Comparison of Whole Heart Computed Tomography Scanners for Image Quality Lower Radiation Dosing in Coronary Computed Tomography Angiography: The CONVERGE Registry

被引:7
|
作者
Patel, Nirali [1 ]
Li, Dong [1 ]
Nakanishi, Rine [1 ,2 ]
Fatima, Badiha [1 ]
Andreini, Daniele [3 ,4 ]
Pontone, Gianluca [3 ]
Conte, Edoardo [3 ]
O'Rourke, Rachael [5 ,6 ]
Jayawardena, Eranthi [1 ]
Hamilton-Craig, Christian [5 ,6 ]
Nimmagadda, Manojna [1 ]
Budoff, Matthew J. [1 ]
机构
[1] Angeles Biomed Res Inst, Dept Med, Torrance, CA 90502 USA
[2] Toho Univ, Dept Cardiovasc Med, Grad Sch Med, Tokyo, Japan
[3] IRCCS, Ctr Cardiol Monzino, Milan, Italy
[4] Univ Milan, Dept Clin Sci & Community Hlth, Cardiovasc Sect, Milan, Italy
[5] Prince Charles Hosp, Dept Med Imaging, Brisbane, Qld, Australia
[6] Univ Queensland, Brisbane, Qld, Australia
基金
美国国家卫生研究院;
关键词
Coronary computed tomographic angiography; image quality; diagnosis; cardiac CT; DIAGNOSTIC PERFORMANCE; MULTICENTER; PERFUSION; FLOW;
D O I
10.1016/j.acra.2019.01.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Novel technology in coronary computed tomographic angiography allows assessment of coronary artery disease with high image quality (10). There are currently two wide detector "whole heart" coverage scanners available, which avoid misregistration artifacts. However, there are no data directly comparing IQ between the two scanners. The aim of the current study is to investigate if IQ is different between the most scanners of GE and Toshiba broad detector scanners. Materials and Methods: Prospective, observational, multicenter international cohort study comparing 236 consecutive patients who underwent coronary computed tomographic angiography using whole-heart scanners; 126 patients on scanner S1 (Aquilion ONE Vision, Toshiba), and 110 patients on scanner S2 (Revolution CT, GE Healthcare). Hounsfield units were measured using regions of interest in the descending aorta at 6 points (cranial slice, level of the visualized first, second, third, and fourth spines, and the caudal slice). We also compared the coverage length (z-axis) of the full width field of view between a single rotation of the two scanners. Results: Evaluating mean CT attenuation values Hounsfield units through the scan range, are progressively reduced across the descending aorta in the S1 group, resulting in the larger difference of contrast brightness between the cranial and caudal slices compared to the S2 group (absolute difference: S2 13.0 +/- 4.4 vs S1 141.9 +/- 16.4, p < 0.0001; Percent difference: 19.3 +/- 2.1 vs 3.4 +/- 1.2, <0.0001). The standard deviation (SD) is similar at the cranial slice between the two scanners, however, the S1 group demonstrated higher SD-differential from cranial to caudal than S2 group. Median radiation exposure was significantly lower for the S2 scanner 1.50 +/- 0.75 mSv vs the 51 system 1.9 mSv (IQR 1.7-2.7 mSv) (p = 0.01). Z-axis coverage was larger for the S2 scanner 152.5 mm (244 slices x 0.625 mm/slice) than 133 mm for S1 (266 slices x 0.5 mm/slice). Conclusion: Although both "volume" scanners cover the whole heart z-axis with one beat, scans using the S1 scanner have a larger variability in attenuation values throughout the scan range, resulting in 20% increase in nonuniformity from cranial to caudal slice. Additionally, SD variation across the field of view, a metric of noise, is larger when using the S1 scanner vs the S2 scanner. These results indicate that the GE Revolution CT has more uniform contrast enhancement and more coverage, lower radiation and lower image noise compared to the Toshiba Aquilion ONE Vision system.
引用
收藏
页码:1443 / 1449
页数:7
相关论文
共 50 条
  • [41] Coronary computed tomography angiography in children
    Malone, LaDonna J.
    Morin, Cara E.
    Browne, Lorna P.
    PEDIATRIC RADIOLOGY, 2022, 52 (13) : 2498 - 2509
  • [42] Computed Tomography Angiography and Myocardial Computed Tomography Perfusion in Patients With Coronary Stents
    Rief, Matthias
    Zimmermann, Elke
    Stenzel, Fabian
    Martus, Peter
    Stangl, Karl
    Greupner, Johannes
    Knebel, Fabian
    Kranz, Anisha
    Schlattmann, Peter
    Laule, Michael
    Dewey, Marc
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (16) : 1476 - 1485
  • [43] Limitations of Computed Tomography Coronary Angiography
    Nissen, Steven E.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (25) : 2145 - 2147
  • [44] Coronary angiography with multislice computed tomography
    Dewey, M
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 294 (18): : 2298 - 2298
  • [45] Coronary computed tomography angiography using multislice computed tomography: Pitfalls and potential
    Bainer, ML
    Boese, JM
    MULTISLICE CT: A PRACTICAL GUIDE, 2001, : 111 - 117
  • [46] Can Coronary Computed Tomography Angiography Replace Invasive Angiography? Coronary Computed Tomography Angiography Cannot Replace Invasive Angiography
    Stefanini, Giulio G.
    Windecker, Stephan
    CIRCULATION, 2015, 131 (04) : 418 - 426
  • [47] A Comparison of the Image Quality and Radiation Dose With Routine Computed Tomography and the Latest Gemstone Spectral Imaging Combination of Different Scanning Protocols in Computed Tomography Angiography of the Kidney
    Zhao, Yong-Xia
    Suo, Hong-Na
    Zuo, Zi-Wei
    Xu, Ying-Jin
    Chang, Jin
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (02) : 263 - 270
  • [48] Computed Tomography Angiography with a 192-slice Dual-source Computed Tomography System: Improvements in Image Quality and Radiation Dose
    Linsen, Philip V. M.
    Coenen, Adriaan
    Lubbers, Marisa M.
    Dijkshoorn, Marcel L.
    Ouhlous, Mohamed
    Nieman, Koen
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2016, 6
  • [49] Impact of the heart rate on multislice computed tomography coronary angiography
    Nieman, K
    Rensing, BJ
    van Geuns, RJM
    Pattynama, PMT
    de Feyter, PJ
    EUROPEAN HEART JOURNAL, 2002, 23 : 144 - 144
  • [50] Deep learning image reconstruction algorithm: impact on image quality in coronary computed tomography angiography
    Domenico De Santis
    Tiziano Polidori
    Giuseppe Tremamunno
    Carlotta Rucci
    Giulia Piccinni
    Marta Zerunian
    Luca Pugliese
    Antonella Del Gaudio
    Gisella Guido
    Luca Barbato
    Andrea Laghi
    Damiano Caruso
    La radiologia medica, 2023, 128 : 434 - 444