Heart beat detection using a multimodal data coupling method

被引:18
|
作者
Mollakazemi, M. Javad [1 ]
Atyabi, S. Abbas [1 ]
Ghaffari, Ali [1 ]
机构
[1] KN Toosi Univ Technol, Dept Mech Engn, CVRG, Tehran, Iran
关键词
heart beat detection; multimodal data; ECG; blood pressure; pulsatile signals; ALGORITHM; SIGNALS;
D O I
10.1088/0967-3334/36/8/1729
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The most straightforward method for heart beat estimation is R-peak detection based on an electrocardiogram (ECG) signal. Current R-peak detection methods do not work properly when the ECG signal is contaminated or missing, which leads to the incorrect estimation of the heart rate. This raises the need for reliable algorithms which can locate heart beats in continuous long-term multimodal data, allowing robust analysis. In this paper, three peak detectors are evaluated for heart beat detection using various cardiovascular signals. One of the peak detectors is a new general peak detector (GPD) algorithm which is applicable on ECG and other pulsatile signals to compensate for the limitation of QRS detection. This peak detector algorithm is adaptive and independently finds amplitude characteristics for every recording, while not tuned for ECG or other pulsatile signals. Three strategies, which are different disciplines of detectors, are then proposed while the fusion method remains the same in all strategies. In the first strategy, the ECG and the lowest-indexed signal of general blood pressure (BP), arterial blood pressure (ART) and pulmonary arterial pressure (PAP) are processed through gqrs and wabp (from the PhysioNet library), respectively. In the second strategy, all beats in different signals are detected by GPD. In the third strategy, ECG and other signals are processed by gqrs and GPD, respectively. In all three strategies two criteria are used in order to fuse the detections. The first criterion is based on the number of candidate detections in a specific time period, based on which signals of interest are selected. The second fusion criterion is based on the regularity of the derived intervals between subsequent candidate detections. If the number of detections in ECG and one of BP, ART and PAP signals have reasonable physiological range, a new signal is generated in which they are coupled with each other. Heart beats can more easily be detected in noisy parts of these signals using the new coupled waveform. For instance, if ECG and BP are coupled, BP pulses make the real heart beats in noisy parts of ECG detectable and ECG R-peaks make the weak BP pulses detectable in the new waveform. The proposed peak detector is developed using the MIT/BIH arrhythmia database. Furthermore, heart beat detection strategies were evaluated using the train and test datasets of PhysioNet/CinC Challenge (2014), and the overall results of the strategies are compared.
引用
收藏
页码:1729 / 1742
页数:14
相关论文
共 50 条
  • [21] COUPLING BETWEEN PECKING AND HEART BEAT IN PIGEONS
    DELIUS, JD
    LINDENBLATT, U
    LOMBARDI, C
    JOURNAL OF INTERDISCIPLINARY CYCLE RESEARCH, 1986, 17 (04): : 243 - 251
  • [22] Beat-to-beat heart rate detection by smartphone accelerometers
    Landreani, F.
    Martin-Yebra, A.
    Casellato, C.
    Frigo, C.
    Pavan, E.
    Migeotte, P. -F.
    Caiani, E. G.
    EUROPEAN HEART JOURNAL, 2016, 37 : 859 - 860
  • [23] Deepfake source detection in a heart beat
    Umur Aybars Çiftçi
    İlke Demir
    Lijun Yin
    The Visual Computer, 2024, 40 : 2733 - 2750
  • [24] Deepfake source detection in a heart beat
    Ciftci, Umur Aybars
    Demir, Ilke
    Yin, Lijun
    VISUAL COMPUTER, 2024, 40 (04): : 2733 - 2750
  • [25] Atrial fibrillation detection using Poincare geometry and heart beat intervals
    Rao, S. K. Shrikanth
    Kolekar, Maheshkumar H.
    Martis, Roshan Joy
    EXPERT SYSTEMS, 2023, 40 (07)
  • [26] An online PPGI approach for camera based heart rate monitoring using beat-to-beat detection
    Bloecher, Timon
    Schneider, Johannes
    Schinle, Markus
    Stork, Wilhelm
    2017 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS), 2017,
  • [27] ECG Heart beat detection using modified Slope Sum Function and Teager-Kaiser Energy method
    Rankawat, Shalini A.
    2018 2ND INTERNATIONAL CONFERENCE ON BIOSIGNAL ANALYSIS, PROCESSING AND SYSTEMS (ICBAPS 2018), 2018, : 59 - 64
  • [28] ECG Data Compression using Adaptive Beat Subtraction Method
    Pathoumvanh, Somsanouk
    Airphaiboon, Surapan
    Hamamoto, Kazuhiko
    2008 INTERNATIONAL SYMPOSIUM ON COMMUNICATIONS AND INFORMATION TECHNOLOGIES, 2008, : 477 - +
  • [29] A Novel Approach for Robust Detection of Heart Beats in Multimodal Data using Neural Networks and Boosted Trees
    Vernekar, Sachin
    Vijaysenani, Deepu
    Ranjan, Rohit
    2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 1137 - 1140
  • [30] Student Attention Detection Using Multimodal Data Fusion
    Mallibhat, Kaushik
    2024 IEEE INTERNATIONAL CONFERENCE ON ADVANCED LEARNING TECHNOLOGIES, ICALT 2024, 2024, : 295 - 297