Heart beat detection using a multimodal data coupling method

被引:18
|
作者
Mollakazemi, M. Javad [1 ]
Atyabi, S. Abbas [1 ]
Ghaffari, Ali [1 ]
机构
[1] KN Toosi Univ Technol, Dept Mech Engn, CVRG, Tehran, Iran
关键词
heart beat detection; multimodal data; ECG; blood pressure; pulsatile signals; ALGORITHM; SIGNALS;
D O I
10.1088/0967-3334/36/8/1729
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The most straightforward method for heart beat estimation is R-peak detection based on an electrocardiogram (ECG) signal. Current R-peak detection methods do not work properly when the ECG signal is contaminated or missing, which leads to the incorrect estimation of the heart rate. This raises the need for reliable algorithms which can locate heart beats in continuous long-term multimodal data, allowing robust analysis. In this paper, three peak detectors are evaluated for heart beat detection using various cardiovascular signals. One of the peak detectors is a new general peak detector (GPD) algorithm which is applicable on ECG and other pulsatile signals to compensate for the limitation of QRS detection. This peak detector algorithm is adaptive and independently finds amplitude characteristics for every recording, while not tuned for ECG or other pulsatile signals. Three strategies, which are different disciplines of detectors, are then proposed while the fusion method remains the same in all strategies. In the first strategy, the ECG and the lowest-indexed signal of general blood pressure (BP), arterial blood pressure (ART) and pulmonary arterial pressure (PAP) are processed through gqrs and wabp (from the PhysioNet library), respectively. In the second strategy, all beats in different signals are detected by GPD. In the third strategy, ECG and other signals are processed by gqrs and GPD, respectively. In all three strategies two criteria are used in order to fuse the detections. The first criterion is based on the number of candidate detections in a specific time period, based on which signals of interest are selected. The second fusion criterion is based on the regularity of the derived intervals between subsequent candidate detections. If the number of detections in ECG and one of BP, ART and PAP signals have reasonable physiological range, a new signal is generated in which they are coupled with each other. Heart beats can more easily be detected in noisy parts of these signals using the new coupled waveform. For instance, if ECG and BP are coupled, BP pulses make the real heart beats in noisy parts of ECG detectable and ECG R-peaks make the weak BP pulses detectable in the new waveform. The proposed peak detector is developed using the MIT/BIH arrhythmia database. Furthermore, heart beat detection strategies were evaluated using the train and test datasets of PhysioNet/CinC Challenge (2014), and the overall results of the strategies are compared.
引用
收藏
页码:1729 / 1742
页数:14
相关论文
共 50 条
  • [1] Heart Beat Detection in Multimodal Data Using Signal Recognition and Beat Location Estimation
    De Cooman, Thomas
    Goovaerts, Griet
    Varon, Carolina
    Widjaja, Devy
    Van Huffel, Sabine
    [J]. 2014 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 41, 2014, 41 : 257 - 260
  • [2] Heart beat detection in multimodal data using automatic relevant signal detection
    De Cooman, Thomas
    Goovaerts, Griet
    Varon, Carolina
    Widjaja, Devy
    Willemen, Tim
    Van Huffel, Sabine
    [J]. PHYSIOLOGICAL MEASUREMENT, 2015, 36 (08) : 1691 - 1704
  • [3] Multimodal heart beat detection using signal quality indices
    Johnson, Alistair E. W.
    Behar, Joachim
    Andreotti, Fernando
    Clifford, Gari D.
    Oster, Julien
    [J]. PHYSIOLOGICAL MEASUREMENT, 2015, 36 (08) : 1665 - 1677
  • [4] Detection of heart beats in multimodal data: a robust beat-to-beat interval estimation approach
    Antink, Christoph Hoog
    Brueser, Christoph
    Leonhardt, Steffen
    [J]. PHYSIOLOGICAL MEASUREMENT, 2015, 36 (08) : 1679 - 1690
  • [5] Probabilistic data fusion model for heart beat detection from multimodal physiological data
    Zia, Tehseen
    Arif, Zulqarnian
    [J]. TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2017, 25 (01) : 449 - 460
  • [6] Multimodal Information Fusion for Robust Heart Beat Detection
    Ding, Quan
    Bai, Yong
    Erol, Yusuf Bugra
    Salas-Boni, Rebeca
    Zhang, Xiaorong
    Li, Lei
    Hu, Xiao
    [J]. 2014 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 41, 2014, 41 : 261 - 264
  • [7] Heart beat detection in multimodal physiological data using a hidden semi-Markov model and signal quality indices
    Pimentel, Marco A. F.
    Santos, Mauro D.
    Springer, David B.
    Clifford, Gari D.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2015, 36 (08) : 1717 - 1727
  • [8] Beat-to-beat heart rate estimation fusing multimodal video and sensor data
    Antink, Christoph Hoog
    Gao, Hanno
    Brueser, Christoph
    Leonhardt, Steffen
    [J]. BIOMEDICAL OPTICS EXPRESS, 2015, 6 (08): : 2895 - 2907
  • [9] Assessment of beat-to-beat heart rate detection method using a camera as contactless sensor
    Iozzia, L.
    Cerina, L.
    Mainardi, L. T.
    [J]. 2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 521 - 524
  • [10] Identification of a signal for an optimal heart beat detection in multimodal physiological datasets
    Schulte, Roman
    Krug, Johannes
    Rose, Georg
    [J]. 2014 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 41, 2014, 41 : 273 - 276