4-D ICE: A 2-D Array Transducer With Integrated ASIC in a 10-Fr Catheter for Real-Time 3-D Intracardiac Echocardiography

被引:72
|
作者
Wildes, Douglas [1 ]
Lee, Warren [1 ]
Haider, Bruno [1 ,2 ]
Cogan, Scott [1 ,3 ]
Sundaresan, Krishnakumar [1 ]
Mills, David M. [1 ]
Yetter, Christopher [1 ]
Hart, Patrick H. [1 ,4 ]
Haun, Christopher R. [1 ]
Concepcion, Mikael [5 ,6 ]
Kirkhorn, Johan [7 ]
Bitoun, Marc [8 ]
机构
[1] GE Global Res, Niskayuna, NY 12309 USA
[2] GE Healthcare, Phoenix, AZ 85040 USA
[3] Michigan State Univ, E Lansing, MI 48824 USA
[4] GE Fuel Cells, Malta, NY 12020 USA
[5] Thomas Med Prod, Malvern, PA 19355 USA
[6] Merit Med Syst Inc, Malvern, PA 19355 USA
[7] GE Vingmed Ultrasound, N-3191 Horten, Norway
[8] Shifamed LLC, Campbell, CA 95008 USA
关键词
Application-specific integrated circuit (ASIC); catheters; four-dimensional (4-D); intracardiac; three-dimensional (3-D); two-dimensional (2-D) array; ultrasonic transducer arrays; ATRIAL SEPTAL-DEFECT; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; DEVICE CLOSURE; INITIAL-EXPERIENCE; MATRIX TRANSDUCER; ULTRASOUND; ABLATION; SYSTEM; INTERVENTIONS; FEASIBILITY;
D O I
10.1109/TUFFC.2016.2615602
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We developed a 2.5x6.6 mm(2) 2-D array transducer with integrated transmit/receive application-specific integrated circuit (ASIC) for real-time 3-D intracardiac echocardiography (4-D ICE) applications. The ASIC and transducer design were optimized so that the high-voltage transmit, low-voltage time-gain control and preamp, subaperture beamformer, and digital control circuits for each transducer element all fit within the 0.019-mm(2) area of the element. The transducer assembly was deployed in a 10-Fr (3.3-mm diameter) catheter, integrated with a GE Vivid E9 ultrasound imaging system, and evaluated in three preclinical studies. The 2-D image quality and imaging modes were comparable to commercial 2-D ICE catheters. The 4-D field of view was at least 90 degrees x 60 degrees x 8 cm and could be imaged at 30 vol/s, sufficient to visualize cardiac anatomy and other diagnostic and therapy catheters. 4-D ICE should significantly reduce X-ray fluoroscopy use and dose during electrophysiology ablation procedures. 4-D ICE may be able to replace transesophageal echocardiography (TEE), and the associated risks and costs of general anesthesia, for guidance of some structural heart procedures.
引用
收藏
页码:2159 / 2173
页数:15
相关论文
共 50 条
  • [31] Recent results using a 256 x 256 2-D array transducer for 3-D Rectilinear Imaging
    Seo, Chi Hyung
    Yen, Jesse T.
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1146 - 1149
  • [32] Real-Time 2-D Phased Array Vector Flow Imaging
    Holbek, Simon
    Hansen, Kristoffer Lindskov
    Fogh, Nikolaj
    Moshavegh, Ramin
    Olesen, Jacob Bjerring
    Nielsen, Michael Bachmann
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (07) : 1205 - 1213
  • [33] Real-time 3D transesophageal echocardiography in the guidance of atrial septal defect closure: Comparison with intracardiac and 2D transesophageal echocardiography
    Lodato, Joseph A.
    Cao, Qi Ling
    Weinert, Lynn
    Sugeng, Lissa
    Lang, Roberto M.
    Hijazi, Ziyad M.
    CIRCULATION, 2007, 116 (16) : 399 - 399
  • [34] Improved 2-D and 3-D intracardiac echocardiography in electrophysiologic mapping studies - First experiences with a new 9-F 9 Mhz ultrasound catheter
    Schneider, MA
    Weyerbrock, S
    Zrenner, B
    Blasini, R
    CIRCULATION, 1997, 96 (08) : 3280 - 3280
  • [35] Real-time integration of 2D intracardiac echocardiography and 3D electroanatomical mapping to guide ventricular tachycardia ablation
    Khaykin, Yaariv
    Skanes, Allan
    Whaley, Bonnie
    Hill, Carol
    Beardsall, Marianne
    Seabrook, Catherine
    Wulffhart, Zaev
    Oosthuizen, Richard
    Gula, Lorne
    Verma, Atul
    HEART RHYTHM, 2008, 5 (10) : 1396 - 1402
  • [36] From 2-D to 3-D to 4-D electron microscopy: an outline of the essence and promise of unconventional crystallography and spectroscopy
    Thomas, John Meurig
    CRYSTALLOGRAPHY REVIEWS, 2011, 17 (02) : 81 - 103
  • [37] REAL TIME INTEGRATION OF 2D INTRACARDIAC ECHOCARDIOGRAPHY AND 3D ELECTROANATOMICAL MAPPING TO GUIDE CATHETER ABLATION OF COMPLEX CARDIAC ARRHYTHMIAS
    Grossi, S.
    Bianchi, F.
    Riccardi, R.
    Dottori, S.
    Pirola, L.
    Conte, M. R.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 : S10 - S10
  • [38] Role of Real-Time transthoracic 3-D echocardiography in the assessment of mechanical asynchrony
    Liodakis, E
    Al Sharef, O
    Dawson, D
    Pearson, P
    Nihoyannopoulos, P
    CIRCULATION, 2004, 110 (17) : 632 - 632
  • [39] 3-D Ultrasound Imaging Performance of a Row-Column Addressed 2-D Array Transducer: A Measurement Study
    Rasmussen, Morten Fischer
    Jensen, Jorgen Arendt
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1452 - 1455
  • [40] Real-time 3-D hand posture estimation based on 2-D appearance retrieval using monocular camera
    Shimada, N
    Kimura, K
    Shirai, Y
    IEEE ICCV WORKSHOP ON RECOGNITION, ANALYSIS AND TRACKING OF FACES AND GESTURES IN REAL-TIME SYSTEMS, PROCEEDINGS, 2001, : 23 - 30