Comparison of Whole Heart Computed Tomography Scanners for Image Quality Lower Radiation Dosing in Coronary Computed Tomography Angiography: The CONVERGE Registry

被引:7
|
作者
Patel, Nirali [1 ]
Li, Dong [1 ]
Nakanishi, Rine [1 ,2 ]
Fatima, Badiha [1 ]
Andreini, Daniele [3 ,4 ]
Pontone, Gianluca [3 ]
Conte, Edoardo [3 ]
O'Rourke, Rachael [5 ,6 ]
Jayawardena, Eranthi [1 ]
Hamilton-Craig, Christian [5 ,6 ]
Nimmagadda, Manojna [1 ]
Budoff, Matthew J. [1 ]
机构
[1] Angeles Biomed Res Inst, Dept Med, Torrance, CA 90502 USA
[2] Toho Univ, Dept Cardiovasc Med, Grad Sch Med, Tokyo, Japan
[3] IRCCS, Ctr Cardiol Monzino, Milan, Italy
[4] Univ Milan, Dept Clin Sci & Community Hlth, Cardiovasc Sect, Milan, Italy
[5] Prince Charles Hosp, Dept Med Imaging, Brisbane, Qld, Australia
[6] Univ Queensland, Brisbane, Qld, Australia
基金
美国国家卫生研究院;
关键词
Coronary computed tomographic angiography; image quality; diagnosis; cardiac CT; DIAGNOSTIC PERFORMANCE; MULTICENTER; PERFUSION; FLOW;
D O I
10.1016/j.acra.2019.01.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Novel technology in coronary computed tomographic angiography allows assessment of coronary artery disease with high image quality (10). There are currently two wide detector "whole heart" coverage scanners available, which avoid misregistration artifacts. However, there are no data directly comparing IQ between the two scanners. The aim of the current study is to investigate if IQ is different between the most scanners of GE and Toshiba broad detector scanners. Materials and Methods: Prospective, observational, multicenter international cohort study comparing 236 consecutive patients who underwent coronary computed tomographic angiography using whole-heart scanners; 126 patients on scanner S1 (Aquilion ONE Vision, Toshiba), and 110 patients on scanner S2 (Revolution CT, GE Healthcare). Hounsfield units were measured using regions of interest in the descending aorta at 6 points (cranial slice, level of the visualized first, second, third, and fourth spines, and the caudal slice). We also compared the coverage length (z-axis) of the full width field of view between a single rotation of the two scanners. Results: Evaluating mean CT attenuation values Hounsfield units through the scan range, are progressively reduced across the descending aorta in the S1 group, resulting in the larger difference of contrast brightness between the cranial and caudal slices compared to the S2 group (absolute difference: S2 13.0 +/- 4.4 vs S1 141.9 +/- 16.4, p < 0.0001; Percent difference: 19.3 +/- 2.1 vs 3.4 +/- 1.2, <0.0001). The standard deviation (SD) is similar at the cranial slice between the two scanners, however, the S1 group demonstrated higher SD-differential from cranial to caudal than S2 group. Median radiation exposure was significantly lower for the S2 scanner 1.50 +/- 0.75 mSv vs the 51 system 1.9 mSv (IQR 1.7-2.7 mSv) (p = 0.01). Z-axis coverage was larger for the S2 scanner 152.5 mm (244 slices x 0.625 mm/slice) than 133 mm for S1 (266 slices x 0.5 mm/slice). Conclusion: Although both "volume" scanners cover the whole heart z-axis with one beat, scans using the S1 scanner have a larger variability in attenuation values throughout the scan range, resulting in 20% increase in nonuniformity from cranial to caudal slice. Additionally, SD variation across the field of view, a metric of noise, is larger when using the S1 scanner vs the S2 scanner. These results indicate that the GE Revolution CT has more uniform contrast enhancement and more coverage, lower radiation and lower image noise compared to the Toshiba Aquilion ONE Vision system.
