摘要
We have developed a graphic representation (APS shot-range diagrams) of achievable shot coordinates with the automatic positioning system (APS) for Gamma Knife stereotactic radiosurgery. We formulated a mathematical relationship between the APS coordinate system and the Leksell frame coordinate system (frame-system) by considering the relative translation and rotation. Using the transformation equations, we calculated the Y-Z coordinate domain in the frame-system (domain B), which corresponds to the known coordinate domain achievable in the APS coordinate system (domain A). APS shot-range diagrams were presented by overlaying of domain B over domain A so that one can easily visualize the achievable shot coordinates with APS for various gamma angles. Domains A and B are identical for a 90 gamma angle, but they are different for other gamma angles. Applications of the diagrams to clinical cases, in which Leksell GammaPlan treatment planning software automatically set some of the shots in a treatment plan as trunnion shots because of the APS coordinate limit, enabled us to avoid the trunnion shots, and consequently to achieve much faster treatment delivery. In conclusion, APS shot-range diagrams can be used for achieving more efficient treatment delivery by avoiding unnecessary trunnion shots with a Gamma Knife unit equipped with the APS. © 2012 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:197 / 201
页数:4
相关论文
共 36 条
  • [1] Risk analysis of Leksell Gamma Knife Model C with Automatic Positioning System
    Goetsch, SJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (03): : 869 - 877
  • [2] Dosimetric comparison of the Leksell Gamma Knife Perfexion and 4C
    Novotny, Josef, Jr.
    Bhatnagar, Jagdish P.
    Niranjan, Ajay
    Quader, Mubina A.
    Huq, M. Saiful
    Bednarz, Greg
    Flickinger, John C.
    Kondziolka, Douglas
    Lunsford, L. Dade
    JOURNAL OF NEUROSURGERY, 2008, 109 : 8 - 14
  • [3] A comparison of the gamma knife model C and the automatic positioning system with Leksell model B
    Tlachacova, D
    Schmitt, M
    Novotny, J
    Novotny, J
    Majali, M
    Liscak, R
    JOURNAL OF NEUROSURGERY, 2005, 102 : 25 - 28
  • [4] Practical quality assurance of the automatic positioning system on the Leksell Gamma Knife
    Lerma, F
    Drzymala, RE
    MEDICAL PHYSICS, 2003, 30 (06) : 1363 - 1363
  • [5] Improved patient treatment with Leksell Gamma Knife automatic positioning system
    Goetsch, S.
    MEDICAL PHYSICS, 2007, 34 (06) : 2459 - 2459
  • [6] The commissioning and quality assurance of the Automatic Positioning System on the Leksell gamma knife
    Soanes, T
    Hampshire, A
    Vaughan, P
    Brownett, C
    Rowe, J
    Radatz, M
    Kemeny, A
    Walton, L
    JOURNAL OF NEUROSURGERY, 2002, 97 : 574 - 578
  • [7] Dosimetrical evaluation of Leksell Gamma Knife 4C radiosurgery unit
    Sajeev, Thomas
    Mustafa, Mohamed M.
    Supe, Sanjay S.
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2011, 17 (03) : 105 - 120
  • [8] First clinical experience with the automatic positioning system and Leksell gamma knife Model C -: Technical note
    Horstmann, GA
    Schöpgens, H
    van Eck, ATCJ
    Kreiner, HJ
    Herz, W
    JOURNAL OF NEUROSURGERY, 2000, 93 : 193 - 197
  • [9] Stereotactic radiosurgery of essential trigeminal neuralgia using Leksell Gamma Knife model C with automatic positioning system
    Hayashi, Motohiro
    Chernov, Mikhail
    Tamura, Noriko
    Taira, Takaomi
    Izawa, Masahiro
    Yomo, Shoji
    Nagai, Mariko
    Chang, Cheng-Siu
    Ivanov, Pavel
    Tamura, Manabu
    Muragaki, Yoshihiro
    Okada, Yoshikazu
    Iseki, Hiroshi
    Takakura, Kintomo
    NEUROSURGICAL REVIEW, 2011, 34 (04) : 497 - 508
  • [10] Efficiency and Dose Planning Comparisons between the Perfexion and 4C Leksell Gamma Knife Units
    Niranjan, Ajay
    Novotny, Josef, Jr.
    Bhatnagar, Jagdish
    Flickinger, John C.
    Kondziolka, Douglas
    Lunsford, L. Dade
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2009, 87 (03) : 191 - 198