Normalized mean glandular dose computation from mammography using GATE: a validation study

被引:16
|
作者
Myronakis, Marios E. [1 ,2 ]
Zvelebil, Marketa [3 ]
Darambara, Dimitra G. [1 ,2 ]
机构
[1] Inst Canc Res, Div Radiotherapy & Imaging, London SW3 6JJ, England
[2] Royal Marsden NHS Fdn Trust, London SW3 6JJ, England
[3] Inst Canc Res, Breast Breakthrough Res Ctr, London SW3 6JB, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 07期
关键词
SIMULATION TOOLKIT; BREAST MODEL; DOSIMETRY; CT; MOLYBDENUM; RHODIUM; PET;
D O I
10.1088/0031-9155/58/7/2247
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Mean glandular dose (MGD) is the figure of merit to assess breast dose after a mammographic acquisition. The use of normalized MGD obtained from Monte Carlo computations with measured incident air kerma determines the MGD delivered to patients. The Geant4 Application for Tomographic Emission (GATE) toolkit is a modern Monte Carlo application specifically designed for medical imaging systems modelling. Although there is an increasing number of publications using GATE worldwide for a wide range of medical imaging and therapeutic applications, there is currently no means to obtain normalized MGD. In this work, the GATE toolkit is extended, through the development of two new modules, to provide normalized MGD information for compressed breast phantoms based on simple geometries. The normalized MGD values were validated against published work and provided results at half value layers lower than 0.3 and greater than 0.6 mmAl. In addition, the skin thickness and composition were considered. Normalized MGD was computed after substitution of the adipose layer surrounding the standard breast phantom with skin tissue and the relative difference is reported. Spectrum generation was facilitated by further development of previously published work by other authors. Validation of the new GATE extension showed good agreement with published data and can be used to assess breast dose from mammographic as well as more complex x-ray imaging techniques. Changing skin thickness and composition revealed substantial changes in normalized MGD specifically for compressed breast thickness different than 5 cm and a possible revision of the structure of the standard breast model may be necessary.
引用
收藏
页码:2247 / 2265
页数:19
相关论文
共 50 条
  • [21] Mean glandular dose in digital mammography: A dose calculation method comparison
    [J]. Suleiman, Moayyad E. (msul1801@uni.sydney.edu.au), 1600, SPIE (04):
  • [22] Analysis of Half-Value Layer and Average Glandular Dose for Mammography Using Gate
    Mohammed Talbi
    Mohammed Khalis
    Rajaa Sebihi
    Oussama Nhila
    M’hamed El Mansouri
    El Mahjoub Chakir
    Zakaria Tahiri
    [J]. Moscow University Physics Bulletin, 2021, 76 : S95 - S102
  • [23] Analysis of Half-Value Layer and Average Glandular Dose for Mammography Using Gate
    Talbi, Mohammed
    Khalis, Mohammed
    Sebihi, Rajaa
    Nhila, Oussama
    El Mansouri, M'hamed
    Chakir, El Mahjoub
    Tahiri, Zakaria
    [J]. MOSCOW UNIVERSITY PHYSICS BULLETIN, 2021, 76 (SUPPL 1) : S95 - S102
  • [24] A Mammography Phantom to Measure Mean Glandular Dose and Image Quality
    Lopez-Pineda, E.
    Ruiz-Trejo, C.
    Brandan, M. E.
    [J]. MEDICAL PHYSICS, 2014, 41 (06)
  • [25] Decreased breast compression using digital mammography at screen/film mean glandular dose
    Kimme-Smith, C
    Yee, TY
    Bassett, LW
    [J]. IWDM 2000: 5TH INTERNATIONAL WORKSHOP ON DIGITAL MAMMOGRAPHY, 2001, : 51 - 55
  • [26] A study of mean glandular dose during diagnostic mammography in Malaysia and some of the factors affecting it
    Jamal, N
    Ng, KH
    McLean, D
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (904): : 238 - 245
  • [27] Determination of mean glandular dose from routine mammography for two age groups of patients
    Kunosic, Suad
    Ceke, Denis
    Kopric, Mustafa
    Lincender, Lidija
    [J]. HEALTHMED, 2010, 4 (01): : 125 - 131
  • [28] Results of a 2011 national questionnaire for investigation of mean glandular dose from mammography in Japan
    Asada, Y.
    Suzuki, S.
    Minami, K.
    Shirakawa, S.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2014, 34 (01) : 125 - 132
  • [29] Image quality, threshold contrast and mean glandular dose in CR mammography
    Jakubiak, R. R.
    Gamba, H. R.
    Neves, E. B.
    Peixoto, J. E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (18): : 6565 - 6583
  • [30] Mammography equipment performance, image quality and mean glandular dose in Malta
    Borg, M.
    Badr, I.
    Royle, G. J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 156 (02) : 168 - 183