4-D ICE: A 2-D Array Transducer With Integrated ASIC in a 10-Fr Catheter for Real-Time 3-D Intracardiac Echocardiography

被引:72
|
作者
Wildes, Douglas [1 ]
Lee, Warren [1 ]
Haider, Bruno [1 ,2 ]
Cogan, Scott [1 ,3 ]
Sundaresan, Krishnakumar [1 ]
Mills, David M. [1 ]
Yetter, Christopher [1 ]
Hart, Patrick H. [1 ,4 ]
Haun, Christopher R. [1 ]
Concepcion, Mikael [5 ,6 ]
Kirkhorn, Johan [7 ]
Bitoun, Marc [8 ]
机构
[1] GE Global Res, Niskayuna, NY 12309 USA
[2] GE Healthcare, Phoenix, AZ 85040 USA
[3] Michigan State Univ, E Lansing, MI 48824 USA
[4] GE Fuel Cells, Malta, NY 12020 USA
[5] Thomas Med Prod, Malvern, PA 19355 USA
[6] Merit Med Syst Inc, Malvern, PA 19355 USA
[7] GE Vingmed Ultrasound, N-3191 Horten, Norway
[8] Shifamed LLC, Campbell, CA 95008 USA
关键词
Application-specific integrated circuit (ASIC); catheters; four-dimensional (4-D); intracardiac; three-dimensional (3-D); two-dimensional (2-D) array; ultrasonic transducer arrays; ATRIAL SEPTAL-DEFECT; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; DEVICE CLOSURE; INITIAL-EXPERIENCE; MATRIX TRANSDUCER; ULTRASOUND; ABLATION; SYSTEM; INTERVENTIONS; FEASIBILITY;
D O I
10.1109/TUFFC.2016.2615602
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We developed a 2.5x6.6 mm(2) 2-D array transducer with integrated transmit/receive application-specific integrated circuit (ASIC) for real-time 3-D intracardiac echocardiography (4-D ICE) applications. The ASIC and transducer design were optimized so that the high-voltage transmit, low-voltage time-gain control and preamp, subaperture beamformer, and digital control circuits for each transducer element all fit within the 0.019-mm(2) area of the element. The transducer assembly was deployed in a 10-Fr (3.3-mm diameter) catheter, integrated with a GE Vivid E9 ultrasound imaging system, and evaluated in three preclinical studies. The 2-D image quality and imaging modes were comparable to commercial 2-D ICE catheters. The 4-D field of view was at least 90 degrees x 60 degrees x 8 cm and could be imaged at 30 vol/s, sufficient to visualize cardiac anatomy and other diagnostic and therapy catheters. 4-D ICE should significantly reduce X-ray fluoroscopy use and dose during electrophysiology ablation procedures. 4-D ICE may be able to replace transesophageal echocardiography (TEE), and the associated risks and costs of general anesthesia, for guidance of some structural heart procedures.
引用
收藏
页码:2159 / 2173
页数:15
相关论文
共 50 条
  • [41] Performance and Crosstalk Evaluation of 2-D Array Piezoelectric Micromachined Ultrasonic Transducer with 3-D Finite Element Simulation
    He, Le-Ming
    Xu, Wei-Jiang
    Liu, Wen-Juan
    Wang, Xu-Bo
    Zhou, Jia
    Ren, Jun-Yan
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 792 - 795
  • [42] 256x256 2-D array transducer with row-column addressing for 3-D imaging
    Seo, Chi Hyang
    Yen, Jesse T.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 2381 - 2384
  • [43] A 256 x 256 2-D Array Transducer with Row-Column Addressing for 3-D Rectilinear Imaging
    Seo, Chi Hyung
    Yen, Jesse T.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (04) : 837 - 847
  • [44] QUANTIFICATION OF LEFT VENTRICULAR LINEAR, AREAL AND VOLUMETRIC DIMENSIONS: A PHANTOM AND IN VIVO COMPARISON OF 2-D AND REAL-TIME 3-D ECHOCARDIOGRAPHY WITH CARDIOVASCULAR MAGNETIC RESONANCE
    Polte, Christian L.
    Lagerstrand, Kerstin M.
    Gao, Sinsia A.
    Lamm, Carl R.
    Bech-Hanssen, Odd
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (07): : 1981 - 1990
  • [45] REAL-TIME SYSTOLIC ARRAY PROCESSOR FOR 2-D SPATIAL-FILTERING
    ABOULNASR, T
    STEENAART, W
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS, 1988, 35 (04): : 451 - 455
  • [46] 3-D Acoustic Tweezers Using a 2-D Matrix Array With Time-Multiplexed Traps
    Hu, Qi
    Ma, Teng
    Zhang, Qi
    Wang, Jimin
    Yang, Ye
    Cai, Feiyan
    Zheng, Hairong
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (12) : 3646 - 3653
  • [47] Dual lumen transducer probes for real-time 3-D interventional cardiac ultrasound
    Lee, W
    Idriss, SF
    Wolf, PD
    Smith, SW
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (09): : 1297 - 1304
  • [48] Real-Time 3-D Spectral Doppler Analysis With a Sparse Spiral Array
    Ramalli, Alessandro
    Boni, Enrico
    Giangrossi, Claudio
    Mattesini, Paolo
    Dallai, Alessandro
    Liebgott, Herve
    Tortoli, Piero
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (05) : 1742 - 1751
  • [49] ASIC -based architecture for the real-time computation of 2-D convolution with large kernel size
    Shao, Rui
    Zhong, Sheng
    Yan, Luxin
    MIPPR 2015: PARALLEL PROCESSING OF IMAGES AND OPTIMIZATION; AND MEDICAL IMAGING PROCESSING, 2015, 9814
  • [50] Double Ring Array Catheter for In Vivo Real-Time 3D Ultrasound
    Smith, Stephen W.
    Gardea, Paul
    Patel, Vivek
    Douglas, Stephen J.
    Wolf, Patrick D.
    ULTRASONIC IMAGING, 2014, 36 (03) : 167 - 176