosthesis Mismatch
    Keeling, William B.
    Beckerman, Ziv
    Wei, Jane
    Binongo, Jose
    Leshnower, Bradley G.
    Chen, Edward P.
    ANNALS OF THORACIC SURGERY, 2021, 111 (05): : 1472 - 1477
  • [23] Surgical versus transcatheter aortic valve replacement: Impact of patient-prosthesis mismatch on outcomes
    Alnajar, Ahmed
    Hamad, Naser
    Azhar, Muhammad Z.
    Mousa, Yaseen
    Arora, Yingyot
    Lamelas, Joseph
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (12) : 5388 - 5394
  • [24] The effect of patient-prosthesis mismatch on survival after aortic and mitral valve replacement: a 10 year, single institution experience
    Sudeep Das De
    Ashok Nanjappa
    Karim Morcos
    Sadia Aftab
    John Butler
    Vivek Pathi
    Philip Curry
    Sukumaran Nair
    Journal of Cardiothoracic Surgery, 14
  • [25] Does the use of stentless aortic valves in a subcoronary position prevent patient-prosthesis mismatch for small aortic annulus?
    Lopez, Stephane
    Mathieu, Patrick
    Pibarot, Philippe
    Mohammadi, Siamak
    Dagenais, Francois
    Voisine, Pierre
    Dumesnil, Jean
    Doyle, Daniel
    JOURNAL OF CARDIAC SURGERY, 2008, 23 (04) : 331 - 335
  • [26] Twenty-Year Experience With the CarboMedics Mechanical Valve Prosthesis
    Bouchard, Denis
    Mazine, Amine
    Stevens, Louis-Mathieu
    Pellerin, Michel
    Cartier, Raymond
    Demers, Philippe
    Hebert, Yves
    Perrault, Louis P.
    Carrier, Michel
    Lambert, Jean
    ANNALS OF THORACIC SURGERY, 2014, 97 (03): : 816 - 823
  • [27] Patient-prosthesis mismatch increases the mean platelet volume in patients with aortic valve replacement
    Bayram, Huseyin
    Hidiroglu, Mete
    Cetin, Levent
    Cicek, Omer Faruk
    Kucuker, Aslihan
    Uguz, Emrah
    Erdogan, Kemal Esref
    Sener, Erol
    SURGERY TODAY, 2015, 45 (05) : 559 - 563
  • [28] Patient-prosthesis mismatch after minimally invasive aortic valve replacement
    Filip, Grzegorz
    Litwinowicz, Radoslaw
    Kapelak, Boguslaw
    Bryndza, Magdalena
    Bartus, Magdalena
    Konstanty-Kalandyk, Janusz
    Ceranowicz, Piotr
    Brzezinski, Maciej
    Gafoor, Sameer
    Bartus, Krzysztof
    KARDIOLOGIA POLSKA, 2018, 76 (05) : 908 - 910
  • [29] Impact of Left Ventricular Function on Patient-Prosthesis Mismatch Post Transcatheter Aortic Valve Replacement
    Chen, Kai
    James, Taylor Michiko
    Rothenberg, Mark
    Kapilla, Arvind
    Faber, Cristiano
    Nores, Marcos A.
    Stamou, Sotiris C.
    JOURNAL OF CARDIAC FAILURE, 2019, 25 (08) : S41 - S41
  • [30] Patient-prosthesis mismatch affects survival after aortic valve replacement
    Rao, V
    Jamieson, WRE
    Ivanov, J
    Armstrong, S
    David, TE
    CIRCULATION, 1999, 100 (18) : 461 - 461