Histopathological comparison of biodegradable polymer and permanent polymer based sirolimus eluting stents in a porcine model of coronary stent implantation

被引:46
|
作者
Koppara, Tobias [1 ]
Joner, Michael [1 ]
Bayer, Gerd [2 ]
Steigerwald, Kristin [1 ]
Diener, Tobias [2 ]
Wittchow, Eric [2 ]
机构
[1] Deutsch Herzzentrum Munich, D-80636 Munich, Germany
[2] BIOTRONIK SE & Co KG, Erlangen, Germany
关键词
Porcine model; sirolimus-eluting stents; restenosis; POOLED ANALYSIS; DURABLE POLYMER; CLINICAL-OUTCOMES; RELEASE PROFILES; COATED STENTS; FOLLOW-UP; IN-VITRO; DRUG; RESTENOSIS; TRIAL;
D O I
10.1160/TH12-01-0043
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Biodegradable stent coatings were recently introduced as a potential solution to overcome sustained inflammatory responses observed with permanent polymer-based drug-eluting stents. In a preliminary study, selected biodegradable or permanent polymer-based sirolimus-eluting stent (SES) formulations were screened for effectiveness in comparison to bare metal stents (BMS) at 28 days. Subsequently, the most favourable SES formulation was compared to commercially available SES (Cypher (TM)) at 28,90 and 180 days to investigate the histopathologic response as well as tissue, blood and organ pharmacokinetics. Overlapping SES implantation was conducted to evaluate vascular healing at 28 days in this particular setting. SES with biodegradable poly (L-lactide) polymer (PLLA) or poly(lactide-co-glycolide) showed the most favourable outcome with regards to reductions in neointimal area in comparison to BMS at 28 days. The PLLA SES showed a similar reduction in neointimal area compared to Cypher (TM) at 28 days, with significant greater reductions at 90 and 180 days (1.7 +/- 0.7 mm(2) vs. 3.1 +/- 1.5 mm(2), p=0.03 and 1.8 +/- 1.2 mm(2) vs. 3.0 +/- 1.5 mm(2), p=0.01, respectively). Sirolimus vascular tissue concentrations were detectable up to 90 days following implantation. Overlapping stented segments showed favourable histopathologic results with respect to fibrin deposition and endothelialisation at 28 days. In conclusion, the use of PLLA as drug-eluting matrix resulted in mild inflammatory responses in the presence of effective sirolimus tissue concentrations. The greater efficacy observed at long-term follow-up in PLLA SES compared to Cypher (TM) may be a multifactorial result of stent design, polymer biocompatibility and improved release kinetics.
引用
收藏
页码:1161 / 1171
页数:11
相关论文
共 50 条
  • [41] ENDOTHELIAL MATURATION AND FUNCTION FOLLOWING IMPLANTATION OF ABLUMINAL COATING BIODEGRADABLE POLYMER BASED SIROLIMUS-ELUTING METALLIC STENT VERSUS CONFORMAL COATING DURABLE POLYMER BASED EVEROLIMUS ELUTING STENT
    Mori, Hiroyoshi
    Cheng, Qi
    Lutter, Christoph
    Acampado, Eduardo
    Guo, Liang
    Kutyna, Matthew
    Torii, Sho
    Harari, Emanuel
    Virmani, Renu
    Finn, Aloke
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1066 - 1066
  • [42] BIODEGRADABLE POLYMER SIROLIMUS ELUTING STENT (ORSIRO) VERSUS SECOND GENERATION DURABLE POLYMER DRUG ELUTING STENTS: A META-ANALYSIS OF RANDOMISED TRIALS
    Monjur, Mohammad R.
    Said, Christian F.
    Bamford, Paul
    Parkinson, Michael
    Szirt, Richard
    Ford, Thomas J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1331 - 1331
  • [43] First-in-man randomised comparison of the BuMA Supreme biodegradable polymer sirolimus-eluting stent versus a durable polymer zotarolimus-eluting coronary stent: the PIONEER trial
    von Birgelen, Clemens
    Asano, Taku
    Amoroso, Giovanni
    Aminian, Adel
    Brugaletta, Salvatore
    Vrolix, Mathias
    Hernandez-Antolin, Rosana
    van de Harst, Pim
    Iniguez, Andres
    Janssens, Luc
    Smits, Pieter C.
    Wykrzykowska, Joanna J.
    Ribeiro, Vasco Gama
    Pereira, Helder
    da Silva, Pedro Canas
    Piek, Jan J.
    Onuma, Yoshinobu
    Serruys, Patrick W.
    Sabate, Manel
    EUROINTERVENTION, 2018, 13 (17) : 2026 - 2035
  • [44] Clinical outcome of biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with diabetes
    Kakizaki, Ryota
    Minami, Yoshiyasu
    Katamine, Masahiro
    Katsura, Aritomo
    Muramatsu, Yusuke
    Hashimoto, Takuya
    Meguro, Kentaro
    Shimohama, Takao
    Ako, Junya
    CARDIOVASCULAR DIABETOLOGY, 2020, 19 (01)
  • [45] Angioscopic Assessment of Arterial Repair Following Biodegradable Polymer-Coated Biolimus A9-Eluting Stent Implantation - Comparison With Durable Polymer-Coated Sirolimus-Eluting Stent
    Awata, Masaki
    Uematsu, Masaaki
    Sera, Fusako
    Ishihara, Takayuki
    Watanabe, Tetsuya
    Fujita, Masashi
    Onishi, Toshinari
    Iida, Osamu
    Ishida, Yoshio
    Nanto, Shinsuke
    Nagata, Seiki
    CIRCULATION JOURNAL, 2011, 75 (05) : 1113 - 1119
  • [46] Evaluation of a tapered polymer-free sirolimus-eluting stent in porcine coronary arteries
    Shi, Qiu-Ping
    Zheng, Bo
    Chen, Ming
    Wang, Xin-Gang
    Zhang, Bin
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (03): : 5379 - 5388
  • [47] Clinical outcome of biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with diabetes
    Ryota Kakizaki
    Yoshiyasu Minami
    Masahiro Katamine
    Aritomo Katsura
    Yusuke Muramatsu
    Takuya Hashimoto
    Kentaro Meguro
    Takao Shimohama
    Junya Ako
    Cardiovascular Diabetology, 19
  • [48] Long-term vascular response to biodegradable polymer biolimus-eluting stents in comparison with durable polymer sirolimus-eluting stents and bare-metal stents
    Kuramitsu, S.
    Sonoda, S.
    Yokoi, H.
    Iwabuchi, M.
    Domei, T.
    Shirai, S.
    Ando, K.
    Nobuyoshi, M.
    EUROPEAN HEART JOURNAL, 2014, 35 : 1142 - 1142
  • [49] Comparisons of early vascular reaction between 2 biodegradable polymer and durable polymer based drug eluting stents in porcine coronary artery
    Ijichi, T.
    Nakazawa, G.
    Sho, S.
    Nagamatsu, H.
    Ayako, Y.
    Nakamura, S.
    Souba, J.
    Hagiwara, H.
    Ikari, Y.
    EUROPEAN HEART JOURNAL, 2016, 37 : 668 - 669
  • [50] Long-term effects of polymer-based, slow-release, sirolimus-eluting stents in a porcine coronary model
    Carter, AJ
    Aggarwal, M
    Kopia, GA
    Tio, F
    Tsao, PS
    Kolata, R
    Yeung, AC
    Llanos, G
    Dooley, L
    Falotico, R
    CARDIOVASCULAR RESEARCH, 2004, 63 (04) : 617 - 624