Histopathological comparison of biodegradable polymer and permanent polymer based sirolimus eluting stents in a porcine model of coronary stent implantation

被引:46
|
作者
Koppara, Tobias [1 ]
Joner, Michael [1 ]
Bayer, Gerd [2 ]
Steigerwald, Kristin [1 ]
Diener, Tobias [2 ]
Wittchow, Eric [2 ]
机构
[1] Deutsch Herzzentrum Munich, D-80636 Munich, Germany
[2] BIOTRONIK SE & Co KG, Erlangen, Germany
关键词
Porcine model; sirolimus-eluting stents; restenosis; POOLED ANALYSIS; DURABLE POLYMER; CLINICAL-OUTCOMES; RELEASE PROFILES; COATED STENTS; FOLLOW-UP; IN-VITRO; DRUG; RESTENOSIS; TRIAL;
D O I
10.1160/TH12-01-0043
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Biodegradable stent coatings were recently introduced as a potential solution to overcome sustained inflammatory responses observed with permanent polymer-based drug-eluting stents. In a preliminary study, selected biodegradable or permanent polymer-based sirolimus-eluting stent (SES) formulations were screened for effectiveness in comparison to bare metal stents (BMS) at 28 days. Subsequently, the most favourable SES formulation was compared to commercially available SES (Cypher (TM)) at 28,90 and 180 days to investigate the histopathologic response as well as tissue, blood and organ pharmacokinetics. Overlapping SES implantation was conducted to evaluate vascular healing at 28 days in this particular setting. SES with biodegradable poly (L-lactide) polymer (PLLA) or poly(lactide-co-glycolide) showed the most favourable outcome with regards to reductions in neointimal area in comparison to BMS at 28 days. The PLLA SES showed a similar reduction in neointimal area compared to Cypher (TM) at 28 days, with significant greater reductions at 90 and 180 days (1.7 +/- 0.7 mm(2) vs. 3.1 +/- 1.5 mm(2), p=0.03 and 1.8 +/- 1.2 mm(2) vs. 3.0 +/- 1.5 mm(2), p=0.01, respectively). Sirolimus vascular tissue concentrations were detectable up to 90 days following implantation. Overlapping stented segments showed favourable histopathologic results with respect to fibrin deposition and endothelialisation at 28 days. In conclusion, the use of PLLA as drug-eluting matrix resulted in mild inflammatory responses in the presence of effective sirolimus tissue concentrations. The greater efficacy observed at long-term follow-up in PLLA SES compared to Cypher (TM) may be a multifactorial result of stent design, polymer biocompatibility and improved release kinetics.
引用
收藏
页码:1161 / 1171
页数:11
相关论文
共 50 条
  • [31] Comparison of Sirolimus Eluting Stent With Bioresorbable Polymer to Everolimus Eluting Stent With Permanent Polymer in Bifurcation Lesions: Results From CENTURY II Trial
    Orvin, K.
    Carrie, D.
    Richardt, G.
    Desmet, W.
    Assali, A.
    Werner, G.
    Ikari, Y.
    Fujii, K.
    Goicolea, J.
    Dangoisse, V.
    Manari, A.
    Saito, S.
    Wijns, W.
    Kornowski, R.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 87 (06) : 1092 - 1100
  • [32] Unselected Use of Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Coronary Revascularization
    Yamaji, Kyohei
    Zanchin, Thomas
    Zanchin, Christian
    Stortecky, Stefan
    Koskinas, Konstantinos C.
    Hunziker, Lukas
    Praz, Fabien
    Bloechlinger, Stefan
    Moro, Christina
    Moschovitis, Aris
    Seiler, Christian
    Valgimigli, Marco
    Billinger, Michael
    Pilgrim, Thomas
    Heg, Dik
    Windecker, Stephan
    Raeber, Lorenz
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (09)
  • [33] Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention The SORT OUT VII Trial
    Jensen, Lisette Okkels
    Thayssen, Per
    Maeng, Michael
    Ravkilde, Jan
    Krusell, Lars Romer
    Raungaard, Bent
    Junker, Anders
    Terkelsen, Christian Juhl
    Veien, Karsten Tange
    Villadsen, Anton Boel
    Kaltoft, Anne
    Tilsted, Hans-Henrik
    Hansen, Knud Norregaard
    Aaroe, Jens
    Kristensen, Steen Dalby
    Hansen, Henrik Steen
    Jensen, Svend Eggert
    Madsen, Morten
    Botker, Hans Erik
    Berencsi, Klara
    Lassen, Jens Flensted
    Christiansen, Evald Hoj
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (07)
  • [34] Case series of coronary artery aneurysms after Everolimus eluting stent implantation and comparison with Sirolimus eluting stents
    Raghav Sharma
    Aditya Vikram Ruia
    Tek Singh Mahant
    BMC Cardiovascular Disorders, 22
  • [35] Case series of coronary artery aneurysms after Everolimus eluting stent implantation and comparison with Sirolimus eluting stents
    Sharma, Raghav
    Ruia, Aditya Vikram
    Mahant, Tek Singh
    BMC CARDIOVASCULAR DISORDERS, 2022, 22 (01)
  • [36] Biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for primary percutaneous coronary revascularisation of acute myocardial infarction
    Pilgrim, Thomas
    Piccolo, Raffaele
    Heg, Dik
    Roffi, Marco
    Tuller, David
    Vuilliomenet, Andre
    Muller, Olivier
    Cook, Stephane
    Weilenmann, Daniel
    Kaiser, Christoph
    Jamshidi, Peiman
    Khattab, Ahmed A.
    Taniwaki, Masanori
    Rigamonti, Fabio
    Nietlispach, Fabian
    Blochlinger, Stefan
    Wenaweser, Peter
    Juni, Peter
    Windecker, Stephan
    EUROINTERVENTION, 2016, 12 (11) : E1343 - E1354
  • [37] Biodegradable polymer drug eluting stents versus durable polymer drug eluting stents for percutaneous coronary intervention
    Kheifets, M.
    Levi, A.
    Bental, T.
    Perl, L.
    Codner, P.
    Wittberg, G.
    Talmor-Barkan, Y.
    Landes, U.
    Samara, A.
    Greenberg, G.
    Erez, A.
    Vaknin-Assa, H.
    Kornowski, R.
    EUROPEAN HEART JOURNAL, 2021, 42 : 2137 - 2137
  • [38] Effectiveness of a novel biodegradable polymer, sirolimus-eluting stent platform in percutaneous coronary intervention
    Dominici, Marcello
    Arrivi, Alessio
    Bazzucchi, Marco
    De Paolis, Marcella
    Milici, Caterina
    Bock, Carlo
    Placanica, Attilio
    Lazzari, Ludovico
    Diletti, Roberto
    Boschetti, Enrico
    MINERVA CARDIOANGIOLOGICA, 2016, 64 (01): : 1 - 8
  • [39] Coronary aneurysm formation following biodegradable polymer drug-eluting stent implantation
    Zhang, Feng
    Qian, Juying
    Dong, Lili
    Ge, Junbo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 160 (01) : E8 - E9
  • [40] Comparison of a Novel Biodegradable Polymer Sirolimus-Eluting Stent With a Durable Polymer Everolimus-Eluting Stent: A Systematic Review and Meta-Analysis
    Khalid, Yaser
    Dasu, Neethi
    Dasu, Kirti
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B115 - B116