Comparison of Whole Heart Computed Tomography Scanners for Image Quality Lower Radiation Dosing in Coronary Computed Tomography Angiography: The CONVERGE Registry

被引:7
|
作者
Patel, Nirali [1 ]
Li, Dong [1 ]
Nakanishi, Rine [1 ,2 ]
Fatima, Badiha [1 ]
Andreini, Daniele [3 ,4 ]
Pontone, Gianluca [3 ]
Conte, Edoardo [3 ]
O'Rourke, Rachael [5 ,6 ]
Jayawardena, Eranthi [1 ]
Hamilton-Craig, Christian [5 ,6 ]
Nimmagadda, Manojna [1 ]
Budoff, Matthew J. [1 ]
机构
[1] Angeles Biomed Res Inst, Dept Med, Torrance, CA 90502 USA
[2] Toho Univ, Dept Cardiovasc Med, Grad Sch Med, Tokyo, Japan
[3] IRCCS, Ctr Cardiol Monzino, Milan, Italy
[4] Univ Milan, Dept Clin Sci & Community Hlth, Cardiovasc Sect, Milan, Italy
[5] Prince Charles Hosp, Dept Med Imaging, Brisbane, Qld, Australia
[6] Univ Queensland, Brisbane, Qld, Australia
基金
美国国家卫生研究院;
关键词
Coronary computed tomographic angiography; image quality; diagnosis; cardiac CT; DIAGNOSTIC PERFORMANCE; MULTICENTER; PERFUSION; FLOW;
D O I
10.1016/j.acra.2019.01.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Novel technology in coronary computed tomographic angiography allows assessment of coronary artery disease with high image quality (10). There are currently two wide detector "whole heart" coverage scanners available, which avoid misregistration artifacts. However, there are no data directly comparing IQ between the two scanners. The aim of the current study is to investigate if IQ is different between the most scanners of GE and Toshiba broad detector scanners. Materials and Methods: Prospective, observational, multicenter international cohort study comparing 236 consecutive patients who underwent coronary computed tomographic angiography using whole-heart scanners; 126 patients on scanner S1 (Aquilion ONE Vision, Toshiba), and 110 patients on scanner S2 (Revolution CT, GE Healthcare). Hounsfield units were measured using regions of interest in the descending aorta at 6 points (cranial slice, level of the visualized first, second, third, and fourth spines, and the caudal slice). We also compared the coverage length (z-axis) of the full width field of view between a single rotation of the two scanners. Results: Evaluating mean CT attenuation values Hounsfield units through the scan range, are progressively reduced across the descending aorta in the S1 group, resulting in the larger difference of contrast brightness between the cranial and caudal slices compared to the S2 group (absolute difference: S2 13.0 +/- 4.4 vs S1 141.9 +/- 16.4, p < 0.0001; Percent difference: 19.3 +/- 2.1 vs 3.4 +/- 1.2, <0.0001). The standard deviation (SD) is similar at the cranial slice between the two scanners, however, the S1 group demonstrated higher SD-differential from cranial to caudal than S2 group. Median radiation exposure was significantly lower for the S2 scanner 1.50 +/- 0.75 mSv vs the 51 system 1.9 mSv (IQR 1.7-2.7 mSv) (p = 0.01). Z-axis coverage was larger for the S2 scanner 152.5 mm (244 slices x 0.625 mm/slice) than 133 mm for S1 (266 slices x 0.5 mm/slice). Conclusion: Although both "volume" scanners cover the whole heart z-axis with one beat, scans using the S1 scanner have a larger variability in attenuation values throughout the scan range, resulting in 20% increase in nonuniformity from cranial to caudal slice. Additionally, SD variation across the field of view, a metric of noise, is larger when using the S1 scanner vs the S2 scanner. These results indicate that the GE Revolution CT has more uniform contrast enhancement and more coverage, lower radiation and lower image noise compared to the Toshiba Aquilion ONE Vision system.
引用
收藏
页码:1443 / 1449
页数:7
相关论文
共 50 条
  • [21] Image Quality and Dose Reduction by Dual Source Computed Tomography Coronary Angiography: Protocol Comparison
    Forte, Ernesto
    Monti, Serena
    Parente, Chiara Anna
    Beyer, Lukas
    De Rosa, Roberto
    Infante, Teresa
    Cavaliere, Carlo
    Cademartiri, Filippo
    Salvatore, Marco
    Stroszczynski, Christian
    Tedeschi, Carlo
    DOSE-RESPONSE, 2018, 16 (04):
  • [22] COMPARISON OF RADIATION INDUCED DAMAGE BETWEEN COMPUTED TOMOGRAPHY ANGIOGRAPHY AND CONVENTIONAL CORONARY ANGIOGRAPHY
    Sahinarslan, A.
    Erbas, G.
    Baser, D.
    Akyel, A.
    Kocaman, S.
    Karer, D.
    Yuce, C.
    Ergun, M. A.
    Arac, M.
    Boyaci, B.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 147 : S60 - S60
  • [23] Evaluation of Image Quality for High Heart Rates for Coronary Computed Tomographic Angiography with Advancement in CT Technology: The CONVERGE Registry
    Abdelkarim, Ayman
    Roy, Sion K.
    Kinninger, April
    Salek, Azadeh
    Baranski, Olivia
    Andreini, Daniele
    Pontone, Gianluca
    Conte, Edoardo
    O'Rourke, Rachael
    Hamilton-Craig, Christian
    Budoff, Matthew J.
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (09)
  • [24] Comparison of radiation induced damage between computed tomography angiography and conventional coronary angiography
    Sahinarslan, A.
    Erbas, G.
    Kocaman, S.
    Baser, D.
    Akyel, A.
    Karaer, D.
    Yuce, C.
    Ergun, M. A.
    Arac, M.
    Boyaci, B.
    EUROPEAN HEART JOURNAL, 2011, 32 : 522 - 522
  • [25] Estimated radiation dose and image quality comparison of the scan protocols in dual-source computed tomography coronary angiography
    Karaarslan, Ercan
    Ulus, Sila
    Bavbek, Cengiz
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (04) : 407 - 414
  • [26] Image quality vs radiation dose of four cone beam computed tomography scanners
    Loubele, M.
    Jacobs, R.
    Maes, F.
    Denis, K.
    White, S.
    Coudyzer, W.
    Lambrichts, I.
    van Steenberghe, D.
    Suetens, P.
    DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (06) : 309 - 318
  • [27] Radiation dose and image quality in computed tomography
    Prokop, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (05): : 631 - 636
  • [28] Image quality and radiation exposure with low-contrast-dose computed tomography angiography of the lower extremities
    Assi, Abed Al Nasser
    POLISH JOURNAL OF RADIOLOGY, 2020, 85 : E169 - E173
  • [29] Image quality of noninvasive coronary angiography using multislice spiral computed tomography and electron-beam computed tomography -: Intraindividual comparison in an animal model
    Lembcke, A
    Wiese, TH
    Schnorr, J
    Wagner, S
    Mews, J
    Kroencke, TJ
    Enzweiler, CNH
    Hamm, B
    Taupitz, M
    INVESTIGATIVE RADIOLOGY, 2004, 39 (06) : 357 - 364
  • [30] Impact of left atrial enlargement on image quality in coronary computed tomography angiography
    Nguyen, Tien C.
    Ohyama, Yoshiaki
    Taketomi-Takahashi, Ayako
    Nguyen, Huong T.
    Sumiyoshi, Hisako
    Nakamura, Tetsuya
    Kurabayashi, Masahiko
    Tsushima, Yoshito
    CLINICAL IMAGING, 2022, 84 : 87 - 92