摘要
Pinhole SPECT is rapidly gaining popularity for imaging laboratory animals using gamma-emitting molecules. Penetration and scattering of gamma radiation in the pinhole edge material can account for a significant fraction of the total number of photons detected, particularly if the pinholes have small diameters. This study characterizes the effects of penetration and scatter with micro-pinholes made of lead, tungsten, gold and platinum. Monte Carlo simulations are performed for I-125 (27-35 keV) and Tc-99m (140 keV) point sources with pinhole diameters ranging from 50 to 500 mum. The simulations account for the effects of photo-electric interaction, Rayleigh scattering, Compton scattering, ionization, bremsstrahlung and electron multiple scattering. As a typical example, in the case of a Tc-99m point source and pinholes with a diameter of 300 mum in gold or platinum, approximately 55% of the photons detected resulted from penetration and approximately 3% from scatter. For pinhole diameters ranging from 100 to 500 mum, the penetration fraction for tungsten and lead was approx a factor of 1.0 to 1.6 higher and the scatter fraction was 1.0 to 1.8 times higher than in case of gold or platinum. Using I-125 instead of Tc-99m decreases the penetration fraction by a factor ranging from 3 to 11 and the scatter fraction by a factor ranging from 12 to 40. For all materials studied, the total amounts of penetrated and scattered photons changed approximately linearly with respect to the pinhole diameter.
引用
收藏
页码:1369 / 1386
页数:18
相关论文
共 50 条
  • [1] Fast simulation of micro-pinhole imaging by mixing Monte Carlo and analytical modeling
    Gieles, M
    de Jong, HWAM
    Beekman, FJ
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1830 - 1834
  • [2] Penetration, scatter and sensitivity in channel micro-pinholes for SPECT: A Monte Carlo investigation
    van der Have, Frans
    Beekman, Freek J.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2635 - 2645
  • [3] Penetration and scatter in channel micropinholes for SPECT: a Monte Carlo investigation
    van der Have, F
    Beekman, FJ
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2575 - 2578
  • [4] Monte carlo modeling of penetration effect for iodine-131 pinhole imaging
    Wang, HL
    Jaszczak, RJ
    Coleman, RE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) : 3272 - 3277
  • [5] Monte Carlo modeling of penetration effect for iodine-131 pinhole imaging
    Wang, HL
    Jaszczak, RJ
    Coleman, RE
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1558 - 1562
  • [6] Characterization of scatter and penetration using Monte Carlo simulation in 131I imaging
    Dewaraja, YK
    Ljungberg, M
    Koral, KF
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (01) : 123 - 130
  • [7] Investigation of the scatter contribution in single photon transmission measurements by means of Monte Carlo simulations
    Wegmann, K
    Adam, LE
    Livieratos, L
    Zaers, J
    Bailey, DL
    Brix, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 1184 - 1190
  • [8] Coherent scatter imaging Monte Carlo simulation
    Hassan, Laila
    MacDonald, Carolyn A.
    [J]. JOURNAL OF MEDICAL IMAGING, 2016, 3 (03)
  • [9] MONTE-CARLO SIMULATION OF PHOTON DETECTION FOR SPECT PINHOLE COLLIMATION
    WANG, H
    JASZCZAK, RJ
    COLEMAN, RE
    [J]. RADIOLOGY, 1992, 185 : 176 - 176
  • [10] SCATTER CORRECTION FOR TL-201 CARDIAC IMAGING - A MONTE-CARLO INVESTIGATION
    DEVRIES, DJ
    KING, MA
    WEINSTEIN, H
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P192 - P192