Analysis of Half-Value Layer and Average Glandular Dose for Mammography Using Gate

被引:2
|
作者
Talbi, Mohammed [1 ]
Khalis, Mohammed [1 ]
Sebihi, Rajaa [2 ]
Nhila, Oussama [3 ]
El Mansouri, M'hamed [3 ]
Chakir, El Mahjoub [3 ]
Tahiri, Zakaria [4 ]
机构
[1] Moulay Ismail Univ, Fac Sci, Phys Sci & Engn Dept, IRAP, POB 11201, Zitoune Meknes, Morocco
[2] Mohammed V Univ, Fac Sci, ESMAR, POB 1014, Rabat, Morocco
[3] Ibn Tofail Univ, Fac Sci, Dept Phys, MSPL, POB 133, Kenitra, Morocco
[4] Mohammed V Univ, Fac Med & Pharm Rabat, DSCLHS, Rabat 10100, Morocco
关键词
mammography; AGD; incident air Kerma; X-ray spectra; gate; Monte Carlo simulation; IPEM Report 78; analysis; molybdenum; rhodium; X-RAY-SPECTRA; DIAGNOSTIC-RADIOLOGY; COMPUTATION; DOSIMETRY; VALIDATION;
D O I
10.3103/S0027134922010179
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Absract Background: Screening mammography is an unavoidable method for detecting breast cancer. It is therefore imperative to ensure a quality examination. To optimize practices, it is necessary to control the relationship between the dose to the breast and the image quality, this can be achieved by the Average Glandular Dose (AGD). The objective of this study is to calculate the average absorbed breast dose during a mammography examination by MONTE CARLO simulation using the GATE code (GEANT4). Methods: In this study, we performed our modulation on a digital mammography screening machine. The validation of the modelled simulation configuration was obtained by comparing the modulated spectra with the spectra produced by IPEM SRS 78, and by calculating the HVL values in Al. Finally, the values of the average absorbed dose were studied using the Monte Carlo code GATE, the results were compared with the experimental measurements using a semiconductor detector (Radcal AGMS -DM+) and a MTM100 phantom. Result: Our calculated results for the average glandular dose were consistent with the results of the experimental measurement and the energy spectra produced by GATE were in good agreement with that produced by IPEM Report 78. Conclusion: It can be assumed that the dose received in Mammography is highly dependent on the energy spectrum of the beam. Our modeling for screening mammography using GATE can be applied to further dosimetric studies of the mammography radiation exposure to the breast.
引用
收藏
页码:S95 / S102
页数:8
相关论文
共 50 条
  • [1] Analysis of Half-Value Layer and Average Glandular Dose for Mammography Using Gate
    Mohammed Talbi
    Mohammed Khalis
    Rajaa Sebihi
    Oussama Nhila
    M’hamed El Mansouri
    El Mahjoub Chakir
    Zakaria Tahiri
    Moscow University Physics Bulletin, 2021, 76 : S95 - S102
  • [2] Half-value layer determination using thermoluminescent dosimeters for digital mammography
    Tung, C. J.
    Lin, M. T.
    Hsu, F. Y.
    Lee, J. H.
    Chu, C. H.
    Tsai, H. Y.
    RADIATION MEASUREMENTS, 2010, 45 (3-6) : 729 - 732
  • [3] ON THE MEASUREMENT OF HALF-VALUE LAYER IN FILM-SCREEN MAMMOGRAPHY
    WAGNER, LK
    ARCHER, BR
    CERRA, F
    MEDICAL PHYSICS, 1990, 17 (06) : 989 - 997
  • [4] DETERMINATION OF HALF-VALUE LAYER
    TROUT, ED
    KELLEY, JP
    LUCAS, AC
    RADIOLOGY, 1959, 73 (01) : 107 - 108
  • [5] DETERMINATION OF HALF-VALUE LAYER
    TROUT, ED
    KELLEY, JP
    LUCAS, AC
    AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1960, 84 (04): : 729 - 740
  • [6] MAILED THERMOLUMINESCENT DOSIMETER DETERMINATION OF ENTRANCE SKIN EXPOSURE AND HALF-VALUE LAYER IN MAMMOGRAPHY
    WOCHOS, JF
    FULLERTON, GD
    DEWERD, LA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1978, 131 (04) : 617 - 619
  • [7] Patient Specific Average Glandular Dose in Mammography
    Patel, V.
    Highnam, R.
    Tromans, C.
    Pizzutiello, R. J.
    Destounis, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [8] NORMALIZED AVERAGE GLANDULAR DOSE IN MAGNIFICATION MAMMOGRAPHY
    LIU, B
    GOODSITT, M
    CHAN, HP
    RADIOLOGY, 1995, 197 (01) : 27 - 32
  • [9] Method for the evaluation of a average glandular dose in mammography
    Okunade, AA
    MEDICAL PHYSICS, 2006, 33 (04) : 1153 - 1164
  • [10] Average glandular dose in routine mammography screening using a Sectra MicroDose Mammography unit
    Hemdal, B
    Herrnsdorf, L
    Andersson, I
    Bengtsson, G
    Heddson, B
    Olsson, M
    RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 436 - 443