High voltage power supply for steady state operation of the neutral beam test facility ELISE

被引:4
|
作者
Peglau, Matthias [1 ]
Schmidt, Alexander Benjamin [1 ]
Koerner, Frederik [1 ]
Fantz, Ursel [1 ]
Heinemann, Bernd [1 ]
Haindl, Christoph [1 ]
Kaesemann, Claus-Peter [1 ]
Oswald, Alexander [1 ]
Riedl, Rudolf [1 ]
Wuenderlich, Dirk [1 ]
机构
[1] Max Planck Inst Plasma Phys, Boltzmannstr 2, D-85748 Garching, Germany
关键词
High voltage dc power supply; IGBT; Pulse step modulation; PSM; Neutral beam injection; ELISE; Negative ion source;
D O I
10.1016/j.fusengdes.2022.113382
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The Neutral Beam Injection (NBI) system of ITER shall provide 33 MW heating power to the plasma for up to one hour by two injectors. The beam lines will be based on large RF-driven sources for negative hydrogen or deuterium ions. The test facility ELISE (Extraction from a Large Ion Source Experiment) at IPP Garching is supporting the ion source development for ITER with an ion source of 1 x 1 m(2) (half the size of the ITER source). While plasma operation of ELISE is possible for up to one hour, the extraction and acceleration of a negative ion beam (up to 60 kV) was initially possible only for X10 s every X150 s with the old power supply. During such pulses the temporal behavior of the co-extracted electrons significantly depends on whether beam extraction is switched on or off. Thus, continuous wave (CW) extraction is mandatory for developing fully ITER relevant operational scenarios and recently, a steady state power supply for beam extraction has been installed at ELISE. This power supply consists of two stages connected in series: a first stage with 12 kV / 70 A, providing 35 A for the extracted negative ion current, with a 35 A overhead for co-extracted electrons. The second stage of 50 kV / 35 A is used for the further acceleration of only the ions to a total potential of 60 kV. The two stages have an electrical active power of 1.75 MW and 0.84 MW respectively. The power supply operates with pulse step modulation. Bipolar transistors with insulated gate electrodes (IGBT) are used as electrical switches on the DC side. The 50 kV stage consists of 64 modules in series and the 12 kV stage has 24 modules. Both stages are controlled synchronously and must detect breakdowns between the grids in a mu s range.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Toward a Large RF Ion Source for the ITER Neutral Beam Injector: Overview of the ELISE Test Facility and First Results
    Nocentini, Riccardo
    Fantz, Ursel
    Franzen, Peter
    Froeschle, Markus
    Heinemann, Bernd
    Riedl, Rudolf
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2014, 42 (03) : 616 - 623
  • [22] ITER-relevant 600 s steady-state extraction of negative hydrogen ions at the test facility ELISE
    Wuenderlich, D.
    Riedl, R.
    Froeschle, M.
    Heiler, A.
    Navarro, A.
    Yordanov, D.
    Doering, A.
    Fantz, U.
    NUCLEAR FUSION, 2025, 65 (01)
  • [23] Steady state operation of high power gyrotron for ITER
    Kasugai, Atsushi
    Kajiwara, Ken
    Takahashi, Koji
    Kobayashi, Noriyuki
    Kariya, Tsuyoshi
    Mitsunaka, Yoshika
    Sakamoto, Keishi
    EIGHTH IEEE INTERNATIONAL VACUUM ELECTRONICS CONFERENCE, 2007, : 37 - +
  • [24] Diagnostics and steady-state high power operation
    Laviron, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 1770 - 1772
  • [25] The neutral beam test facility cryopumping operation: Preliminary analysis and design of the cryogenic system
    Gravil, B.
    Henry, D.
    Dremel, M.
    Cordier, J. J.
    Hemsworth, R.
    Van Houtte, D.
    ICEC 20: PROCEEDINGS OF THE TWENTIETH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE, 2005, : 31 - 34
  • [26] Influence of the magnetic filter field topology on the beam divergence at the ELISE test facility
    Barbisan, M.
    Fantz, U.
    Wuenderlich, D.
    FIFTH INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2016), 2017, 1869
  • [27] A high-voltage power supply of the diagnostic neutral beam injector of the Alcator-Cmod tokamak
    Kolmogorov, V. V.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2009, 52 (06) : 829 - 836
  • [28] A high-voltage power supply of the diagnostic neutral beam injector of the Alcator-Cmod tokamak
    V. V. Kolmogorov
    Instruments and Experimental Techniques, 2009, 52 : 829 - 836
  • [29] The High Voltage Power Supply System for the European 2MW Electron Cyclotron Test Facility
    Bonicelli, T.
    Albajar, F.
    Fasel, D.
    Rinaldi, L.
    Siravo, U.
    Sita, L.
    Taddia, G.
    EPE: 2009 13TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-9, 2009, : 5926 - 5935
  • [30] Beam diagnostic tools for the negative hydrogen ion source test facility ELISE
    Nocentini, Riccardo
    Fantz, Ursel
    Franzen, Peter
    Froeschle, Markus
    Heinemann, Bernd
    Riedl, Rudolf
    Ruf, Benjamin
    Wuenderlich, Dirk
    FUSION ENGINEERING AND DESIGN, 2013, 88 (6-8) : 913 - 917