Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults

被引:98
|
作者
Desai, Gaurav S. [2 ]
Uppot, Raul N. [2 ]
Yu, Elaine W. [3 ]
Kambadakone, Avinash R. [2 ]
Sahani, Dushyant V. [1 ,2 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Div Abdominal Imaging & Intervent,Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Abdominal Imaging & Intervent, Boston, MA 02114 USA
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Endocrine Unit, Boston, MA 02114 USA
关键词
Iterative reconstruction; Computed tomography; Image quality; Radiation dose; Obesity; TUBE CURRENT MODULATION; ABDOMINAL CT; COMPUTED-TOMOGRAPHY; PATIENT SIZE; REDUCTION; EXPOSURE; OBESITY; ALGORITHM; MDCT; OPTIMIZATION;
D O I
10.1007/s00330-012-2424-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare image quality and radiation dose using Adaptive Statistical Iterative Reconstruction (ASiR) and Filtered Back Projection (FBP) in patients weighing a parts per thousand yen91 kg. In this Institution Review Board-approved retrospective study, single-phase contrast-enhanced abdominopelvic CT examinations of 100 adults weighing a parts per thousand yen91 kg (mean body weight: 107.6 +/- 17.4 kg range: 91-181.9 kg) with (1) ASiR and (2) FBP were reviewed by two readers in a blinded fashion for subjective measures of image quality (using a subjective standardized numerical scale and objective noise) and for radiation exposure. Imaging parameters and radiation dose results of the two techniques were compared within weight and BMI sub-categories. All examinations were found to be of adequate quality. Both subjective (mean = 1.4 +/- 0.5 vs. 1.6 +/- 0.6, P < 0.05) and objective noise (13.0 +/- 3.2 vs.19.5 +/- 5.7, P < 0.0001) were lower with ASiR. Average radiation dose reduction of 31.5 % was achieved using ASiR (mean CTDIvol. ASiR: 13.5 +/- 7.3 mGy; FBP: 19.7 +/- 9.0 mGy, P < 0.0001). Other measures of image quality were comparable between the two techniques. Trends for all parameters were similar in patients across weight and BMI sub-categories. In obese individuals, abdominal CT images reconstructed using ASiR provide diagnostic images with reduced image noise at lower radiation dose. aEuro cent CT images in obese adults are noisy, even with high radiation dose. aEuro cent Newer iterative reconstruction techniques have theoretical advantages in obese patients. aEuro cent Adaptive statistical iterative reconstruction should reduce image noise and radiation dose. aEuro cent This has been proven in abdominopelvic CT images of obese patients.
引用
收藏
页码:1631 / 1640
页数:10
相关论文
共 50 条
  • [1] Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults
    Gaurav S. Desai
    Raul N. Uppot
    Elaine W. Yu
    Avinash R. Kambadakone
    Dushyant V. Sahani
    European Radiology, 2012, 22 : 1631 - 1640
  • [2] The impact of iterative reconstruction on image quality and radiation dose in thoracic and abdominal CT
    Kalmar, Peter I.
    Quehenberger, Franz
    Steiner, Juergen
    Lutfi, Andre
    Bohlsen, Dennis
    Talakic, Emina
    Hassler, Eva Maria
    Schoellnast, Helmut
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (08) : 1416 - 1420
  • [3] Iterative Reconstruction for Head CT: Effects on Radiation Dose and Image Quality
    Rivers-Bowerman, Michael D.
    Shankar, Jai Jai Shiva
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2014, 41 (05) : 620 - 625
  • [4] Impact of the Adaptive Statistical Iterative Reconstruction Technique on Radiation Dose and Image Quality in Bone SPECT/CT
    Sibille, Louis
    Chambert, Benjamin
    Alonso, Sandrine
    Barrau, Corinne
    D'Estanque, Emmanuel
    Al Tabaa, Yassine
    Collombier, Laurent
    Demattei, Christophe
    Kotzki, Pierre-Olivier
    Boudousq, Vincent
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (07) : 1091 - 1095
  • [5] Model-based Iterative Reconstruction: Effect on Patient Radiation Dose and Image Quality in Pediatric Body CT
    Smith, Ethan A.
    Dillman, Jonathan R.
    Goodsitt, Mitchell M.
    Christodoulou, Emmanuel G.
    Keshavarzi, Nahid
    Strouse, Peter J.
    RADIOLOGY, 2014, 270 (02) : 526 - 534
  • [6] Multidetector CT of bronchiectasis: Effect of radiation dose on image quality
    Yi, CA
    Lee, KS
    Kim, TS
    Han, DH
    Sung, YM
    Kim, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (02) : 501 - 505
  • [7] Impact of iterative reconstruction on image quality of low-dose CT of the lumbar spine
    Alshamari, Muhammed
    Geijer, Mats
    Norrman, Eva
    Liden, Mats
    Krauss, Wolfgang
    Jendeberg, Johan
    Magnuson, Anders
    Geijer, Hakan
    ACTA RADIOLOGICA, 2017, 58 (06) : 702 - 709
  • [8] Iterative Reconstruction Algorithm for Abdominal Multidetector CT at Different Tube Voltages: Assessment of Diagnostic Accuracy, Image Quality, and Radiation Dose in a Phantom Study
    Schindera, Sebastian T.
    Diedrichsen, Lars
    Mueller, Hubert C.
    Rusch, Oliver
    Marin, Daniele
    Schmidt, Bernhard
    Raupach, Rainer
    Vock, Peter
    Szucs-Farkas, Zsolt
    RADIOLOGY, 2011, 260 (02) : 454 - 462
  • [9] The influence of iterative reconstruction level on image quality and radiation dose in CT pulmonary angiography examinations
    Harun, H.H.
    Karim, M.K.A.
    Abbas, Z.
    Sabarudin, A.
    Muniandy, S.C.
    Razak, H.R.A.
    Ng, K.H.
    Radiation Physics and Chemistry, 2021, 178
  • [10] The influence of iterative reconstruction level on image quality and radiation dose in CT pulmonary angiography examinations
    Harun, H. H.
    Karim, M. K. A.
    Abbas, Z.
    Sabarudin, A.
    Muniandy, S. C.
    Razak, H. R. A.
    Ng, K. H.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 178