The Relationship Between Polyethylene Wear and Periprosthetic Osteolysis in Total Hip Arthroplasty at 12 Years in a Randomized Controlled Trial Cohort

被引:44
|
作者
Broomfield, John A. J. [1 ]
Malak, Tamer T. [1 ]
Thomas, Geraint E. R. [1 ]
Palmer, Antony J. R. [1 ]
Taylor, Adrian [1 ]
Glyn-Jones, Sion [1 ]
机构
[1] Univ Oxford, Botnar Res Ctr, Nuffield Dept Orthopaed Rheumatol & Musculoskelet, Oxford OX3 7LD, England
来源
JOURNAL OF ARTHROPLASTY | 2017年 / 32卷 / 04期
关键词
primary total hip arthroplasty; polyethylene wear; periprosthetic osteolysis; highly cross-linked polyethylene; Computed Tomography; RSA; CROSS-LINKED POLYETHYLENE; MOLECULAR-WEIGHT POLYETHYLENE; TOTAL JOINT REPLACEMENTS; COMPUTED-TOMOGRAPHY; PELVIC OSTEOLYSIS; RADIOSTEREOMETRIC ANALYSIS; ACETABULAR OSTEOLYSIS; DOUBLE-BLIND; PARTICLES; FLUID;
D O I
10.1016/j.arth.2016.10.037
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Polyethylene acetabular components are common in hip arthroplasty. Highly cross-linked polyethylene (HXLPE) has lower wear than ultra-high molecular weight polyethylene (UHMWPE). Evidence suggests that wear particles induce inflammation causing periprosthetic osteolysis contributing to implant loosening with wear rates of 0.05 mm/y were considered safe. We aimed to compare incidence and volume of periacetabular osteolysis between HXLPE and UHMWPE using computed tomography. Methods: Initially, 54 hips in 53 patients were randomized to HXLPE or UHMWPE acetabular liner. At 10 years, 39 hips in 38 patients remained for the radiostereometric analysis' demonstrating significantly lower wear in the HXLPE group. At 12 years, 14 hips in 13 patients were lost to follow-up leaving 25 hips for computed tomography assessment. Images were reconstructed to detect osteolysis and where identified, areas were segmented and volumized. Results: Osteolysis was observed in 8 patients, 7 from the UHMWPE group and only 1 from the HXLPE group (Fisher exact, P = .042). There was no correlation between the amount of polyethylene wear and osteolysis volume; however, the radiostereometric analysis-measured wear rate in patients with osteolysis from both groups was significantly higher than overall average wear rate. Conclusion: This data demonstrates lower incidence of periacetabular osteolysis in the HXLPE group of a small cohort. Although numbers are too low to estimate causation, in the context of lower wear in the HXLPE group, this finding supports the hypothesis that HXLPE may not elevate osteolysis risk, and hence does not suggest that HXLPE wear particles are more biologically active than those generated by earlier generations of polyethylene. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1186 / 1191
页数:6
相关论文
共 50 条
  • [31] POSTOPERATIVE BLOOD SALVAGE IN TOTAL HIP AND KNEE ARTHROPLASTY - A RANDOMIZED CONTROLLED TRIAL
    SLAGIS, SV
    BENJAMIN, JB
    VOLZ, RG
    GIORDANO, GF
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04): : 591 - 591
  • [32] Posterior Soft Tissue Repair in Total Hip Arthroplasty: A Randomized Controlled Trial
    Tarasevicius, Sarunas
    Robertsson, Otto
    Wingstrand, Hans
    ORTHOPEDICS, 2010, 33 (12)
  • [33] The relationship between femoral periprosthetic cortical bone geometry and porosity after total hip arthroplasty
    Chou, Teri G. Rosenbaum
    Child, Jeremy R.
    Naughtin, Ryan J.
    Rigdon, Ryan R.
    Schumann, Craig
    Bloebaum, Roy D.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2008, 87A (01) : 107 - 115
  • [34] No Difference in Periprosthetic Bone Loss and Fixation Between a Standard-Length Stem and a Shorter Version in Cementless Total Hip Arthroplasty. A Randomized Controlled Trial
    Schilcher, Jorg
    Ivarsson, Ingemar
    Perlbach, Rico
    Palm, Lars
    JOURNAL OF ARTHROPLASTY, 2017, 32 (04): : 1220 - 1226
  • [35] Conventional Polyethylene in Total Hip Arthroplasty in Young Patients: Survivorship, Wear Analysis, and Clinical Outcomes Between 15 and 20 Years
    Stambough, Jeffrey B.
    Rames, Richard D.
    Pashos, Gail E.
    Maloney, William J.
    Martell, John M.
    Clohisy, John C.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (12): : 3712 - 3718
  • [36] Polyethylene Wear and Osteolysis After Cement less Total Hip Arthroplasty with Alumina-on-Highly Cross-Linked Polyethylene Bearings in Patients Younger Than Thirty Years of Age
    Kim, Young-Hoo
    Park, Fang-Won
    Patel, Chirag
    Kim, Dae-Youn
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (12): : 1088 - 1093
  • [37] The Seven-Year Wear of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty A Double-Blind, Randomized Controlled Trial Using Radiostereometric Analysis
    Thomas, Geraint E. R.
    Simpson, David J.
    Mehmood, Shahid
    Taylor, Adrian
    McLardy-Smith, Peter
    Gill, Harinderjit Singh
    Murray, David W.
    Glyn-Jones, Sion
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (08): : 716 - 722
  • [38] Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial
    van der Veen, Hugo C.
    van den Akker-Scheek, Inge
    Bulstra, Sjoerd K.
    van Raay, Jos J. A. M.
    BMC MUSCULOSKELETAL DISORDERS, 2012, 13
  • [39] Highly Cross-Linked Polyethylene Reduces Wear and Revision Rates in Total Hip Arthroplasty A 10-Year Double-Blinded Randomized Controlled Trial
    Devane, Peter A.
    Horne, James Geoffrey
    Ashmore, Alexander
    Mutimer, Jonathon
    Kim, Woosung
    Stanley, James
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (20): : 1703 - 1714
  • [40] Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial
    Hugo C van der Veen
    Inge van den Akker-Scheek
    Sjoerd K Bulstra
    Jos JAM van Raay
    BMC Musculoskeletal Disorders, 13