Monte carlo modeling of penetration effect for iodine-131 pinhole imaging

被引:10
|
作者
Wang, HL
Jaszczak, RJ
Coleman, RE
机构
[1] Department of Radiology, Duke University, Medical Center, Durham
关键词
D O I
10.1109/23.552734
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Monte Carlo simulation was applied to model the penetration effect for iodine-131 pinhole imaging, In our Monte Carlo simulation, we employed the variance reduction technique, forced detection, to improve simulation efficiency. For the forced detection, the minimal cone that covers the knife-edge region of a pinhole aperture was used to confine the direction of a photon emission with the vertex located at the emission point. A lead pinhole insert was used to validate our Monte Carlo model, For the validation, the responses of a point source at six different locations along the central ray of the pinhole aperture were measured to compare with simulated responses, The range of distances for the source locations was 3-18 cm from the aperture with the inter-location distance equal to 3 cm, The comparison demonstrated the accuracy of our Monte Carlo model, With the validated Monte Carlo program, we simulated point response functions for pinhole aperture with various aperture span angle, hole size, and materials, The point responses were parameterized using radially circularly symmetric two-dimensional exponential functions, The parameter describing the roll-off rate of an exponential function was expressed in terms of the span angle of the pinhole knife-edge opening and the material used to make the pinhole aperture, The parameterized penetration model can be incorporated into image reconstruction algorithms that compensate for the penetration effect.
引用
收藏
页码:3272 / 3277
页数:6
相关论文
共 50 条
  • [1] Monte Carlo modeling of penetration effect for iodine-131 pinhole imaging
    Wang, HL
    Jaszczak, RJ
    Coleman, RE
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1558 - 1562
  • [2] Validation of a SIMIND Monte Carlo modelled gamma camera for Iodine-123 and Iodine-131 imaging
    Morphis, Michaella
    van Staden, Johan A.
    du Raan, Hanlie
    Ljungberg, Michael
    [J]. HELIYON, 2021, 7 (06)
  • [3] Evaluation of Iodine-123 and Iodine-131 SPECT activity quantification: a Monte Carlo study
    Michaella Morphis
    Johan A. van Staden
    Hanlie du Raan
    Michael Ljungberg
    [J]. EJNMMI Physics, 8
  • [4] Evaluation of Iodine-123 and Iodine-131 SPECT activity quantification: a Monte Carlo study
    Morphis, Michaella
    van Staden, Johan A.
    du Raan, Hanlie
    Ljungberg, Michael
    [J]. EJNMMI PHYSICS, 2021, 8 (01)
  • [5] Quantitative imaging of iodine-131 distributions in brain tumors with pinhole SPECT: A phantom study
    Smith, MF
    Gilland, DR
    Coleman, RE
    Jaszczak, RJ
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 856 - 864
  • [6] Evaluation of Acceptance Angle in Iodine-131 Single Photon Emission Computed Tomography Imaging with Monte Carlo Simulation
    Asmi, Hicham
    Bentayeb, Farida
    Bouzekraoui, Youssef
    Bonutti, Faustino
    [J]. INDIAN JOURNAL OF NUCLEAR MEDICINE, 2019, 34 (01): : 24 - 26
  • [7] Photon penetration and scatter in micro-pinhole imaging: a Monte Carlo investigation
    van der Have, F
    Beekman, FJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (08): : 1369 - 1386
  • [8] Monte Carlo evaluation of object shape effects in iodine-131 SPET tumor activity quantification
    Yuni K. Dewaraja
    Michael Ljungberg
    Kenneth F. Koral
    [J]. European Journal of Nuclear Medicine, 2001, 28 : 900 - 906
  • [9] SPECT imaging of Iodine-131 distribution in the head
    Gilland, DR
    Johnson, EL
    Turkington, TG
    Coleman, RE
    Jaszczak, RJ
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1092 - 1096
  • [10] Characterization of scatter and penetration using Monte Carlo simulation in 131I imaging
    Dewaraja, YK
    Ljungberg, M
    Koral, KF
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (01) : 123 - 130