Simulation of Leksell Gamma Knife-4C System with Different Phantoms Using PHITS and Geant4

被引:0
|
作者
Hung, B. T. [1 ]
Duong, T. T. [2 ]
Ha, B. N. [2 ]
机构
[1] Vietnam Atom Energy Inst, 59 Ly Thuong Kiet, Hanoi, Vietnam
[2] Univ Sci & Technol, 1 Dai Co Viet, Hanoi, Vietnam
关键词
Leksell gamma knife; Reference computational phantoms; PHITS; Geant4; MODEL;
D O I
10.55981/aij.2023.1266
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This study used PHITS and Geant4 code packages to simulate a Leksell Gamma Knife system in order to determine radiation dose distribution in two types of phantoms. The results observed in the water phantom with configurations of single source and 201 sources are in good accord with the prior research, including both simulation and experiment. Several characteristics of Leksell Gamma Knife 4C, such as dose profiles, output factor, FWHM, and penumbra size, are calculated based on Monte Carlo simulations, which show the best consistency with other results. The output factors for collimators of 14 mm, 8 mm, and 4 mm are 0.984, 0.949, and 0.872, respectively. The simulation results with an adult mesh-type reference phantom reveal considerable similarities with the established radiosurgery plans. It indicates that the absorbed dose in brain tumors was highest when utilizing the 18 mm collimator and subsequently reduced with collimator size to 0.65, 0.25, and 0.5 with the 14 mm, 8 mm, and 4 mm collimators, respectively. The absorbed dose has a very low value for other essential organs and decreases with distance from the brain tumor. These findings may explain why the dose to organs decreases linearly as target distance, volume, and collimator size increase.(c) 2023 Atom Indonesia. All rights reserved
引用
下载
收藏
页码:13 / 20
页数:8
相关论文
共 50 条
  • [21] Study of proton computed tomography using GEANT4 simulation
    Aso, Tsukasa
    Fujisaka, Katsuhiko
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 876 - 879
  • [22] Three Dimensional Simulation of ITER Machine by Using Geant4
    Mohammad Mehdi Nasseri
    Journal of Fusion Energy, 2016, 35 : 621 - 625
  • [23] ARGO-YBJ detector simulation using GEANT4
    Guo Yi-Qing
    Zhang Xue-Yao
    Zhang Jian-Li
    Hu Hong-Bo
    Zha Min
    He Hui-Hai
    Feng Zhao-Yang
    Wu Chao-Yong
    Wang Bo
    Zhang Yi
    Surdo, A.
    Lu Hong
    CHINESE PHYSICS C, 2010, 34 (05) : 555 - 559
  • [24] Simulation of the response of a PIPS detector using GEANT4 code
    Diaz-Frances, J. A.
    Cortes-Giraldo, M. A.
    Jimenez-Ramos, M. C.
    Hurtado-Bermudez, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 875 : 21 - 26
  • [25] Three Dimensional Simulation of ITER Machine by Using Geant4
    Nasseri, Mohammad Mehdi
    JOURNAL OF FUSION ENERGY, 2016, 35 (04) : 621 - 625
  • [26] ARGO-YBJ detector simulation using GEANT4
    郭义庆
    张学尧
    张建立
    胡红波
    查敏
    何会海
    冯朝阳
    吴超勇
    王博
    张毅
    A. Surdo
    卢红
    Chinese Physics C, 2010, 34 (05) : 555 - 559
  • [27] Diagrams for the Leksell Gamma Knife 4C automatic positioning system accessible shot coordinates
    Watanabe Y.
    Radiological Physics and Technology, 2013, 6 (1) : 197 - 201
  • [28] Simulation study for a single TOF scintillator using GEANT4
    Zhang, LM
    Peng, HP
    Zhang, ZP
    Chen, HF
    Shao, M
    Wu, J
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (07) : N54 - N57
  • [29] Monte Carlo simulation of the ELIMED beamline using Geant4
    Pipek, J.
    Romano, F.
    Milluzzo, G.
    Cirrone, G. A. P.
    Cuttone, G.
    Amico, A. G.
    Margarone, D.
    Larosa, G.
    Leanza, R.
    Petringa, G.
    Schillaci, F.
    Scuderi, V.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [30] Comparison of MC Geant4 simulation with the measurements of gamma photons produced by neutrons
    Kasztelan, M.
    Jedrzejczak, K.
    Szabelski, J.
    MODERN PHYSICS LETTERS A, 2019, 34 (06)