Heart beat detection using a multimodal data coupling method

被引:18
|
作者
Mollakazemi, M. Javad [1 ]
Atyabi, S. Abbas [1 ]
Ghaffari, Ali [1 ]
机构
[1] KN Toosi Univ Technol, Dept Mech Engn, CVRG, Tehran, Iran
关键词
heart beat detection; multimodal data; ECG; blood pressure; pulsatile signals; ALGORITHM; SIGNALS;
D O I
10.1088/0967-3334/36/8/1729
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The most straightforward method for heart beat estimation is R-peak detection based on an electrocardiogram (ECG) signal. Current R-peak detection methods do not work properly when the ECG signal is contaminated or missing, which leads to the incorrect estimation of the heart rate. This raises the need for reliable algorithms which can locate heart beats in continuous long-term multimodal data, allowing robust analysis. In this paper, three peak detectors are evaluated for heart beat detection using various cardiovascular signals. One of the peak detectors is a new general peak detector (GPD) algorithm which is applicable on ECG and other pulsatile signals to compensate for the limitation of QRS detection. This peak detector algorithm is adaptive and independently finds amplitude characteristics for every recording, while not tuned for ECG or other pulsatile signals. Three strategies, which are different disciplines of detectors, are then proposed while the fusion method remains the same in all strategies. In the first strategy, the ECG and the lowest-indexed signal of general blood pressure (BP), arterial blood pressure (ART) and pulmonary arterial pressure (PAP) are processed through gqrs and wabp (from the PhysioNet library), respectively. In the second strategy, all beats in different signals are detected by GPD. In the third strategy, ECG and other signals are processed by gqrs and GPD, respectively. In all three strategies two criteria are used in order to fuse the detections. The first criterion is based on the number of candidate detections in a specific time period, based on which signals of interest are selected. The second fusion criterion is based on the regularity of the derived intervals between subsequent candidate detections. If the number of detections in ECG and one of BP, ART and PAP signals have reasonable physiological range, a new signal is generated in which they are coupled with each other. Heart beats can more easily be detected in noisy parts of these signals using the new coupled waveform. For instance, if ECG and BP are coupled, BP pulses make the real heart beats in noisy parts of ECG detectable and ECG R-peaks make the weak BP pulses detectable in the new waveform. The proposed peak detector is developed using the MIT/BIH arrhythmia database. Furthermore, heart beat detection strategies were evaluated using the train and test datasets of PhysioNet/CinC Challenge (2014), and the overall results of the strategies are compared.
引用
收藏
页码:1729 / 1742
页数:14
相关论文
共 50 条
  • [31] A Novel Method to Detect Heart Beat Rate Using a Mobile Phone
    Pelegris, P.
    Banitsas, K.
    Orbach, T.
    Marias, K.
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 5488 - 5491
  • [32] New Method for Beat-to-Beat Fetal Heart Rate Measurement Using Doppler Ultrasound Signal
    Kupka, Tomasz
    Matonia, Adam
    Jezewski, Michal
    Jezewski, Janusz
    Horoba, Krzysztof
    Wrobel, Janusz
    Czabanski, Robert
    Martinek, Radek
    [J]. SENSORS, 2020, 20 (15) : 1 - 25
  • [33] Design and simulation of a life detection system based on detection of the heart beat using Doppler frequency
    Izadi, A.
    Ghatan, Z.
    Vahdat, B. Vosoughi
    Farzaneh, F.
    [J]. 2006 IEEE International Symposium on Signal Processing and Information Technology, Vols 1 and 2, 2006, : 685 - 690
  • [34] Robust heart rate estimation from multimodal physiological signals using beat signal quality index based majority voting fusion method
    Rankawat, Shalini A.
    Dubey, Rahul
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2017, 33 : 201 - 212
  • [35] A Tutorial Review on Data Compression with Detection of Fetal Heart Beat from Noisy ECG
    Reddy, Bommepalli Madhava
    Subbareddy, Thadigotla Venkata
    Reddy, Saureddy Omkar
    Elamaran, V.
    [J]. 2014 INTERNATIONAL CONFERENCE ON CONTROL, INSTRUMENTATION, COMMUNICATION AND COMPUTATIONAL TECHNOLOGIES (ICCICCT), 2014, : 1310 - 1314
  • [36] PVC DETECTION BY HEART-BEAT INTERVAL DATA - MARKOV-CHAIN APPROACH
    GERSCH, W
    LILLY, P
    DONG, E
    [J]. COMPUTERS AND BIOMEDICAL RESEARCH, 1975, 8 (04): : 370 - 378
  • [37] A VLSI Chip for the Abnormal Heart Beat Detection Using Convolutional Neural Network
    Chen, Yuan-Ho
    Chen, Szi-Wen
    Chang, Pei-Jung
    Hua, Hsin-Tung
    Lin, Shinn-Yn
    Chen, Rou-Shayn
    [J]. SENSORS, 2022, 22 (03)
  • [38] A HEART BEAT RATE DETECTION FRAMEWORK USING MULTIPLE NANOFIBER SENSOR SIGNALS
    Zou, Liang
    Chen, Xun
    Servati, Amir
    Servati, Peyman
    McKeown, Martin J.
    [J]. 2014 IEEE CHINA SUMMIT & INTERNATIONAL CONFERENCE ON SIGNAL AND INFORMATION PROCESSING (CHINASIP), 2014, : 242 - 246
  • [39] Accurate Heart Beat Detection with Doppler Radar using Bidirectional GRU Network
    Lu, Hui
    Heyder, Markus
    Wenzel, Marvin
    Albrecht, Nils C.
    Langer, Dominik
    Koelpin, Alexander
    [J]. 2023 IEEE RADIO AND WIRELESS SYMPOSIUM, RWS, 2023, : 52 - 54
  • [40] A new method of using heart rate to represent energy expenditure: The Total Heart Beat Index
    Hood, VL
    Granat, MH
    Maxwell, DJ
    Hasler, JP
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (09): : 1266 - 1273