The Relationship Between Polyethylene Wear and Periprosthetic Osteolysis in Total Hip Arthroplasty at 12 Years in a Randomized Controlled Trial Cohort

被引:44
|
作者
Broomfield, John A. J. [1 ]
Malak, Tamer T. [1 ]
Thomas, Geraint E. R. [1 ]
Palmer, Antony J. R. [1 ]
Taylor, Adrian [1 ]
Glyn-Jones, Sion [1 ]
机构
[1] Univ Oxford, Botnar Res Ctr, Nuffield Dept Orthopaed Rheumatol & Musculoskelet, Oxford OX3 7LD, England
来源
JOURNAL OF ARTHROPLASTY | 2017年 / 32卷 / 04期
关键词
primary total hip arthroplasty; polyethylene wear; periprosthetic osteolysis; highly cross-linked polyethylene; Computed Tomography; RSA; CROSS-LINKED POLYETHYLENE; MOLECULAR-WEIGHT POLYETHYLENE; TOTAL JOINT REPLACEMENTS; COMPUTED-TOMOGRAPHY; PELVIC OSTEOLYSIS; RADIOSTEREOMETRIC ANALYSIS; ACETABULAR OSTEOLYSIS; DOUBLE-BLIND; PARTICLES; FLUID;
D O I
10.1016/j.arth.2016.10.037
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Polyethylene acetabular components are common in hip arthroplasty. Highly cross-linked polyethylene (HXLPE) has lower wear than ultra-high molecular weight polyethylene (UHMWPE). Evidence suggests that wear particles induce inflammation causing periprosthetic osteolysis contributing to implant loosening with wear rates of 0.05 mm/y were considered safe. We aimed to compare incidence and volume of periacetabular osteolysis between HXLPE and UHMWPE using computed tomography. Methods: Initially, 54 hips in 53 patients were randomized to HXLPE or UHMWPE acetabular liner. At 10 years, 39 hips in 38 patients remained for the radiostereometric analysis' demonstrating significantly lower wear in the HXLPE group. At 12 years, 14 hips in 13 patients were lost to follow-up leaving 25 hips for computed tomography assessment. Images were reconstructed to detect osteolysis and where identified, areas were segmented and volumized. Results: Osteolysis was observed in 8 patients, 7 from the UHMWPE group and only 1 from the HXLPE group (Fisher exact, P = .042). There was no correlation between the amount of polyethylene wear and osteolysis volume; however, the radiostereometric analysis-measured wear rate in patients with osteolysis from both groups was significantly higher than overall average wear rate. Conclusion: This data demonstrates lower incidence of periacetabular osteolysis in the HXLPE group of a small cohort. Although numbers are too low to estimate causation, in the context of lower wear in the HXLPE group, this finding supports the hypothesis that HXLPE may not elevate osteolysis risk, and hence does not suggest that HXLPE wear particles are more biologically active than those generated by earlier generations of polyethylene. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1186 / 1191
页数:6
相关论文
共 50 条
  • [1] Periprosthetic osteolysis in total hip arthroplasty: The role of particulate wear debris
    Maloney, WJ
    Smith, RL
    INSTRUCTIONAL COURSE LECTURES, VOL 45, 1996, 1996, 45 : 171 - 182
  • [2] PERIPROSTHETIC OSTEOLYSIS IN TOTAL HIP-ARTHROPLASTY - THE ROLE OF PARTICULATE WEAR DEBRIS
    MALONEY, WJ
    SMITH, RL
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (09): : 1448 - 1461
  • [3] Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty
    Young, AM
    Sychterz, CJ
    Hopper, RH
    Engh, CA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (01): : 58 - 63
  • [4] Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty
    Sochart, DH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (363) : 135 - 150
  • [5] Wear Rate of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty A Randomized Controlled Trial
    McCalden, Richard W.
    MacDonald, Steven J.
    Rorabeck, Cecil H.
    Bourne, Robert B.
    Chess, David G.
    Charron, Kory D.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (04): : 773 - 782
  • [6] Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty
    Jiri Gallo
    Vitezslav Havranek
    Jana Zapletalova
    International Orthopaedics, 2010, 34 : 19 - 26
  • [7] Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty
    Gallo, Jiri
    Havranek, Vitezslav
    Zapletalova, Jana
    INTERNATIONAL ORTHOPAEDICS, 2010, 34 (01) : 19 - 26
  • [8] Catastrophic Periprosthetic Osteolysis in Total Hip Arthroplasty at 20 Years: A Case Report and Literature Review
    Xing, Dan
    Li, Rujun
    Li, Jiao Jiao
    Tao, Ke
    Lin, Jianhao
    Yan, Taiqiang
    Zhou, Diange
    ORTHOPAEDIC SURGERY, 2022, 14 (08) : 1918 - 1926
  • [9] A literature review of the association between wear rate and osteolysis in total hip arthroplasty
    Dumbleton, JH
    Manley, MT
    Edidin, AA
    JOURNAL OF ARTHROPLASTY, 2002, 17 (05): : 649 - 661
  • [10] Early polyethylene wear and osteolysis in cementless total hip arthroplasty - The influence of femoral head size and polyethylene thickness
    Lee, PC
    Shih, CH
    Chen, WJ
    Tu, YK
    Tai, CL
    JOURNAL OF ARTHROPLASTY, 1999, 14 (08): : 976 - 981