Analysis of Half-Value Layer and Average Glandular Dose for Mammography Using Gate

被引:2
|
作者
Talbi, Mohammed [1 ]
Khalis, Mohammed [1 ]
Sebihi, Rajaa [2 ]
Nhila, Oussama [3 ]
El Mansouri, M'hamed [3 ]
Chakir, El Mahjoub [3 ]
Tahiri, Zakaria [4 ]
机构
[1] Moulay Ismail Univ, Fac Sci, Phys Sci & Engn Dept, IRAP, POB 11201, Zitoune Meknes, Morocco
[2] Mohammed V Univ, Fac Sci, ESMAR, POB 1014, Rabat, Morocco
[3] Ibn Tofail Univ, Fac Sci, Dept Phys, MSPL, POB 133, Kenitra, Morocco
[4] Mohammed V Univ, Fac Med & Pharm Rabat, DSCLHS, Rabat 10100, Morocco
关键词
mammography; AGD; incident air Kerma; X-ray spectra; gate; Monte Carlo simulation; IPEM Report 78; analysis; molybdenum; rhodium; X-RAY-SPECTRA; DIAGNOSTIC-RADIOLOGY; COMPUTATION; DOSIMETRY; VALIDATION;
D O I
10.3103/S0027134922010179
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Absract Background: Screening mammography is an unavoidable method for detecting breast cancer. It is therefore imperative to ensure a quality examination. To optimize practices, it is necessary to control the relationship between the dose to the breast and the image quality, this can be achieved by the Average Glandular Dose (AGD). The objective of this study is to calculate the average absorbed breast dose during a mammography examination by MONTE CARLO simulation using the GATE code (GEANT4). Methods: In this study, we performed our modulation on a digital mammography screening machine. The validation of the modelled simulation configuration was obtained by comparing the modulated spectra with the spectra produced by IPEM SRS 78, and by calculating the HVL values in Al. Finally, the values of the average absorbed dose were studied using the Monte Carlo code GATE, the results were compared with the experimental measurements using a semiconductor detector (Radcal AGMS -DM+) and a MTM100 phantom. Result: Our calculated results for the average glandular dose were consistent with the results of the experimental measurement and the energy spectra produced by GATE were in good agreement with that produced by IPEM Report 78. Conclusion: It can be assumed that the dose received in Mammography is highly dependent on the energy spectrum of the beam. Our modeling for screening mammography using GATE can be applied to further dosimetric studies of the mammography radiation exposure to the breast.
引用
收藏
页码:S95 / S102
页数:8
相关论文
共 50 条
  • [31] Assessment of average glandular dose in mammography practice of a teaching hospital in Ghana
    Kyei, Kofi Adesi
    Anim-Sampong, Samuel
    Ahulu, Eugene Nartey
    Antwi, William Kwadwo
    Daniels, Joseph
    PAN AFRICAN MEDICAL JOURNAL, 2024, 47
  • [32] Assessment of male patients? average glandular dose during mammography procedure
    Sulieman, Abdelmoneim
    Salah, Hasan
    Rabbaa, Mohammad
    Abuljoud, Mohammad
    Alkhorayef, M.
    Tahir, Dahlang
    Tamam, N.
    Saeed, Mohammed K.
    Bradley, D. A.
    APPLIED RADIATION AND ISOTOPES, 2023, 193
  • [33] Digital mammography screening: Average glandular dose and first performance parameters
    Weigel, S.
    Girnus, R.
    Czwoydzinski, J.
    Decker, T.
    Spital, S.
    Heindel, W.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2007, 179 (09): : 892 - 895
  • [34] Effect of filter on average glandular dose and image quality in digital mammography
    Songsaeng, C.
    Krisanachinda, A.
    Theerakul, K.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [35] Data analysis of average glandular dose in mammography toward revision of the diagnostic reference level of Japan
    Negishi, Toru
    Koba, Yusuke
    Shinsho, Kiyomitsu
    Fujise, Daisuke
    Sai, Masahiro
    Nishide, Hiroko
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (03) : 765 - 769
  • [37] Uncertainties in Half Value Layer Determination in Mammography
    Mijovic, S.
    Ivanovic, S.
    Bemelmans, F.
    Bosmans, H.
    9TH INTERNATIONAL PHYSICS CONFERENCE OF THE BALKAN PHYSICAL UNION (BPU-9), 2016, 1722
  • [38] Glandular dose indices using a glandular dose to air kerma volume histogram in mammography
    Shinohara, Sae
    Araki, Fujio
    Ohno, Takeshi
    MEDICAL PHYSICS, 2020, 47 (03) : 1340 - 1348
  • [39] AN EVALUATION OF INFLUENCE OF HALF-VALUE LAYER ON DIAGNOSTIC QUALITY OF INTRAORAL ROENTGENOGRAMS
    CRANDELL, CE
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1966, 21 (01): : 39 - &
  • [40] A simple method for evaluation of half-value layer variation in CT equipment
    Maia, AF
    Caldas, LVE
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06): : 1595 - 1601