引用
收藏
页码:1443 / 1449
页数:7
相关论文
共 50 条
  • [31] Coronary computed tomography angiography with prospective electrocardiography triggering: a systematic review of image quality and radiation dose
    Sabarudin, Akmal
    Sun, Zhonghua
    Ng, Kwan-Hoong
    SINGAPORE MEDICAL JOURNAL, 2013, 54 (01) : 15 - 23
  • [32] Computed Tomography Coronary Angiography Guidance in Invasive Coronary Angiography: A Prospective Registry Study
    van Beek, Konrad
    Bouwmeester, Sjoerd
    Tonino, Pim
    van Nunen, Lokien
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B124 - B124
  • [33] Plaque quantification by coronary computed tomography angiography using intravascular ultrasound as a reference standard: a comparison between standard and last generation computed tomography scanners
    Conte, Edoardo
    Mushtaq, Saima
    Pontone, Gianluca
    Li Piani, Letizia
    Ravagnani, Paolo
    Galli, Stefano
    Collet, Carlos
    Sonck, Jeroen
    Di Odoardo, Luca
    Guglielmo, Marco
    Baggiano, Andrea
    Trabattoni, Daniela
    Annoni, Andrea
    Mancini, Maria Elisabetta
    Formenti, Alberto
    Muscogiuri, Giuseppe
    Magatelli, Marco
    Nicoli, Flavia
    Poggi, Carlotta
    Fiorentini, Cesare
    Bartorelli, Antonio L.
    Pepi, Mauro
    Montorsi, Piero
    Andreini, Daniele
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2020, 21 (02) : 191 - 201
  • [34] Computed Tomography Angiography of the Lower Extremities
    Cook, Tessa Sundaram
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2016, 54 (01) : 115 - +
  • [35] Comparison of image quality in computed laminography and tomography
    Xu, Feng
    Helfen, Lukas
    Baumbach, Tilo
    Suhonen, Heikki
    OPTICS EXPRESS, 2012, 20 (02): : 794 - 806
  • [36] Whole-heart coronary magnetic resonance angiography: Value for the detection of coronary artery stenoses in comparison to multislice computed tomography angiography
    Maintz, D.
    Ozgun, M.
    Hoffmeier, A.
    Quante, M.
    Fischbach, R.
    Manning, W. J.
    Heindel, W.
    Botnar, R. M.
    ACTA RADIOLOGICA, 2007, 48 (09) : 967 - 973
  • [37] Lower Radiation Dosing in Cardiac CT Angiography: The CONVERGE Registry
    Madaj, Paul
    Li, Dong
    Nakanishi, Rine
    Andreini, Daniele
    Pontone, Gianluca
    Conte, Edoardo
    Franzcr, Rachael O'Rourke
    Hamilton-Craig, Christian
    Nimmagadda, Manojna
    Kim, Nicholas
    Fatima, Badiha
    Dailing, Christopher
    Budoff, Matthew J.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2020, 48 (01) : 58 - 62
  • [38] COMPARISON OF HIGH RESOLUTION COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY WITH CONVENTIONAL CORONARY ANGIOGRAPHY
    Khan, Sher Bahadar
    Ataullah
    Ali, Jabbar
    Rauf, Muhammad Abdur
    Gul, Adnan Mehmood
    Irfan, Muhammad
    Hafizullah, Muhammad
    PAKISTAN HEART JOURNAL, 2013, 46 (01): : 57 - 63
  • [39] Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography
    Coles, DR
    Smail, MA
    Negus, IS
    Wilde, P
    Oberhoff, M
    Karsch, KR
    Baumbach, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (09) : 1840 - 1845
  • [40] Coronary computed tomography angiography in children
    LaDonna J. Malone
    Cara E. Morin
    Lorna P. Browne
    Pediatric Radiology, 2022, 52 : 2498 - 2509