The Relationship Between Polyethylene Wear and Periprosthetic Osteolysis in Total Hip Arthroplasty at 12 Years in a Randomized Controlled Trial Cohort

被引:44
|
作者
Broomfield, John A. J. [1 ]
Malak, Tamer T. [1 ]
Thomas, Geraint E. R. [1 ]
Palmer, Antony J. R. [1 ]
Taylor, Adrian [1 ]
Glyn-Jones, Sion [1 ]
机构
[1] Univ Oxford, Botnar Res Ctr, Nuffield Dept Orthopaed Rheumatol & Musculoskelet, Oxford OX3 7LD, England
来源
JOURNAL OF ARTHROPLASTY | 2017年 / 32卷 / 04期
关键词
primary total hip arthroplasty; polyethylene wear; periprosthetic osteolysis; highly cross-linked polyethylene; Computed Tomography; RSA; CROSS-LINKED POLYETHYLENE; MOLECULAR-WEIGHT POLYETHYLENE; TOTAL JOINT REPLACEMENTS; COMPUTED-TOMOGRAPHY; PELVIC OSTEOLYSIS; RADIOSTEREOMETRIC ANALYSIS; ACETABULAR OSTEOLYSIS; DOUBLE-BLIND; PARTICLES; FLUID;
D O I
10.1016/j.arth.2016.10.037
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Polyethylene acetabular components are common in hip arthroplasty. Highly cross-linked polyethylene (HXLPE) has lower wear than ultra-high molecular weight polyethylene (UHMWPE). Evidence suggests that wear particles induce inflammation causing periprosthetic osteolysis contributing to implant loosening with wear rates of 0.05 mm/y were considered safe. We aimed to compare incidence and volume of periacetabular osteolysis between HXLPE and UHMWPE using computed tomography. Methods: Initially, 54 hips in 53 patients were randomized to HXLPE or UHMWPE acetabular liner. At 10 years, 39 hips in 38 patients remained for the radiostereometric analysis' demonstrating significantly lower wear in the HXLPE group. At 12 years, 14 hips in 13 patients were lost to follow-up leaving 25 hips for computed tomography assessment. Images were reconstructed to detect osteolysis and where identified, areas were segmented and volumized. Results: Osteolysis was observed in 8 patients, 7 from the UHMWPE group and only 1 from the HXLPE group (Fisher exact, P = .042). There was no correlation between the amount of polyethylene wear and osteolysis volume; however, the radiostereometric analysis-measured wear rate in patients with osteolysis from both groups was significantly higher than overall average wear rate. Conclusion: This data demonstrates lower incidence of periacetabular osteolysis in the HXLPE group of a small cohort. Although numbers are too low to estimate causation, in the context of lower wear in the HXLPE group, this finding supports the hypothesis that HXLPE may not elevate osteolysis risk, and hence does not suggest that HXLPE wear particles are more biologically active than those generated by earlier generations of polyethylene. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1186 / 1191
页数:6
相关论文
共 50 条
  • [21] PERIPROSTHETIC BONE LOSS IN TOTAL HIP-ARTHROPLASTY - POLYETHYLENE WEAR DEBRIS AND THE CONCEPT OF THE EFFECTIVE JOINT SPACE
    SCHMALZRIED, TP
    JASTY, M
    HARRIS, WH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (06): : 849 - 863
  • [22] Creep and Wear in Vitamin E-Infused Highly Cross-Linked Polyethylene Cups for Total Hip Arthroplasty A Prospective Randomized Controlled Trial
    Rochcongar, G.
    Buia, G.
    Bourroux, E.
    Dunet, J.
    Chapus, V.
    Hulet, C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (02): : 107 - 114
  • [23] VOLUMETRIC PERI-PROSTHETIC OSTEOLYSIS IN TOTAL HIP ARTHROPLASTY MEASURED USING COMPUTED TOMOGRAPHY - A 12 YEAR PROSPECTIVE DOUBLE BLIND RANDOMIZED CONTROLLED TRIAL
    Broomfield, J. A.
    Malak, T. T.
    Palmer, A. J.
    Thomas, G. E.
    Taylor, A.
    Carr, A. J.
    Glyn-Jones, S.
    OSTEOARTHRITIS AND CARTILAGE, 2015, 23 : A409 - A410
  • [24] Comparison study of periprosthetic bone remodeling between simultaneous bilateral total hip arthroplasty and unilateral total hip arthroplasty: a matched cohort study
    Hayashi, Shinya
    Kuroda, Yuichi
    Nakano, Naoki
    Matsumoto, Tomoyuki
    Tachibana, Shotaro
    Kuroda, Ryosuke
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (11) : 2767 - 2772
  • [25] Comparison study of periprosthetic bone remodeling between simultaneous bilateral total hip arthroplasty and unilateral total hip arthroplasty: a matched cohort study
    Shinya Hayashi
    Yuichi Kuroda
    Naoki Nakano
    Tomoyuki Matsumoto
    Shotaro Tachibana
    Ryosuke Kuroda
    International Orthopaedics, 2023, 47 : 2767 - 2772
  • [26] Lack of Demographic Information in Total Hip Arthroplasty/Total Knee Arthroplasty Randomized Controlled Trial Publications
    Donnelly, Katelynn M.
    Theriot, Hannah G.
    Bourgeois, John P.
    Chapple, Andrew G.
    Krause, Peter C.
    Dasa, Vinod
    JOURNAL OF ARTHROPLASTY, 2023, 38 (03): : 573 - 577
  • [27] The relationship of polyethylene wear to particle size, distribution, and number: A possible factor explaining the risk of osteolysis after hip arthroplasty
    Gallo, Jiri
    Slouf, Miroslav
    Goodman, Stuart B.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2010, 94B (01) : 171 - 177
  • [28] Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: A randomized prospective trial
    Martell, JM
    Verner, JJ
    Incavo, SJ
    JOURNAL OF ARTHROPLASTY, 2003, 18 (07): : 55 - 59
  • [29] Fifteen-Year Comparison of Wear and Osteolysis Analysis for Cross-Linked or Conventional Polyethylene in Cementless Total Hip Arthroplasty for Hip Dysplasia-A Retrospective Cohort Study
    Tsukamoto, Manabu
    Ohnishi, Hideo
    Mori, Toshiharu
    Kawasaki, Makoto
    Uchida, Soshi
    Sakai, Akinori
    JOURNAL OF ARTHROPLASTY, 2017, 32 (01): : 161 - +
  • [30] Posterior Quadratus Lumborum Block in Total Hip Arthroplasty: A Randomized Controlled Trial
    Coppola, Silvia
    Caccioppola, Alessio
    Froio, Sara
    Chiumello, Davide
    ANESTHESIOLOGY, 2021, 134 (05) : 774 - 783