Comparison of gradient-recalled echo and spin-echo echo-planar imaging MR elastography in staging liver fibrosis: a meta-analysis

被引:46
|
作者
Kim, Yong Seek [1 ]
Jang, Yu Na [2 ]
Song, Ji Soo [3 ,4 ,5 ]
机构
[1] Yonsei Univ, Coll Med, Severance Hosp, Dept Radiol, Seoul, South Korea
[2] Catholic Univ Korea, Yeouido St Marys Hosp, Coll Med, Div Gastroenterol,Dept Internal Med, Seoul, South Korea
[3] Chonbuk Natl Univ, Med Sch & Hosp, Dept Radiol, 20 Geonji Ro, Jeonju 54907, Chonbuk, South Korea
[4] Chonbuk Natl Univ, Res Inst Clin Med, 20 Geonji Ro, Jeonju 54907, Chonbuk, South Korea
[5] Chonbuk Natl Univ Hosp, Biomed Res Inst, 20 Geonji Ro, Jeonju 54907, Chonbuk, South Korea
关键词
Fibrosis; Magnetic resonance elastography; Gradient-recalled echo; Spin-echo echo-planar; Meta-analysis; MAGNETIC-RESONANCE ELASTOGRAPHY; DIAGNOSTIC-TEST ACCURACY; CHRONIC HEPATITIS-B; TRANSIENT ELASTOGRAPHY; DISEASE; PERFORMANCE; STEATOSIS; SPECTROSCOPY;
D O I
10.1007/s00330-017-5149-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare the diagnostic performance of gradient-recalled echo-based magnetic resonance elastography (GRE-MRE) and spin-echo echo-planar imaging-based MRE (SE-EPI-MRE) in liver fibrosis staging. A systematic literature search was performed to identify studies involving the performance of MRE for the diagnosis of liver fibrosis. Pooled sensitivity, specificity, positive and negative likelihood ratios, the diagnostic odds ratio, and a summary receiver operating characteristic (ROC) curve were estimated by using a bivariate random effects model. Subgroup analyses were performed between different study characteristics. Twenty-six studies with a total of 3,200 patients were included in the meta-analysis. Pooled sensitivity and specificity of GRE-MRE and SE-EPI-MRE did not differ significantly. The area under the summary ROC curve for stage diagnosis of any (F >= 1), significant (F >= 2), advanced (F >= 3), and cirrhosis (F = 4) on GRE-MRE and SE-EPI-MRE were 0.93 versus 0.94, 0.95 versus 0.94, 0.94 versus 0.95, and 0.92 versus 0.93, respectively. Substantial heterogeneity was detected for both sequences. Both GRE and SE-EPI-MRE show high sensitivity and specificity for detection of each stage of liver fibrosis, without significant differences. Magnetic resonance elastography (MRE) may be useful for noninvasive evaluation of liver fibrosis in chronic liver disease. aEuro cent Pooled sensitivity and specificity of GRE-MRE and SE-EPI-MRE did not differ significantly. aEuro cent GRE-MRE and SE-EPI-MRE were highly accurate for detecting all stages of fibrosis. aEuro cent Due to better agreement and repeatability, GRE-MRE should be used first. aEuro cent In case of failure on GRE-MRE, SE-EPI-MRE should be used.
引用
收藏
页码:1709 / 1718
页数:10
相关论文
共 50 条
  • [41] Diffusion-weighted imaging of the brain: comparison of stimulated- and spin-echo echo-planar sequences
    S. Heiland
    O. Dietrich
    K. Sartor
    Neuroradiology, 2001, 43 : 442 - 447
  • [42] Diagnostic Performance of Spin-Echo Echo-Planar Imaging Magnetic Resonance Elastography in 3T System for Noninvasive Assessment of Hepatic Fibrosis
    Kim, Se Woo
    Lee, Jeong Min
    Park, Sungeun
    Joo, Ijin
    Yoon, Jeong Hee
    Chang, Won
    Kim, Haeryoung
    KOREAN JOURNAL OF RADIOLOGY, 2022, 23 (02) : 180 - 188
  • [43] MR IMAGING OF PARKINSON DISEASE WITH SPIN-ECHO AND GRADIENT-ECHO SEQUENCES
    BRAFFMAN, BH
    GROSSMAN, RI
    GOLDBERG, HI
    STERN, MB
    HURTIG, HI
    HACKNEY, DB
    BILANIUK, LT
    ZIMMERMAN, RA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (01) : 159 - 165
  • [44] MR IMAGING OF PARKINSON DISEASE WITH SPIN-ECHO AND GRADIENT-ECHO SEQUENCES
    BRAFFMAN, BH
    GROSSMAN, RI
    GOLDBERG, HI
    STERN, MB
    HURTIG, HI
    HACKNEY, DB
    BILANIUK, LT
    ZIMMERMAN, RA
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (06) : 1093 - 1099
  • [45] MAGNETIZATION PREPARED RAPID GRADIENT-ECHO (MP-RAGE) MR IMAGING OF THE LIVER - COMPARISON WITH SPIN-ECHO IMAGING
    DELANGE, EE
    MUGLER, JP
    BERTOLINA, JA
    GAY, SB
    JANUS, CL
    BROOKEMAN, JR
    MAGNETIC RESONANCE IMAGING, 1991, 9 (04) : 469 - 476
  • [46] ADRENAL MASSES IN PATIENTS WITH MALIGNANCY - PROSPECTIVE COMPARISON OF ECHO-PLANAR, FAST SPIN-ECHO, AND CHEMICAL-SHIFT MR-IMAGING
    SCHWARTZ, LH
    PANICEK, DM
    KOUTCHER, JA
    BROWN, KT
    GETRAJDMAN, GI
    HEELAN, RT
    BURT, M
    RADIOLOGY, 1995, 197 (02) : 421 - 425
  • [47] MR imaging of the rotator cuff mechanism: Comparison of spin-echo and turbo spin-echo sequences
    Sonin, AH
    Peduto, AJ
    Fitzgerald, SW
    Callahan, CM
    Bresler, ME
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) : 333 - 338
  • [48] Multi-shot echo-planar Flair imaging of brain tumors: comparison of spin-echo T1-weighted, fast spin-echo T2-weighted, and fast spin-echo Flair imaging
    Tomura, N
    Kato, K
    Takahashi, S
    Sashi, R
    Izumi, J
    Narita, K
    Watarai, J
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (02) : 65 - 72
  • [49] Gradient- and spin-echo MR imaging of the brain
    Patel, MR
    Klufas, RA
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1999, 20 (07) : 1381 - 1382
  • [50] T2-weighted MR imaging of prostate cancer: multishot echo-planar imaging vs fast spin-echo imaging
    Tamada, T
    Sone, T
    Nagai, K
    Jo, Y
    Gyoten, M
    Imai, S
    Kajihara, Y
    Fukunaga, M
    EUROPEAN RADIOLOGY, 2004, 14 (02) : 318 - 325