Comparison of Whole Heart Computed Tomography Scanners for Image Quality Lower Radiation Dosing in Coronary Computed Tomography Angiography: The CONVERGE Registry

被引:7
|
作者
Patel, Nirali [1 ]
Li, Dong [1 ]
Nakanishi, Rine [1 ,2 ]
Fatima, Badiha [1 ]
Andreini, Daniele [3 ,4 ]
Pontone, Gianluca [3 ]
Conte, Edoardo [3 ]
O'Rourke, Rachael [5 ,6 ]
Jayawardena, Eranthi [1 ]
Hamilton-Craig, Christian [5 ,6 ]
Nimmagadda, Manojna [1 ]
Budoff, Matthew J. [1 ]
机构
[1] Angeles Biomed Res Inst, Dept Med, Torrance, CA 90502 USA
[2] Toho Univ, Dept Cardiovasc Med, Grad Sch Med, Tokyo, Japan
[3] IRCCS, Ctr Cardiol Monzino, Milan, Italy
[4] Univ Milan, Dept Clin Sci & Community Hlth, Cardiovasc Sect, Milan, Italy
[5] Prince Charles Hosp, Dept Med Imaging, Brisbane, Qld, Australia
[6] Univ Queensland, Brisbane, Qld, Australia
基金
美国国家卫生研究院;
关键词
Coronary computed tomographic angiography; image quality; diagnosis; cardiac CT; DIAGNOSTIC PERFORMANCE; MULTICENTER; PERFUSION; FLOW;
D O I
10.1016/j.acra.2019.01.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Novel technology in coronary computed tomographic angiography allows assessment of coronary artery disease with high image quality (10). There are currently two wide detector "whole heart" coverage scanners available, which avoid misregistration artifacts. However, there are no data directly comparing IQ between the two scanners. The aim of the current study is to investigate if IQ is different between the most scanners of GE and Toshiba broad detector scanners. Materials and Methods: Prospective, observational, multicenter international cohort study comparing 236 consecutive patients who underwent coronary computed tomographic angiography using whole-heart scanners; 126 patients on scanner S1 (Aquilion ONE Vision, Toshiba), and 110 patients on scanner S2 (Revolution CT, GE Healthcare). Hounsfield units were measured using regions of interest in the descending aorta at 6 points (cranial slice, level of the visualized first, second, third, and fourth spines, and the caudal slice). We also compared the coverage length (z-axis) of the full width field of view between a single rotation of the two scanners. Results: Evaluating mean CT attenuation values Hounsfield units through the scan range, are progressively reduced across the descending aorta in the S1 group, resulting in the larger difference of contrast brightness between the cranial and caudal slices compared to the S2 group (absolute difference: S2 13.0 +/- 4.4 vs S1 141.9 +/- 16.4, p < 0.0001; Percent difference: 19.3 +/- 2.1 vs 3.4 +/- 1.2, <0.0001). The standard deviation (SD) is similar at the cranial slice between the two scanners, however, the S1 group demonstrated higher SD-differential from cranial to caudal than S2 group. Median radiation exposure was significantly lower for the S2 scanner 1.50 +/- 0.75 mSv vs the 51 system 1.9 mSv (IQR 1.7-2.7 mSv) (p = 0.01). Z-axis coverage was larger for the S2 scanner 152.5 mm (244 slices x 0.625 mm/slice) than 133 mm for S1 (266 slices x 0.5 mm/slice). Conclusion: Although both "volume" scanners cover the whole heart z-axis with one beat, scans using the S1 scanner have a larger variability in attenuation values throughout the scan range, resulting in 20% increase in nonuniformity from cranial to caudal slice. Additionally, SD variation across the field of view, a metric of noise, is larger when using the S1 scanner vs the S2 scanner. These results indicate that the GE Revolution CT has more uniform contrast enhancement and more coverage, lower radiation and lower image noise compared to the Toshiba Aquilion ONE Vision system.
引用
收藏
页码:1443 / 1449
页数:7
相关论文
共 50 条
  • [1] Image Quality in Computed Tomography Coronary Angiography and Radiation Dose Reduction
    Golubickas, Domas
    Lukosevicius, Saulius
    Tamakauskas, Vytenis
    Dobrovolskiene, Laima
    Baseviciene, Ingrida
    Grib, Liviu
    Ragaisyte, Nijole
    Leonavicius, Rytis
    Medvedev, Viktor
    Veikutis, Vincentas
    INFORMATICA, 2021, 32 (04) : 741 - 757
  • [2] Whole-Heart Coronary Angiography using Volume Computed Tomography in Comparison to Conventional Coronary Angiography
    Dewey, Marc
    Zimmermann, Elike
    Deissenrieder, Florian
    Laule, Michael
    Duebel, Hans-Peter
    Rutsch, Wolfgang
    Hamm, Bernd
    CIRCULATION, 2008, 118 (18) : S1006 - S1006
  • [3] Radiation dose and image quality with new protocol in lower extremity computed tomography angiography
    Schicchi, Nicolo
    Fogante, Marco
    Oliva, Matteo
    Pirani, Paolo Esposto
    Agliata, Giacomo
    Giuseppetti, Gian Marco
    Giovagnoni, Andrea
    RADIOLOGIA MEDICA, 2019, 124 (03): : 184 - 190
  • [4] Radiation dose and image quality with new protocol in lower extremity computed tomography angiography
    Nicolò Schicchi
    Marco Fogante
    Matteo Oliva
    Paolo Esposto Pirani
    Giacomo Agliata
    Gian Marco Giuseppetti
    Andrea Giovagnoni
    La radiologia medica, 2019, 124 : 184 - 190
  • [5] Image quality of coronary computed tomography angiography with 320-Row area detector computed tomography in children with congenital heart disease
    Qin, Jie
    Cai, Songwang
    Peng, Lingrong
    Tang, Wenjie
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (16) : C142 - C142
  • [6] Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease
    Akihiro Tada
    Shuhei Sato
    Yuichiro Kanie
    Takashi Tanaka
    Ryota Inai
    Noriaki Akagi
    Yusuke Morimitsu
    Susumu Kanazawa
    Pediatric Cardiology, 2016, 37 : 497 - 503
  • [7] Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease
    Tada, Akihiro
    Sato, Shuhei
    Kanie, Yuichiro
    Tanaka, Takashi
    Inai, Ryota
    Akagi, Noriaki
    Morimitsu, Yusuke
    Kanazawa, Susumu
    PEDIATRIC CARDIOLOGY, 2016, 37 (03) : 497 - 503
  • [8] Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners
    Suomalainen, A.
    Kiljunen, T.
    Kaser, Y.
    Peltola, J.
    Kortesniemi, M.
    DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (06) : 367 - 378
  • [9] Influence of cardiac function on image quality in coronary computed tomography angiography
    Nguyen, Tien C.
    Ohyama, Yoshiaki
    Taketomi-Takahashi, Ayako
    Nguyen, Huong T.
    Sugimoto, Akio
    Sato, Makito
    Sumiyoshi, Hisako
    Nakamura, Tetsuya
    Kurabayashi, Masahiko
    Tsushima, Yoshito
    CLINICAL IMAGING, 2019, 53 : 58 - 64
  • [10] Image Quality of 256-Slice Computed Tomography for Coronary Angiography
    Chao, Shu-Ping
    Leu, Jyh-Gang
    Law, Wai-Yip
    Kuo, Chu-Jen
    Shyu, Kou-Gi
    ACTA CARDIOLOGICA SINICA, 2013, 29 (05) : 444 - 450