A Dual-Layer TOF-DOI Detector Block for Whole-Body PET

被引:6
|
作者
Liu, Shitao [1 ]
An, Shaohui [1 ]
Li, Hongdi [1 ]
Wang, Chao [1 ]
Ramirez, Rocio A. [1 ]
Zhang, Yuxuan [1 ]
Baghaei, Hossain [1 ]
Wong, Wai-Hoi [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Expt Diagnost Imaging, Houston, TX 77030 USA
基金
美国国家卫生研究院;
关键词
Depth of interaction (DOI); lutetium gadolinium oxyorthosilicate (LGSO); lutetium yttrium orthosilicate (LYSO); photomultiplier quadrant sharing (PQS); positron emission tomography (PET); time of flight (TOF); OF-FLIGHT PET; POSITRON-EMISSION-TOMOGRAPHY; TIME RESOLUTION; DEPTH; SCINTILLATION; PERFORMANCE; INFORMATION; MODULES; ARRAY;
D O I
10.1109/TNS.2012.2210053
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We developed a dual-layer high-resolution detector block for whole-body positron-emission tomography systems. The top layer is a 13 x 13 array of lutetium yttrium orthosilicate (LYSO) crystals (2.85 x 2.85 x 10 mm(3)) and the bottom layer a 13 x 13 array of lutetium gadolinium oxyorthosilicate (LGSO) crystals (2.85 x 2.85 x 10 mm(3)). The LGSO layer was coupled to four Hamamatsu R11194HA photomultiplier tubes (PMTs) by a photomultiplier quadrant-sharing configuration. This block has both time-of-flight and depth-of-interaction functions. Using a Na-22 point source, the performance of this block was evaluated by coinciding with a reference detector which consisted of a 4 x 4 x 10 mm(3) LYSO crystal coupled to a Hamamatsu R9779 PMT. A total of 4.7% of the counts were mixed among the two layers. The LYSO layer had 11.4% energy resolution and 329 ps coincidence time resolution against the reference detector. The LGSO layer had 14.8% energy resolution and 356 ps coincidence time resolution against the reference detector.
引用
收藏
页码:1805 / 1808
页数:4
相关论文
共 50 条
  • [31] A γ-photon detector based on liquid light guide for whole-body PET
    Xie, S.
    Chen, J.
    Yang, M.
    Shi, H.
    Peng, Q.
    Xu, J.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [32] Quantitation of improvement in lesion detectability with whole-body oncologic TOF-PET
    El Fakhri, Georges
    Surti, Suleman
    Trott, Cathryn
    Scheuerman, Joshua
    Karp, Joel
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [33] Highly multiplexed SiPM signal readout for brain-dedicated TOF-DOI PET detectors
    Park, Haewook
    Lee, Jae Sung
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 68 : 117 - 123
  • [34] A conformal TOF-DOI Prism-PET prototype scanner for high-resolution quantitative neuroimaging
    Zeng, Xinjie
    Wang, Zipai
    Tan, Wanbin
    Petersen, Eric
    Cao, Xinjie
    LaBella, Andy
    Boccia, Anthony
    Franceschi, Dinko
    de Leon, Mony
    Chiang, Gloria Chia-Yi
    Qi, Jinyi
    Biegon, Anat
    Zhao, Wei
    Goldan, Amir H.
    MEDICAL PHYSICS, 2023, 50 (06) : 3401 - 3417
  • [35] Comparison of contrast-enhanced CT, dual-layer detector spectral CT, and whole-body MRI in suspected metastatic breast cancer: a prospective diagnostic accuracy study
    Buus, Thomas Winther
    Rasmussen, Finn
    Nellemann, Hanne Marie
    Logager, Vibeke
    Jensen, Anders Bonde
    Hauerslev, Katrine Rye
    Christiansen, Peer
    Pedersen, Erik Morre
    EUROPEAN RADIOLOGY, 2021, 31 (12) : 8838 - 8849
  • [36] A Low-Cost DOI Block Detector for PET
    Zhang, Yuxuan
    Baghaei, Hossain
    Yan, Han
    Wong, Wai-Hoi
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [37] Initial Clinical Experience using a digital PET Detector for whole-body oncologic PET/CT
    Knopp, Michael
    Binzel, Katherine
    Nagar, Veena
    Wright, Chadwick
    Bardos, Philip
    Knopp, Michelle
    Liu, Xiaoli
    Maniawski, Piotr
    Zhang, Jun
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [38] Comparison of contrast-enhanced CT, dual-layer detector spectral CT, and whole-body MRI in suspected metastatic breast cancer: a prospective diagnostic accuracy study
    Thomas Winther Buus
    Finn Rasmussen
    Hanne Marie Nellemann
    Vibeke Løgager
    Anders Bonde Jensen
    Katrine Rye Hauerslev
    Peer Christiansen
    Erik Morre Pedersen
    European Radiology, 2021, 31 : 8838 - 8849
  • [39] Development of a Whole-Body Dual Ring OpenPET for in-Beam PET
    Yoshida E.
    Tashima H.
    Shinaji T.
    Shimizu K.
    Wakizaka H.
    Mohammadi A.
    Nishikido F.
    Yamaya T.
    Yoshida, Eiji (yoshida.eiji@qst.go.jp), 1600, Institute of Electrical and Electronics Engineers Inc. (01): : 293 - 300
  • [40] Scatter-compensated geometrical components for detector normalization in whole-body PET
    Mizuta, T.
    Kitamura, K.
    Ishikawa, A.
    Ohtani, A.
    Tanaka, K.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2583 - +