A Dual-Layer TOF-DOI Detector Block for Whole-Body PET

被引:6
|
作者
Liu, Shitao [1 ]
An, Shaohui [1 ]
Li, Hongdi [1 ]
Wang, Chao [1 ]
Ramirez, Rocio A. [1 ]
Zhang, Yuxuan [1 ]
Baghaei, Hossain [1 ]
Wong, Wai-Hoi [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Expt Diagnost Imaging, Houston, TX 77030 USA
基金
美国国家卫生研究院;
关键词
Depth of interaction (DOI); lutetium gadolinium oxyorthosilicate (LGSO); lutetium yttrium orthosilicate (LYSO); photomultiplier quadrant sharing (PQS); positron emission tomography (PET); time of flight (TOF); OF-FLIGHT PET; POSITRON-EMISSION-TOMOGRAPHY; TIME RESOLUTION; DEPTH; SCINTILLATION; PERFORMANCE; INFORMATION; MODULES; ARRAY;
D O I
10.1109/TNS.2012.2210053
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We developed a dual-layer high-resolution detector block for whole-body positron-emission tomography systems. The top layer is a 13 x 13 array of lutetium yttrium orthosilicate (LYSO) crystals (2.85 x 2.85 x 10 mm(3)) and the bottom layer a 13 x 13 array of lutetium gadolinium oxyorthosilicate (LGSO) crystals (2.85 x 2.85 x 10 mm(3)). The LGSO layer was coupled to four Hamamatsu R11194HA photomultiplier tubes (PMTs) by a photomultiplier quadrant-sharing configuration. This block has both time-of-flight and depth-of-interaction functions. Using a Na-22 point source, the performance of this block was evaluated by coinciding with a reference detector which consisted of a 4 x 4 x 10 mm(3) LYSO crystal coupled to a Hamamatsu R9779 PMT. A total of 4.7% of the counts were mixed among the two layers. The LYSO layer had 11.4% energy resolution and 329 ps coincidence time resolution against the reference detector. The LGSO layer had 14.8% energy resolution and 356 ps coincidence time resolution against the reference detector.
引用
收藏
页码:1805 / 1808
页数:4
相关论文
共 50 条
  • [21] Optimization of Enhanced Energy Window on a Whole-Body DOI PET System
    Ohtani, Atsushi
    Tanaka, Kazumi
    Mizuta, Tetsuro
    Inoue, Yoshihiro
    Tonami, Hiromichi
    Ohi, Junichi
    Kitamura, Keishi
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3618 - +
  • [22] Detector characterization of Discovery ST whole-body PET scanner
    Williams, JJ
    McDaniel, DL
    Kim, CL
    West, LJ
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 717 - 721
  • [23] Efficiency of RPC detectors for whole-body human TOF-PET
    Blanco, A.
    Couceiro, M.
    Crespo, P.
    Ferreira, N. C.
    Marques, R. Ferreira
    Fonte, P.
    Lopes, L.
    Neves, J. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 602 (03): : 780 - 783
  • [24] A validated Geant4 model of a whole-body PET scanner with four-layer DOI detectors
    Ahmed, Abdella M.
    Chacon, Andrew
    Rutherford, Harley
    Akamatsu, Go
    Mohammadi, Akram
    Nishikido, Fumihiko
    Tashima, Hideaki
    Yoshida, Eiji
    Yamaya, Taiga
    Franklin, Daniel R.
    Rosenfeld, Anatoly
    Guatelli, Susanna
    Safavi-Naeini, Mitra
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23):
  • [25] New developments at INFN-LNS on TOF-DOI PET based on SiPM detectors
    Cosentino, L.
    Cusanno, F.
    De Leo, R.
    Di Venti, G.
    Finocchiaro, P.
    Garibaldi, F.
    Loddo, F.
    Meddi, F.
    Musico, P.
    Pappalardo, A.
    Perrino, R.
    Ranieri, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 : 10 - 12
  • [26] Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET
    Yeom, Jung Yeol
    Vinke, Ruud
    Levin, Craig S.
    MEDICAL PHYSICS, 2014, 41 (12)
  • [27] Whole-body dual-modality PET/CT and whole-body MRI for tumor staging in oncology
    Antoch, G
    Vogt, FM
    Freudenberg, LS
    Nazaradeh, F
    Goehde, SC
    Barkhausen, J
    Dahmen, G
    Bockisch, A
    Debatin, JF
    Ruehm, SG
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 290 (24): : 3199 - 3206
  • [28] A Time-Walk and Timing-Shift Correction Method for Dual-Ended Readout TOF-DOI PET Detectors
    Wang, Haibo
    Xie, Jiahao
    Qi, Jinyi
    Cherry, Simon R.
    Du, Junwei
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2025, 9 (03) : 277 - 283
  • [29] Comparison of whole-body MRI with whole-body dual-modality PET/CT for tumor staging in oncology
    Antoch, G
    Vogt, FM
    Lauenstein, TC
    Mueller, SP
    Ruehm, SG
    Debatin, JF
    RADIOLOGY, 2002, 225 : 659 - 659
  • [30] Advantage of the Four-Layer DOI Information in the Time Resolution for a TOF-PET Detector
    Tsuda, Tomoaki
    Kitamura, Keishi
    Ohi, Junichi
    Tonami, Hiromichi
    Satoh, Masanobu
    Kumazawa, Yoshihiko
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3201 - 3204