Comparison of gradient-recalled echo and spin-echo echo-planar imaging MR elastography in staging liver fibrosis: a meta-analysis

被引:46
|
作者
Kim, Yong Seek [1 ]
Jang, Yu Na [2 ]
Song, Ji Soo [3 ,4 ,5 ]
机构
[1] Yonsei Univ, Coll Med, Severance Hosp, Dept Radiol, Seoul, South Korea
[2] Catholic Univ Korea, Yeouido St Marys Hosp, Coll Med, Div Gastroenterol,Dept Internal Med, Seoul, South Korea
[3] Chonbuk Natl Univ, Med Sch & Hosp, Dept Radiol, 20 Geonji Ro, Jeonju 54907, Chonbuk, South Korea
[4] Chonbuk Natl Univ, Res Inst Clin Med, 20 Geonji Ro, Jeonju 54907, Chonbuk, South Korea
[5] Chonbuk Natl Univ Hosp, Biomed Res Inst, 20 Geonji Ro, Jeonju 54907, Chonbuk, South Korea
关键词
Fibrosis; Magnetic resonance elastography; Gradient-recalled echo; Spin-echo echo-planar; Meta-analysis; MAGNETIC-RESONANCE ELASTOGRAPHY; DIAGNOSTIC-TEST ACCURACY; CHRONIC HEPATITIS-B; TRANSIENT ELASTOGRAPHY; DISEASE; PERFORMANCE; STEATOSIS; SPECTROSCOPY;
D O I
10.1007/s00330-017-5149-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare the diagnostic performance of gradient-recalled echo-based magnetic resonance elastography (GRE-MRE) and spin-echo echo-planar imaging-based MRE (SE-EPI-MRE) in liver fibrosis staging. A systematic literature search was performed to identify studies involving the performance of MRE for the diagnosis of liver fibrosis. Pooled sensitivity, specificity, positive and negative likelihood ratios, the diagnostic odds ratio, and a summary receiver operating characteristic (ROC) curve were estimated by using a bivariate random effects model. Subgroup analyses were performed between different study characteristics. Twenty-six studies with a total of 3,200 patients were included in the meta-analysis. Pooled sensitivity and specificity of GRE-MRE and SE-EPI-MRE did not differ significantly. The area under the summary ROC curve for stage diagnosis of any (F >= 1), significant (F >= 2), advanced (F >= 3), and cirrhosis (F = 4) on GRE-MRE and SE-EPI-MRE were 0.93 versus 0.94, 0.95 versus 0.94, 0.94 versus 0.95, and 0.92 versus 0.93, respectively. Substantial heterogeneity was detected for both sequences. Both GRE and SE-EPI-MRE show high sensitivity and specificity for detection of each stage of liver fibrosis, without significant differences. Magnetic resonance elastography (MRE) may be useful for noninvasive evaluation of liver fibrosis in chronic liver disease. aEuro cent Pooled sensitivity and specificity of GRE-MRE and SE-EPI-MRE did not differ significantly. aEuro cent GRE-MRE and SE-EPI-MRE were highly accurate for detecting all stages of fibrosis. aEuro cent Due to better agreement and repeatability, GRE-MRE should be used first. aEuro cent In case of failure on GRE-MRE, SE-EPI-MRE should be used.
引用
收藏
页码:1709 / 1718
页数:10
相关论文
共 50 条
  • [21] MR IMAGING OF THE CAVERNOUS SINUS - VALUE OF SPIN-ECHO AND GRADIENT RECALLED ECHO IMAGES
    DANIELS, DL
    CZERVIONKE, LF
    BONNEVILLE, JF
    CATTIN, F
    MARK, LP
    PECH, P
    HENDRIX, LE
    SMITH, DF
    HAUGHTON, VM
    WILLIAMS, AL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (05) : 1009 - 1014
  • [22] Magnetic Resonance Elastography of Intervertebral Discs: Spin-Echo Echo-Planar Imaging Sequence Validation
    Co, Megan
    Dong, Huiming
    Boulter, Daniel J.
    Nguyen, Xuan, V
    Khan, Safdar N.
    Raterman, Brian
    Klamer, Brett
    Kolipaka, Arunark
    Walter, Benjamin A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (06) : 1722 - 1732
  • [23] Comparison of spin-echo echoplanar imaging and gradient recalled echo-based MR elastography at 3 Tesla with and without gadoxetic acid administration
    Kim, Yong Seek
    Song, Ji Soo
    Kannengiesser, Stephan
    Seo, Seung Young
    EUROPEAN RADIOLOGY, 2017, 27 (10) : 4120 - 4128
  • [24] Comparison of spin-echo echoplanar imaging and gradient recalled echo-based MR elastography at 3 Tesla with and without gadoxetic acid administration
    Yong Seek Kim
    Ji Soo Song
    Stephan Kannengiesser
    Seung Young Seo
    European Radiology, 2017, 27 : 4120 - 4128
  • [25] A tractography comparison between turboprop and spin-echo echo-planar diffusion tensor imaging
    Gui, Minzhi
    Peng, Huiling
    Carew, John D.
    Lesniak, Maciej S.
    Arfanakis, Konstantinos
    NEUROIMAGE, 2008, 42 (04) : 1451 - 1462
  • [26] Snapshot gradient-recalled echo-planar images of rat brains at long echo time at 9.4 T
    Lei, Hongxia
    Mlynarik, Vladimir
    Just, Nathalie
    Gruetter, Rolf
    MAGNETIC RESONANCE IMAGING, 2008, 26 (07) : 954 - 960
  • [27] Early Diagnosis and Severity Assessment of Acute Pancreatitis (AP) Using MR Elastography (MRE) With Spin-Echo Echo-Planar Imaging
    Shi, Yu
    Liu, Ying
    Liu, Yan-qing
    Gao, Feng
    Li, Jia-hui
    Li, Qiu-ju
    Guo, Qi-yong
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (05) : 1311 - 1319
  • [28] Technical success rates and reliability of spin-echo echo-planar imaging (SE-EPI) MR elastography in patients with chronic liver disease or liver cirrhosis
    Sang Lim Choi
    Eun Sun Lee
    Ara Ko
    Hyun Jeong Park
    Sung Bin Park
    Byung Ihn Choi
    Young Youn Cho
    Stephan Kannengiesser
    European Radiology, 2020, 30 : 1730 - 1737
  • [29] GRADIENT-ECHO MR IMAGING OF THE LUMBAR SPINE - COMPARISON WITH SPIN-ECHO TECHNIQUE
    WATANABE, AT
    TEITELBAUM, GP
    LUFKIN, RB
    TSURUDA, JS
    JINKINS, JR
    BRADLEY, WG
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (03) : 410 - 414
  • [30] Technical success rates and reliability of spin-echo echo-planar imaging (SE-EPI) MR elastography in patients with chronic liver disease or liver cirrhosis
    Choi, Sang Lim
    Lee, Eun Sun
    Ko, Ara
    Park, Hyun Jeong
    Park, Sung Bin
    Choi, Byung Ihn
    Cho, Young Youn
    Kannengiesser, Stephan
    EUROPEAN RADIOLOGY, 2020, 30 (03) : 1730 - 1737