Monte Carlo evaluation of object shape effects in iodine-131 SPET tumor activity quantification

被引:0
|
作者
Yuni K. Dewaraja
Michael Ljungberg
Kenneth F. Koral
机构
[1] Department of Radiology,
[2] Division of Nuclear Medicine,undefined
[3] The University of Michigan Medical Center,undefined
[4] 204 Zina Pitcher Place,undefined
[5] Ann Arbor,undefined
[6] MI 48109-0552,undefined
[7] USA,undefined
[8] Department of Radiation Physics,undefined
[9] University of Lund,undefined
[10] Lund,undefined
[11] Sweden,undefined
来源
关键词
Single-photon emission tomography Iodine-131 imaging Monte Carlo Partial volume effect Quantification;
D O I
暂无
中图分类号
学科分类号
摘要
In our clinical iodine-131 single-photon emission tomography (SPET) quantification for radioimmunotherapy, calibration and partial volume correction are based on measurements with phantoms containing spheres to simulate patient tumors even though real tumors are frequently nonspherical. In this study, Monte Carlo simulation was used to evaluate how object shape influences "spill-out" and "spill-in," which are major sources of quantification error associated with the poor spatial resolution of 131I SPET. Objects that varied in shape (spheres, cylinders, and an irregular structure) but were identical in activity and volume were simulated. Iterative reconstruction employed both attenuation and triple-energy-window scatter compensation. VOIs were defined in the reconstructed images both using physical boundaries and using expanded boundaries to allow for the limited resolution. When physical boundaries were used, both spill-out and spill-in were more significant for nonspherical structures than for spherical structures. Over the range of object volumes (50–200 ml) and at all background levels, VOI counts in cylinders were lower than VOI counts in spheres. This underestimation increased with decrease in object size (for the cold background –18% at 200 ml and –39% at 50 ml). It also decreased with increase in background activity because spill-in partially compensated for spill-out. It was shown that with a VOI larger than physical size, the results are independent of object shape and size only in the case of cold background. Activity quantification was carried out using a procedure similar to that used in our clinic. Quantification of nonspherical objects was improved by simple sphere-based partial volume correction, but the error was still large in some cases (for example, –39% for a 50-ml cylinder in a cold background and –35% for a 200-ml irregular structure defined on the basis of a typical tumor outlined on an X-ray computed tomography scan of a patient with non-Hodgkin's lymphoma). Partial volume correction by patient-specific Monte Carlo simulation may provide better quantification accuracy.
引用
收藏
页码:900 / 906
页数:6
相关论文
共 17 条
  • [1] Monte Carlo evaluation of object shape effects in iodine-1 31 SPET tumor activity quantification
    Dewaraja, YK
    Ljungberg, M
    Koral, KF
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (07) : 900 - 906
  • [2] Evaluation of Iodine-123 and Iodine-131 SPECT activity quantification: a Monte Carlo study
    Michaella Morphis
    Johan A. van Staden
    Hanlie du Raan
    Michael Ljungberg
    [J]. EJNMMI Physics, 8
  • [3] Evaluation of Iodine-123 and Iodine-131 SPECT activity quantification: a Monte Carlo study
    Morphis, Michaella
    van Staden, Johan A.
    du Raan, Hanlie
    Ljungberg, Michael
    [J]. EJNMMI PHYSICS, 2021, 8 (01)
  • [4] Monte Carlo modeling of penetration effect for iodine-131 pinhole imaging
    Wang, HL
    Jaszczak, RJ
    Coleman, RE
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1558 - 1562
  • [5] Monte carlo modeling of penetration effect for iodine-131 pinhole imaging
    Wang, HL
    Jaszczak, RJ
    Coleman, RE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) : 3272 - 3277
  • [6] Validation of a SIMIND Monte Carlo modelled gamma camera for Iodine-123 and Iodine-131 imaging
    Morphis, Michaella
    van Staden, Johan A.
    du Raan, Hanlie
    Ljungberg, Michael
    [J]. HELIYON, 2021, 7 (06)
  • [7] Evaluation of Acceptance Angle in Iodine-131 Single Photon Emission Computed Tomography Imaging with Monte Carlo Simulation
    Asmi, Hicham
    Bentayeb, Farida
    Bouzekraoui, Youssef
    Bonutti, Faustino
    [J]. INDIAN JOURNAL OF NUCLEAR MEDICINE, 2019, 34 (01): : 24 - 26
  • [8] Effect of object shape in SPECT quantification of 131I tumor activity.
    Dewaraja, YK
    Ljungberg, M
    Fessler, JA
    Koral, KF
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 104P - 104P
  • [9] CLIMATIC EFFECTS ON FRIESIANS AND BUFFALOES .3. THYROID GLAND ACTIVITY USING IODINE-131
    KAMAL, TH
    IBRAHIM, II
    [J]. JOURNAL OF DAIRY SCIENCE, 1968, 51 (06) : 970 - +
  • [10] BODY WEIGHT AND AGE EFFECTS ON FRIESIANS AND BUFFALOES .3. THYROID GLAND ACTIVITY USING IODINE-131
    KAMAL, TH
    IBRAHIM, II
    [J]. JOURNAL OF DAIRY SCIENCE, 1968, 51 (06) : 963 - +