Comparison of gradient-recalled echo and spin-echo echo-planar imaging MR elastography in staging liver fibrosis: a meta-analysis

被引:46
|
作者
Kim, Yong Seek [1 ]
Jang, Yu Na [2 ]
Song, Ji Soo [3 ,4 ,5 ]
机构
[1] Yonsei Univ, Coll Med, Severance Hosp, Dept Radiol, Seoul, South Korea
[2] Catholic Univ Korea, Yeouido St Marys Hosp, Coll Med, Div Gastroenterol,Dept Internal Med, Seoul, South Korea
[3] Chonbuk Natl Univ, Med Sch & Hosp, Dept Radiol, 20 Geonji Ro, Jeonju 54907, Chonbuk, South Korea
[4] Chonbuk Natl Univ, Res Inst Clin Med, 20 Geonji Ro, Jeonju 54907, Chonbuk, South Korea
[5] Chonbuk Natl Univ Hosp, Biomed Res Inst, 20 Geonji Ro, Jeonju 54907, Chonbuk, South Korea
关键词
Fibrosis; Magnetic resonance elastography; Gradient-recalled echo; Spin-echo echo-planar; Meta-analysis; MAGNETIC-RESONANCE ELASTOGRAPHY; DIAGNOSTIC-TEST ACCURACY; CHRONIC HEPATITIS-B; TRANSIENT ELASTOGRAPHY; DISEASE; PERFORMANCE; STEATOSIS; SPECTROSCOPY;
D O I
10.1007/s00330-017-5149-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare the diagnostic performance of gradient-recalled echo-based magnetic resonance elastography (GRE-MRE) and spin-echo echo-planar imaging-based MRE (SE-EPI-MRE) in liver fibrosis staging. A systematic literature search was performed to identify studies involving the performance of MRE for the diagnosis of liver fibrosis. Pooled sensitivity, specificity, positive and negative likelihood ratios, the diagnostic odds ratio, and a summary receiver operating characteristic (ROC) curve were estimated by using a bivariate random effects model. Subgroup analyses were performed between different study characteristics. Twenty-six studies with a total of 3,200 patients were included in the meta-analysis. Pooled sensitivity and specificity of GRE-MRE and SE-EPI-MRE did not differ significantly. The area under the summary ROC curve for stage diagnosis of any (F >= 1), significant (F >= 2), advanced (F >= 3), and cirrhosis (F = 4) on GRE-MRE and SE-EPI-MRE were 0.93 versus 0.94, 0.95 versus 0.94, 0.94 versus 0.95, and 0.92 versus 0.93, respectively. Substantial heterogeneity was detected for both sequences. Both GRE and SE-EPI-MRE show high sensitivity and specificity for detection of each stage of liver fibrosis, without significant differences. Magnetic resonance elastography (MRE) may be useful for noninvasive evaluation of liver fibrosis in chronic liver disease. aEuro cent Pooled sensitivity and specificity of GRE-MRE and SE-EPI-MRE did not differ significantly. aEuro cent GRE-MRE and SE-EPI-MRE were highly accurate for detecting all stages of fibrosis. aEuro cent Due to better agreement and repeatability, GRE-MRE should be used first. aEuro cent In case of failure on GRE-MRE, SE-EPI-MRE should be used.